Station Software 60 5.04 / Version D escription Ausgabe 04/ 2015 Edition 31 Automatic pitch do wnload on S feeders – Surftape feeders a re not supported. – Feeders on X feeder ad apter are not support ed. – No check of t…
Station Software 605.04 / Version Description Ausgabe 04/2015 Edition
30
"Long PCB" option
– The "Long PCB" option is not supported on a SIPLACE D1 / D1i machine for placing
components higher than 8 mm. Higher components that were placed at the first stop unit could
lead to mechanical damage to the C&P head or incorrect placement at the second stop unit as
a result of interference boundaries.
– "Long PCB" option is not supported in combination with flexible dual conveyor.
Teaching/Changing the component shape
– Not released for barcode applications.
Changing the X feeder position
– Not released for barcode applications.
– The new feeder type must be an X feeder (8-88mm).
– The new position (track number) must be on the same table.
Auto recovery and manual recovery
– Not released for barcode applications.
– The "Auto recovery" and "Manual recovery" options must be activated.
Omitting components
– Not released for barcode applications.
– The "Auto recovery" and "Manual recovery" options must be activated.
Placement of 01005 components
– The sleeve is not recognized automatically.
– The nozzle peak position is not calculated and corrected.
– Only for C&P12 and C&P20 heads, the functionality is not supported for C&P6 heads.
– Special sleeves and special nozzles are necessary for C&P12 heads.
– On D4 / D4i machines, the placement of 01005 components is only possible on the placement
area 1.
– The feeders can only be set on the first 6 positions to the gantry root.
– The size of the boards is restricted to 230mm.
– The placement capacity will be reduced for approx. 22%.

Station Software 605.04 / Version Description Ausgabe 04/2015 Edition
31
Automatic pitch download on S feeders
– Surftape feeders are not supported.
– Feeders on X feeder adapter are not supported.
– No check of the current pitch. The pitch is set when the setup job is downloaded. If you replace
the feeder, the new feeder does not assume the current pitch value of SIPLACE Pro.
– The software does not detect if you change manually the pitch values on the feeder.
– The manual pitch download can only be performed table-wise, not feeder-wise.
– The automatic pitch download is also performed if the feeder is in the current setup but not
used in the current job.
– The manual pitch download button is always activated if there is any feeder in the setup for the
respective table even no S-Feeder is set.
– Supported feeders and the restrictions see software version description 604.01,
item no. [00195445-xx].
LDU_X dip module for X-tables
– The number of LDU_X dip modules per head is limited to one.
– The number of LDU_X dip modules per X4 machine is limited to four.
– Setup verification is not possible.
– The "Correct position" function is not available for the LDU_X dip module.
– For C&P 6/12 heads only "Dipping before Vision" is supported.
– Dipping with the C&P20 head is currently not supported.
– The area that effectively is usable for dipping components is given by SIPLACE Pro
– LDU_X dip modules cannot be placed on any track of the X table because of restrictions
concerning the accessibility with the twin head. The range of usable tracks for setting up
LDU_X dip modules is limited in SIPLACE Pro.
– If the medium in the flux reservoir is not sufficient, no message will be displayed. The display of
the level is currently not supported for the LDU_X dip module.
– The table provides an overview for which machines and placement heads the LDU_X dip
module can be used:
Twin Head C&P 6/12 C&P20 P&P
X-series (S-feeder) No No No No
X-series (X-feeder) Yes Yes No No
Emergency stop during automatic width adjustment
If an emergency stop is performed during the automatic width adjustment, the width is not correct
anymore. The desired width has to be redefined in the Manual Operations. Thereafter, it is set and
the production can be restarted.
Counting panels
When using dual lane conveyor, the total quantity of placed panels is assigned to the right board
and the left board gets a zero.

Station Software 605.04 / Version Description Ausgabe 04/2015 Edition
32
10 Corrected Errors
The 605.04 station software version contains all error corrections of the previous versions
601.xx – 605.03 SP5.
NOTICE
Information can be found in the "Errors that have been eliminated" or "Corrected errors"
chapter of the corresponding version descriptions.
Additionally, the following errors have been corrected in this version:
Error no. Error description
D1-100454201 Sporadically, the TH z-axis did not move up.
D1-102126615 If an arbitrary tray was empty the operator scanned refill with new UniqueID but the
quantity was set to zero by the station.
D1-103246641 The nozzle scan was too sensitive for the 4108 and 4109 nozzles.
D1-104096501 The software hung up at station stop caused by to the Station Stop command
issued by OIB.
D1-104633807 The TH z-axis remained for appr. 30 seconds in the "empty" tape pocket.
D1-106208068 Vision error at gantry 2 with TH. After teaching and track release, the gantry moved
to track 27 and not to track 33 on which the component was present.
D1-106261701
D1-107296732
D1-108367111
D1-108476601
The software often hung up after a hotfix upgrade.
D1-111479401 Incorrect error message "Fiducial error".
D1-85476401 The nozzle could not be changed.
D1-93962501 Indistinct error description for defective component sensor at the nozzle changer.
D1-96024201 The software hung up without error message.
D1-96338032 The software hung up during component placement.
D1-97678901 Too small clearance over the LDU_SWS dip module in the waiting position of the
C&P20 placement head.
D16804-10507
D16804-12207
D16804-16207
D16877-16322
D17257-10209
D17257-10460
D17257-10707
The software hung up when the component pickup position was taught (due to too
high task IDs).
D16804-15308 The machine stopped after the operator had refilled the WPC.