00197733-01_VD_605_04_DE_EN - 第10页
Station Software 60 5.04 / Version D escription Ausgabe 04/ 2015 Edition 10 4.3 Supported H ardware Options w ith an Interface to the 605.0 4 S tation Software Feature X4 X3 X2 D1/ D1i D2/ D2i D3 D4/ D4i Additional infor…
Station Software 605.04 / Version Description Ausgabe 04/2015 Edition
9
4 Features of the 605.04 Station Software Version
If not differently described, the features of the 601.xx – 605.03 SP5 station software versions are
also supported by the 605.04 station software version. The main features of the 605.04 station
software version are listed below.
Detailed information about the functions can be found in the online help for the station software.
4.1 Operating System Windows 7
As of this station software version, only the Windows 7 operating system is supported on the
station computer and Vision computer (see "Installation Manual Operating System Windows
Embedded Standard 7", item number [00197737-xx] and the Installation Manual to the station
software, item no. [00197734-xx]).
In Windows 7 the station computer has to be equipped with at least 2 GB memory. If necessary,
station computers in the field have to be exchanged or upgraded with a memory extension. Please
refer to the Technical Information TI2014-09E04.
4.2 Opening SIPLACE Vision Measurement Context Files
SIPLACE Vision measurement context files that have been created on a placement machine with
the 605.04 station software version can only be opened with Vision Teach Station as of the 5.1.2
version.

Station Software 605.04 / Version Description Ausgabe 04/2015 Edition
10
4.3 Supported Hardware Options with an Interface to the 605.04 Station Software
Feature X4 X3 X2 D1/
D1i
D2/
D2i
D3 D4/
D4i
Additional information
RF and PDA MC70 scanner
Can be used on all X- and D-series
machines, the MTC 2 and the
SIPLACE Setup Center 3.3.
Sensor for reject bin
Sensor for verifying that the reject bin
has been mounted correctly in order to
prevent potential head crashes
(particularly recommended if C&P20
heads are used).
2D PCB barcode reader
"2 D Barcode" (hardware) option
required
MTC 2 For restrictions, see chapter 9
"WPC 4" waffle pack changer For restrictions, see chapter 9
Manual tray For restrictions, see chapter 9
Component reject conveyor For restrictions, see chapter 9
Dip module
Cannot be used on component
changeover tables of the X-series.
Dip module for X-tables (LDU_X) For restrictions, see chapter 9
Coplanarity module with 3D coplanarity
sensor
For restrictions, see chapter 9
X feeder adapter for linear feeders For restrictions, see chapter 9

Station Software 605.04 / Version Description Ausgabe 04/2015 Edition
11
Productivity lift
PCB width restricted to 216 mm with a
dual conveyor and to 460 mm with a
single conveyor.
Maximum permitted component height,
13 mm.
Cannot be used in combination with an
MTC2 at location 4 of an X2.
WDTL is not possible.
Vacuum tool
The station software offers no
possibility to configure the type of the
vacuum tool.
Table 4-1: Supported hardware options