6 Gantries 6.3 X and Y axis Service Manual SIPLACE X-Serie S 06/2019 147 Removal ► Switch off the machine, disconnect it from the power supply and secure it to prevent unauthorized reactivation. 1.2 "Preparatory wor…

100%1 / 428
6 Gantries
6.3 X and Y axis
146 Service Manual SIPLACE X-Serie S 06/2019
6.3 X and Y axis
6.3.1 Replacing the X axis incremental encoder
Parts, equipment and tools
Select the correct incremental encoder:
Machine Incremental encoder (read head)
SIPLACE X4i S, X4 S, X3 S, X2 S MS22/25 X axis [03094995‑xx]
SIPLACE X4i S micron, X4 S micron MS30 X axis [03102066‑xx]
For MS22/25 incremental encoder: test device PG1-I [03102699‑xx]
For MS20/30/35 incremental encoder: test device PG-U [03071361‑xx] from FS02 (see also
technical information "Checking the track signals at the X and Y axes" [DE:TI2019‑02D04]
[EN:TI2019‑02E04])
Sealing varnish Loctite 241 [02101037-xx]
Ethanol
Isopropanol – IPA can be used as an alternative.
Stepladder, if required
Overview
Fig.180: Overview
1. Vision board
2. Placement head on gantry
3. Head interface
4. Cable from temperature sensor and in-
cremental encoder X axis to head inter-
face
5. The X axis incremental encoder
6. Temperature sensor
6 Gantries
6.3 X and Y axis
Service Manual SIPLACE X-Serie S 06/2019 147
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation.
1.2 "Preparatory work..." [}16]
NOTICE
Recommendation
We recommend that you always perform the following tasks from the opposite side,
over the other gantry. You may need to use a stepladder or something similar to help
you.
Fig.181: Removing the incremental encoder
1. Head plate - front view
2. Incremental encoder
3. Three fastening screws
4. Grub screw (secured with Loctite 241)
Unplug the incremental encoder cable from the head interface. In this case make a note of the
position to make clear assignment easier later on.
Unthread the connection cable as far as the incremental encoder (2).
Remove the three screws (3) fastening the incremental encoder (2) of the X axis and carefully
remove the incremental encoder.
Installation
Fig.182: Fitting the incremental encoder
Clean the reading surface of the incre-
mental encoder with a cloth and eth-
anol or with a cleansing tip.
Loosely fasten the incremental encoder
(2) with three fastening screws (3).
The incremental encoder must be
aligned with a gap of 0.4mm (golden
scale) or 0.75mm (black-white scale)
to the scale. Use the corresponding
thickness gauge (plastic).
6 Gantries
6.3 X and Y axis
148 Service Manual SIPLACE X-Serie S 06/2019
Fig.183: Casting marks on the incremental encoder
Align the incremental encoder. Pay at-
tention to the following points:
Set the exact height of the scale.
Align the incremental encoder, us-
ing the two casting marks (arrows),
which mark the read area.
Align the incremental encoder paral-
lel to the scale. The gap at the top
and bottom must be the same size.
Tighten the fastening screws.
Reconnect to the electricity supply (connector X14 or X15 on head interface).
CAUTION
Check how the cables are run!
Make sure that the axes can be moved without damaging the cables.
Fasten the cables with cable ties.
Move the gantry into the end stopper and check that the buffer does not come into contact
with the cable.
Check the track signals with the test device (see 6.3.8 "Track Signals and Zero
Pulse" [}153]).
6.3.2 Replacing the Y axis incremental encoder
Parts, equipment and tools
Select the correct incremental encoder:
Machine Incremental encoder (read head)
SIPLACE X4i S, X4 S, X3 S, X2 S MS22/25 Y axis [03094996‑xx] (including plastic
thickness gauge)
SIPLACE X4i S micron, X4 S micron MS30 Y axis [03102065‑xx]
If needed, mounting bracket for Y axis sensor [03086842-xx]
For MS22/25 incremental encoder: test device PG1-I [03102699‑xx]
For MS20/30/35 incremental encoder: test device PG-U [03071361‑xx] from FS02 (see also
technical information "Checking the track signals at the X and Y axes" [DE:TI2019‑02D04]
[EN:TI2019‑02E04])
Ethanol
Isopropanol – IPA can be used as an alternative.