00197733-01_VD_605_04_DE_EN - 第11页

Station Software 60 5.04 / Version D escription Ausgabe 04/ 2015 Edition 11 Productivity lift        PCB width restricted to 216 mm with a dual conveyor and t o 460 mm with a single conveyor. Maximum perm itted co…

100%1 / 76
Station Software 605.04 / Version Description Ausgabe 04/2015 Edition
10
4.3 Supported Hardware Options with an Interface to the 605.04 Station Software
Feature X4 X3 X2 D1/
D1i
D2/
D2i
D3 D4/
D4i
Additional information
RF and PDA MC70 scanner
Can be used on all X- and D-series
machines, the MTC 2 and the
SIPLACE Setup Center 3.3.
Sensor for reject bin
Sensor for verifying that the reject bin
has been mounted correctly in order to
prevent potential head crashes
(particularly recommended if C&P20
heads are used).
2D PCB barcode reader
"2 D Barcode" (hardware) option
required
MTC 2 For restrictions, see chapter 9
"WPC 4" waffle pack changer For restrictions, see chapter 9
Manual tray For restrictions, see chapter 9
Component reject conveyor For restrictions, see chapter 9
Dip module
Cannot be used on component
changeover tables of the X-series.
Dip module for X-tables (LDU_X) For restrictions, see chapter 9
Coplanarity module with 3D coplanarity
sensor
For restrictions, see chapter 9
X feeder adapter for linear feeders For restrictions, see chapter 9
Station Software 605.04 / Version Description Ausgabe 04/2015 Edition
11
Productivity lift
PCB width restricted to 216 mm with a
dual conveyor and to 460 mm with a
single conveyor.
Maximum permitted component height,
13 mm.
Cannot be used in combination with an
MTC2 at location 4 of an X2.
WDTL is not possible.
Vacuum tool
The station software offers no
possibility to configure the type of the
vacuum tool.
Table 4-1: Supported hardware options
Station Software 605.04 / Version Description Ausgabe 04/2015 Edition
12
5 SITEST
SITEST Version 605.xx incorporates all the functions for testing and setting the components of the
X- and D-series machines.
NOTICE
For a detailed description of the functions of SITEST, please refer to the online help
system for SITEST.
The following changes have been made in SITEST for software version 605:
You can set-up the conveyor widths to ensure the compatibility to the SIPLACE X4i machines.
As a service engineer you can set the position of the fixed conveyor side user-defined in the
Options and Configurations menu. The settings apply to the conveyor, not for the track.
In the Options – Nozzle scan options menu you can configure the nozzle scan concerning
the closeness of the nozzle scan and the behavior of the machine in case of defects.
Second row nozzle changer supported for D4 machines (also valid for D4i machines).