00197733-01_VD_605_04_DE_EN - 第13页
Station Software 60 5.04 / Version D escription Ausgabe 04/ 2015 Edition 13 6 Service Tools 6.1 Automatic Er ror Report (Bug Repo rt) The "BugReporter" tool is used to autom atically save all the data required …

Station Software 605.04 / Version Description Ausgabe 04/2015 Edition
12
5 SITEST
SITEST Version 605.xx incorporates all the functions for testing and setting the components of the
X- and D-series machines.
NOTICE
For a detailed description of the functions of SITEST, please refer to the online help
system for SITEST.
The following changes have been made in SITEST for software version 605:
– You can set-up the conveyor widths to ensure the compatibility to the SIPLACE X4i machines.
– As a service engineer you can set the position of the fixed conveyor side user-defined in the
Options and Configurations menu. The settings apply to the conveyor, not for the track.
– In the Options – Nozzle scan options menu you can configure the nozzle scan concerning
the closeness of the nozzle scan and the behavior of the machine in case of defects.
– Second row nozzle changer supported for D4 machines (also valid for D4i machines).

Station Software 605.04 / Version Description Ausgabe 04/2015 Edition
13
6 Service Tools
6.1 Automatic Error Report (Bug Report)
The "BugReporter" tool is used to automatically save all the data required for debugging in an error
report (bug report) each time the station is shut down. The "BugReporter" tool must be activated to
do this.
Activating the "BugReporter" tool:
► Double-click the BugReporter_Autrun_ON.reg file in the folder C:\WinBO folder.
► Then confirm the two dialog boxes which appear by clicking OK.
Deactivating the "BugReporter" tool:
► Double-click the BugReporter_Autrun_OFF.reg filed in the folder C:\WinBO folder.
► Then confirm the two dialog boxes which appear by clicking OK.
After the "BugReporter" tool has been activated, the "BugReporter" tool dialog box appears
automatically each time that the station is shut down. It is not possible to make any entries. The
fields are completed automatically.
The current error report is stored under C:\BugReport\Latest. Previous error reports are stored
under C:\BugReport\Archive. Since the Latest and Archive folders also contain the error reports
created manually by pressing ALT + CTRL + F10, the automatically generated error reports are
indicated by AutoLog_xxxxxxxxxx_x.zip in the file name. An error report can comprise several
files. If this is the case, the number in the file name is incremented automatically (e.g.
AutoLog_xxxxxxxxxx_2.zip).
6.1.1 Restrictions
When the "BugReporter" is activated, it may take up to 3 minutes longer to shut down the station.

Station Software 605.04 / Version Description Ausgabe 04/2015 Edition
14
6.2 "ROC" for Reading Out the Configuration Data of the Station
The "ROC" tool (Readout Station Configuration) is used to optimize the remote service (e.g. for
trouble shooting and compatibility checks).
The following information can be read out by the tool:
– Operation system (version, build, service pack)
– Language Pack
– Station software (version, release, build, patch, service pack, hotfix)
– Version of the firmware of the components which are able to download from SITEST (e.g. axis
cards, vision, pcb transport, cameras, WPC, feeder table)
– Machine identification
– Machine typ (e.g. D1 machine)
– IP addresses
– Head configuration
– SIPLACE options (e.g. nozzle changer, vacuum pump, high components, whispering)
Start the tool as described:
► Stop the machine.
► Change to the desktop.
► Start the ROC.exe application from the desktop.
The following dialog is displayed:
Figure 6-1: "ROC" dialog
► Click on the Create Configuration Status File button.
The configuration data is written to the ConfigStatus.xml file.