7 Conveyor 7.5 Width Adjustment, Clamps and Cylinder Unit Service Manual SIPLACE X-Serie S 06/2019 233 7.5.5 Replacing the proximity switch for the cylinder unit (width adjustment) Parts, equipment and tools ● New: proxi…

100%1 / 428
7 Conveyor
7.5 Width Adjustment, Clamps and Cylinder Unit
232 Service Manual SIPLACE X-Serie S 06/2019
Installation
Follow the removal instructions in reverse order for installation. Also observe the following
instructions:
Make sure that the cable is run correctly and does not rub against any parts.
Make sure that the cylinder unit lies flush against the trolley when you screw it into place.
(See also the following diagram)
Replace any open cable ties.
Make sure that the cable ties and the heads of the cable ties do not rub against any parts
when you do this.
After installation, make sure that the cylinder piston does not protrude above the other
parts. You might need to place washers between the adapter plate and the cylinder.
After installation, check whether the cylinder unit can be moved along the entire width of
the conveyor. Make sure that there are no interfering edges etc.
Check the distance to the clamping units. (see 7.5.9 "Information About the Clamping Unit
Versions (DC Only)" [}237]).
Fig.295: Fitting the cylinder unit
1. Trolley
2. Cylinder unit
3. The cylinder unit must lie flush against
the carriage. Make sure that there is no
gap in-between.
Recalibrate all conveyor sides for lane1 and2 (both in Dual conveyor right mode and in
Dual conveyor left mode).
7 Conveyor
7.5 Width Adjustment, Clamps and Cylinder Unit
Service Manual SIPLACE X-Serie S 06/2019 233
7.5.5 Replacing the proximity switch for the cylinder unit (width adjustment)
Parts, equipment and tools
New: proximity switch SME-8M-DS-24V-K-2.5 [03100139-xx]
or
Old: proximity switch SME-8-K-LED-24 [00343651-xx]
Overview
Fig.296: Sensor system (example of SX1/SX2 shown)
1. Proximity switch for the cylinder
2. Grub screw for fastening the sensor
3. Inductive sensor (position detection for
conveyor side)
Removal
Remove the cylinder unit. Please read section 7.5.4 "Replacing the Cylinder Unit (Width Ad-
justment)" [}230].
Remove the screw fastening the proximity switch.
Loosen the screw fastening the sensor.
Open the trailing cable and remove the sensor cable.
Installation
Follow the removal instructions in reverse order for installation. Also observe the following
instructions:
Dismantle the connector from the old proximity switch and fit it in the new proximity switch.
To do this, release the crimp connections on the old proximity switch from the connector
and insert them into the new proximity switch. Note the correct assignment for this!
Fix the new proximity switch to the correct position (see below).
The sensor must lie flush against the surface of the cylinder unit.
Fig.297: Setting the proximity switch
1. Distance between the lower edge of the
head plate and the upper edge of the
proximity switch:
13 mm for new proximity switch
SME-8M-DS-24V-K-2.5 [03100139-xx]
10 mm for old proximity switch SME-8-
K-LED-24 [00343651-xx]
7 Conveyor
7.5 Width Adjustment, Clamps and Cylinder Unit
234 Service Manual SIPLACE X-Serie S 06/2019
7.5.6 Replacing the inductive sensor for side detection on the cylinder unit (width
adjustment)
Overview
Fig.298: Proximity switch on the cylinder unit
1. Proximity switch on the cylinder unit
Proximity switch 3RG4/4.0mm/
sn=0.8mm/1S [00304908‑xx]
2. Screw fastening the proximity switch
3. Screw fastening the cylinder unit to the
carriage
Removal
Removal of the proximity switch is the same as that of the sensor system. Please read section
7.5.5 "Replacing the proximity switch for the cylinder unit (width adjustment)" [}233].
Loosen the screw fastening the proximity switch and pull the proximity switch out of the cylin-
der unit.
Installation
Follow the removal instructions in reverse order for installation. Also observe the following
instructions:
Dismantle the connector from the old inductive sensor and fit it in the new inductive sensor.
To do this, release the crimp connections on the old inductive sensor from the connector
and insert them into the new inductive sensor. Note the correct assignment for this!
Turn the proximity switch so that the LED is visible when fitted.
Make sure that the proximity switch does not protrude over the basic structure of the cylin-
der unit. Check this when the machine is switched on. To do this, move a conveyor side
over the cylinder unit. The LED should only shine when you do this. The gap between the
conveyor side clamping unit and the proximity switch on the cylinder unit must be at least
0.3 mm.
Check whether this gap is kept for all conveyor sides and that the proximity switch reliably
recognizes all conveyor sides. You can check this with the LED, when the machine is
switched on. Simply move the width adjustment manually along the conveyor with the help
of the toothed belt.
Recalibrate all conveyor sides for lane1 and2 (both in Dual conveyor right mode and in
Dual conveyor left mode).