Retrofit instructions Nozzle changer SIPLACE H F-series C&P head 12/2004 Edition 17 2 Retrofit instructions SIPLACE HF-series nozzle change r C&P head 2.1 Part s required 2.1.1 T ools and consumables required Set…
Nachrüstanleitung Pipettenwechsler Collect&Place-Bestückkopf SIPLACE HF-Serie
Ausgabe 12/2004
16

Retrofit instructions Nozzle changer SIPLACE HF-series C&P head
12/2004 Edition
17
2 Retrofit instructions SIPLACE HF-series nozzle
changer C&P head
2.1 Parts required
2.1.1 Tools and consumables required
Set of hexagon socket spanners 2
Set of diagonal cutters 2
Hammer 2
2.2 Possible nozzle changer configurations
2
2
2
2
If the NC are prepared for both C&P 12 and C&P 6, the following configuration is possible: 2
2
2
C+P 12 head
HF nozzle changer, 12-segment C+P head 00119661-01
HF nozzle changer 2, 12-segment C+P head 00119663-01
C+P 6 head
HF nozzle changer, 6-segment C+P head 00119662-01
HF nozzle changer 2, 6-segment C+P head 00119664-01
From SW 504
Location 1 Row 1 for original equipment 00119661-01 for original equipment 00119662-01
Row 2 Expansion 1 00119663-01 Expansion 1 00119664-01
Location 4 Row 1 Expansion 2 00119663-01 Expansion 2 00119664-01
SW 504
Location 1 Row 1 for original equipment 00119661-01 C&P 12 head
Row 2 Expansion 1 00119664-01 C&P 6 head
Location 4 Row 1 Expansion 2 00119663-01 or 00119664-01 C&P 12 or C&P 6 heads

Retrofit instructions Nozzle changer SIPLACE HF-series C&P head
18
2.3 Safety instructions
WARNING
Comply with the higher ranking "Safety Instructions" in Chapter "Operational Safety" in the User
Manual and Service Manual
The placement machines SIPLACE are powered by mains voltage.
Portions of the system are therefore conducting dangerous electricity, inside the machine even
while the master switch is turned off.
Death, serious injury or considerable damage may result if these automatic placement systems
are handled incorrectly.
After you have properly carried out the shut-down of the operating system:
Before all work the machine must be turned off at the main switch and isolated from the mains. In
addition, the compressed air supply must be turned off at the main valve of the compressed air
unit in the machine base and the compressed air lines must be bled by actuating the needle valve
at the compressed air unit.
Danger: For anyone wearing a heart pacemaker it is not permitted to work near linear motors, as
described in detail in the User Manual and the Service Manual, Chapter "Special Safety Instruc-
tions when working in vivinty of powerful magnetic fields" .
Obey the applicable accident prevention regulations, DIN standards and special safety codes of
your country at all times. DIN EN 60204 must be adhered to during all work inside the machine
base.
Follow the instructions regarding residual voltages in Chapter "Operational Safety".
Comply with regulations on ESDs (see Chapter "Operational Safety").
During the work of retrofitting secure the machine conscientiously against other personnel and
prevent it from being turned back on without authorization, as described in the User Manual in the
chapter "Locking the Machine...".
There is additional, higher risk of accident when working with the SITEST program.
The SITEST program is only to be started by personnel who are authorized to do so. 2
2
2.3.1 Definitions
2
Please note 2