00197042-04_SM_X-Serie-S_Customer_EN - 第210页
7 Conveyor 7.2 Loosening the Conveyor Side Clamps 210 Service Manual SIPLACE X-Serie S 06/2019 7.2.2 Moving the Conveyor Sides by Manually Releasing the Side Clamps Parts, equipment and tools ● Per side: 3x ISO4762-M3x16…

7 Conveyor
7.2 Loosening the Conveyor Side Clamps
Service Manual SIPLACE X-Serie S 06/2019 209
7.2.1 Manually Moving the Conveyor Sides with the Help of the Adjustment Units
Docking in the adjustment units
If you are unable to move the sides with the software (e.g. due to a sensor error), proceed as follows:
► Switch off the machine.
► Switch off the BoxPC.
► Dismantle the lifting table plate at location 3.
► Switch the machine on (without BoxPC). The machine is now supplied with compressed air.
Fig.267: Width adjustment belt (example of SIPLACE X4S
with dual conveyor shown)
► Carefully pull on the width adjustment
belt to move the adjustment units until
they are under the clamps and the short-
stroke cylinder can activate the clamps.
Fig.268: Solenoid valves (example of SIPLACE SX1 shown)
► Operate the solenoid valves (individually
if needed) using the yellow slide
switches(1). This moves the cylinders
out, which then loosen the clamps.
Fig.269: Cylinder engaged
► Make sure that all side cylinders(1)
have engaged.
NOTICE!
The adjustment units need to be posi-
tioned under the conveyor side so that
all engage at the same time. If this is
not possible, check the parallelism of
the adjustment units. If these are OK,
the conveyor side may be distorted. In
this case, call the SIPLACE Service
team.
.
► Carefully pull on the width adjustment belt to move the conveyor side.
► Repeat these steps if needed for any other conveyor sides.

7 Conveyor
7.2 Loosening the Conveyor Side Clamps
210 Service Manual SIPLACE X-Serie S 06/2019
7.2.2 Moving the Conveyor Sides by Manually Releasing the Side Clamps
Parts, equipment and tools
●
Per side:
3x ISO4762-M3x16-A2-70 [03042545-xx]
Procedure
► Move the conveyor sides to a position which gives you good access to the clamps.
► Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation.
1.2 "Preparatory work..." [}16]
NOTICE
Marking the starting positions
After completing this task, it is helpful to move the conveyor sides back to their approximate
starting positions.
► You may want to mark the current positions of the conveyor sides.
Do not mark the clamping surface or the guide rails.
CAUTION
Loosen all clamps
You always need to loosen all clamps for one conveyor side.
Version 1
► Loosen the conveyor side clamps.
To do this, press the clamp(1) (e.g.
with a screwdriver) upwards and turn or
insert a screw (M3x16) into the
hole(2).
CAUTION!
Make sure that you do not distort the
guide plate(3). If you do, this could
lead to problems with recognizing the
position of the conveyor side.
.
Version 2
► Loosen the clamps on the conveyor
sides.
To do this, remove the disks above the
clamp compression springs (2 screws
for each disk). To do this, undo both
screws (1) on the clamps (2x for each
conveyor side).
CAUTION!
Compression springs
The compression springs are ten-
sioned. Make sure that you do not lose
these.
.

7 Conveyor
7.2 Loosening the Conveyor Side Clamps
Service Manual SIPLACE X-Serie S 06/2019 211
Version 3
► Loosen the conveyor side clamps.
To do this, press the lever(1) upwards
and push a suitable pin or a screw into
the hole(2).
► Repeat these steps for all clamps on the sides concerned.
CAUTION
Always loosen all clamps for one conveyor side!
► Always loosen all clamps for one conveyor side.
SIPLACE SX1/SX2/DX1/DX2: 2 clamps per conveyor side
SIPLACE SX4/DX4, X-Series S: 3 clamps per conveyor side
► If you do not loosen all clamps for the conveyor side, this could be easily damaged.
You can now move the sides.
CAUTION
Moving the sides
► When the clamp is manually loosened, make sure that you only move the conveyor
sides by pushing against the clamping units.
► Make sure that you always move the conveyor sides parallel.
► Take care not to distort or trap the conveyor sides when pushing!
Restoring the clamp
► Follow the removal instructions in reverse order for installation. Also observe the following
instructions:
●
After completing the work, push the conveyor sides back into their approximate starting posi-
tion.
●
Make sure that the conveyor sides are back in their original positions after switching on.
●
Perform a reference run.
●
Perform side calibration for the fixed side on the left and right. If you do not, not all conveyor
sides will be calibrated.
This calibration is needed to ensure that the conveyor sides are positioned correctly.
●
SIPLACE SX1/SX2 V2 and X-Series S only: calibrate the board sensors.
●
Use a board to test the parallelism. This board must be transported evenly through the entire
conveyor.
7.10.2 "Setting the Parallelism of the Conveyor Sides and Adjustment Units" [}298]
●
Re-establish the original conveyor configurations:
For more information, go to Service menu - Conveyor configuration - Set options for con-
veyor fixed rail.
Select one of the positions and click on the Adjust configuration button.
Then reset the conveyor sides to the previous configuration.