00197733-01_VD_605_04_DE_EN - 第33页

Station Software 60 5.04 / Version D escription Ausgabe 04/ 2015 Edition 33 D16877 - 14914 D 16877 - 17001 D17257 - 10607 D17307 - 5401 D17307 - 5501 D17349 - 11234 D17382 - 10807 D16834 - 7107 The software hung u p duri…

100%1 / 76
Station Software 605.04 / Version Description Ausgabe 04/2015 Edition
32
10 Corrected Errors
The 605.04 station software version contains all error corrections of the previous versions
601.xx 605.03 SP5.
NOTICE
Information can be found in the "Errors that have been eliminated" or "Corrected errors"
chapter of the corresponding version descriptions.
Additionally, the following errors have been corrected in this version:
Error no. Error description
D1-100454201 Sporadically, the TH z-axis did not move up.
D1-102126615 If an arbitrary tray was empty the operator scanned refill with new UniqueID but the
quantity was set to zero by the station.
D1-103246641 The nozzle scan was too sensitive for the 4108 and 4109 nozzles.
D1-104096501 The software hung up at station stop caused by to the Station Stop command
issued by OIB.
D1-104633807 The TH z-axis remained for appr. 30 seconds in the "empty" tape pocket.
D1-106208068 Vision error at gantry 2 with TH. After teaching and track release, the gantry moved
to track 27 and not to track 33 on which the component was present.
D1-106261701
D1-107296732
D1-108367111
D1-108476601
The software often hung up after a hotfix upgrade.
D1-111479401 Incorrect error message "Fiducial error".
D1-85476401 The nozzle could not be changed.
D1-93962501 Indistinct error description for defective component sensor at the nozzle changer.
D1-96024201 The software hung up without error message.
D1-96338032 The software hung up during component placement.
D1-97678901 Too small clearance over the LDU_SWS dip module in the waiting position of the
C&P20 placement head.
D16804-10507
D16804-12207
D16804-16207
D16877-16322
D17257-10209
D17257-10460
D17257-10707
The software hung up when the component pickup position was taught (due to too
high task IDs).
D16804-15308 The machine stopped after the operator had refilled the WPC.
Station Software 605.04 / Version Description Ausgabe 04/2015 Edition
33
D16877-14914
D16877-17001
D17257-10607
D17307-5401
D17307-5501
D17349-11234
D17382-10807
D16834-7107
The software hung up during placement, especially when components were
omitted.
D17241-11201 On a D4 machine, the gantry reference run and the nozzle scan failed (problem
with component sensor).
D17310-5307 The software hung up after downloading the program.
D17310-5516 When the RV/Z axis: axis does not reach required position error
was reported there was no information about the affected segment.
D17349-8516 The station software GUI closed during production.
D17450-2811
D17522-3313
The machine stopped during placement.
D17667-2941 The machine hung up after the processed board was aborted and had to be
restarted.
D17807-2463 On a D1i placement machine, an MC exception error occurred and the machine
had to be restarted.
Table 10-1: Corrected errors
Station Software 605.04 / Version Description Ausgabe 04/2015 Edition
34
11 Appendix: Validity of the Settable Machine Options
The individual machine options can be set in the Options – Machine option menu. You require
the access level "Line engineer" or "Service engineer" to change the machine options.
A detailed description of the machine options can be found in the online help system of the station
software.
Machine option Validity
Process PCB conv. 1/2 These settings are automatically
activated for every new job.
Ink spot check
PCB position recognition
Feeder position recogn. These settings are also valid after job
changes and after the machine has
been switched off.
Comp. verification with barcode
Confirm PCB following emerg. stop
Confirm PCB when inspection is required
MTC or WPC x: FIFO component pickup strategy
S feeder: No pitch download
Error inspection in processing area
Prepick active
PCB data transfer These settings are provided via
SIPLACE Pro for every new job.
Optical component centering 1
Component sensor on head x
Without 3D senso
Input conveyor locked This setting is also valid at a machine
reboot.