5 Pneumatic System 5.8 Replacing the proportional controller (Location 4) Service Manual SIPLACE X-Serie S 06/2019 139 5.8 Replacing the proportional controller (Location 4) Parts, equipment and tools Fig.171: Proportio…

100%1 / 428
5 Pneumatic System
5.7 Replacing the pneumatics assembly at location 1
138 Service Manual SIPLACE X-Serie S 06/2019
Fig.170: Pressure regulator
Remove the three screws(2) fastening
the pneumatics assembly(1).
Unplug all electrical and pneumatic
connections from the pneumatics
assembly. You may want to mark the
positions of these connections to make
clear assignment easier later on.
Carefully remove the pneumatics unit.
Installation
Follow the removal instructions in reverse order for installation. Also observe the following
instructions:
Seal the compressed air system with sealant. Observe the instructions in section 5.4 "Seal-
ing the Pneumatic Screwed Connections" [}135] in connection with this.
5 Pneumatic System
5.8 Replacing the proportional controller (Location 4)
Service Manual SIPLACE X-Serie S 06/2019 139
5.8 Replacing the proportional controller (Location 4)
Parts, equipment and tools
Fig.171: Proportional controller [03152704‑xx] (version2)
Proportional controller Sentronic-LP
[03152704Sxx] (pressure control valve)
(replaces [03065425‑xx])
 NOTICE!
The proportional controller is supplied
with the latest parameters preset. Sub-
sequent programming is not possible.
.
Adapter plate, top [03136076‑xx]
Adapter plate bottom [03138952‑xx]
In vacuum mode, when only one proportional controller is fitted:
Sealing plate for prop. valve (with O-rings) [03113039-xx]
3x ISO4762-M4x55-A2–70 [03147182‑xx] (contained in [03152704Sxx])
(replaces 3x ISO4762-M4x70-A2-70 [03082432-xx] for the old proportional controller
[03065425‑xx])
Isoflex Topas NCA 52, can 1kg [00328369‑xx]
or
Isoflex Topas NCA 52, tube 50 g [00330850‑xx]
Loctite 241 [02101037‑xx]
Assembly instruction for "SIPLACE X-Series S, SX4/DX4 – Vacuum Pump", if needed
[DEEN:00196845‑xx]
Overview
Fig.172: Overview proportional controller (version 1)
1. to 4.: Location 1 to 4
5.: Proportional controller top and bottom
 NOTICE!
Only one proportional controller is fit-
ted for vacuum pump mode (all
heads).
When converting to compressed air
mode (Twin and CPP), you need to fit
a second pressure control valve.
Read also the assembly instructions
"SIPLACE X-Series S, SX4/DX4 – Va-
cuum Pump" [DE+EN: 00196845‑xx].
.
5 Pneumatic System
5.8 Replacing the proportional controller (Location 4)
140 Service Manual SIPLACE X-Serie S 06/2019
Fig.173: Overview proportional controller (version1)
Version 1:
1. Sealing adapter plate proportional con-
troller [03083211‑xx]
2. Adapter plate proportional controller
3. Fastening screws for adapter plate
Torque: 2.5 – 3.0Nm
4. Proportional controller
5. Fastening screws for proportional con-
troller
Torque: 2.0 – 2.5Nm
Fig.174: Overview proportional controller (version2)
Version 2:
1. 1x O-ring ID10 X 1.0 - NBR70
[03031296‑xx]
1x O-ring ID20 X 1.0 - NBR70
[03146099‑xx]
1x O-ring ID25 X 1.0 - NBR70
[03146100‑xx]
2. Adapter plate bottom [03138952‑xx]
3. 5x ISO10642-M4x14-A2-70
[03091400‑xx]
Torque: 2.5Nm
Loctite 241
4. 1x Proportional controller Sentronic-LP
[03152704‑xx]
5. 3x ISO4762-M4x55-A2-70
[03147182‑xx]
Torque: 2.0 – 2.5Nm
Loctite 241