Assembly instructions MTC2 and Component docking unit on SIPLACE HF and X-se ries Edition 07/2009 134 : Check for horizont al alignment on the MTC with a spirit level. 2 Fig. 2.12.2 T op view: MTC alignment 2 : Secure th…

100%1 / 146
Assembly instructions MTC2 and Component docking unit on SIPLACE HF and X-series
Edition 07/2009
133
2.12 Docking of the MTC2
: Check the height of the MTC2.
It must have the same height as the place
ment machine.
2
The height is indicated in the small window below the cover under the door of tower 1
(830 / 900 / 930 / 950 ± 15 mm).
2
: If it does not have the same height as the placement machine, adjust the MTC to the machine
height and then dock it to the machine.
2
For further information, see operating instructions of MTC2:
00193634- Operating instructions SIPLACE MTC2
00193635- User Manual SIPLACE MTC2 2
2
The MTC must not be higher than the clamping edges of the PCB conveyor. 2
2
2
Fig. 2.12.1 The height of the MTC must be adjusted to the PCB conveyor.
2
2
2
Assembly instructions MTC2 and Component docking unit on SIPLACE HF and X-series
Edition 07/2009
134
: Check for horizontal alignment on the MTC with a spirit level.
2
Fig. 2.12.2 Top view: MTC alignment
2
: Secure the MTC in the machine.
2
2
2
2
Assembly instructions MTC2 and Component docking unit on SIPLACE HF and X-series
Edition 07/2009
135
2.13 Using the MTC with the CPP placement head
: Read the "Head Reconfiguration CPP" assembly instructions, if necessary (item no.:
00196428-xx).
2
With the MTC, the placement head must only be fitted in the top position. The installation height
is monitored during the head reference run.
In software version 702, the CPP head is not appro
ved for a 2-gantry placement area with
MTC. In this case there is no nozzle changer available at the location with MTC.
Crash risk: Wh
en the CPP head is used with the MTC, the travel range must also be re-
stricted. You should therefore fit 2x the extens
ion for the Y axis stop (item no.: 03075963-01
"Adaptation, Y axis stop, MTC“). These are included in the package as a precautionary mea-
sure.
Standard stop
Stop withMTC