00197042-04_SM_X-Serie-S_Customer_EN - 第31页

2 Basic Machine 2.4 Setting the Covers Service Manual SIPLACE X-Serie S 06/2019 31 2.4 Setting the Covers 2.4.1 Overview Fig.16: Overview of Settings 1. Setting the cover switch See 2.4.2 "Setting the Cover Switch&…

100%1 / 428
2 Basic Machine
2.3 Guide Rollers on the Covers
30 Service Manual SIPLACE X-Serie S 06/2019
Procedure
To make the work easier, proceed as follows:
Dismantle the bottom stop.
Loosen the screwed fixture on the roller (fork wrench size10). Unscrew as far as required.
Fig.15: Threaded pin
From the inside, screw on a threaded pin as lock and tighten it.
Checks
NOTICE
Covering
Between the roller and the guidance there must be at least 75% coverage along the entire
length of the guide rails.
Check whether the cover can be easily moved along the whole area. Adjust the cover if ne-
cessary (see 2.4 "Setting the Covers" [}31]).
2 Basic Machine
2.4 Setting the Covers
Service Manual SIPLACE X-Serie S 06/2019 31
2.4 Setting the Covers
2.4.1 Overview
Fig.16: Overview of Settings
1. Setting the cover switch
See 2.4.2 "Setting the Cover
Switch" [}31]
2. Setting the cover switch centering
See 2.4.3 "Setting the Cover Switch
Centering Device" [}32]
3. Setting the actuator
See 2.4.4 "Setting the Actuator" [}32]
4. Setting the bottom stop
See 2.4.5 "Setting the Bottom
Stop" [}33]
5. Setting the rollers
See 2.4.6 "Setting the Cover
Rollers" [}34]
2.4.2 Setting the Cover Switch
Fig.17: Cover switch (example of SIPLACE SX2 shown)
Cover switch [03055262-xx]
Loosen the screws fastening the cover
switch, the centering device and the ac-
tuator, so that the assemblies can be
easily moved.
CAUTION
Screws on actuator
With enforcement of the Machinery Directive DIN EN 1088 (2009), the following has been
executed to avoid misuse (e.g. putting the safety features out of action): the actuator and
machine protective switch screws have been replaced by Torx screws with pins. The relev-
ant set of tools may only be used for performing repair work.
Fig.18: Cover switch (example of SIPLACE SX2 shown)
Close the cover far enough for the actu-
ator to be just over the switch. Align
them so that the metal bracket is parallel
to the opening in the switch. The metal
bracket may not scrape against the
cover switch.
Tighten the cover switch screws in this
position.
2 Basic Machine
2.4 Setting the Covers
32 Service Manual SIPLACE X-Serie S 06/2019
2.4.3 Setting the Cover Switch Centering Device
Fig.19: Cover switch (example of SIPLACE SX2 shown)
Close the cover a little more until the
plastic centering device for the actuator
is against the cover switch centering
device. These two must be centered to-
wards one another.
Tighten the screws for the cover switch
centering device.
2.4.4 Setting the Actuator
Fig.20: Setting (example of SIPLACE SX2 shown)
Actuating bracket B1-2053 for AZ15/16
[00321649‑xx]
Close the cover completely.
Set the actuator so that it stands ap-
prox. 2 mm above the machine center
and tighten the screws.
 CAUTION!
The cover switch is not suitable as a
stop.
The cover switch is not a stop or a
support for the cover. Use the bottom
stops of the rollers for this (see next
section).
Neither the cover nor the actuator may
be supported on the cover switch.
There must be a visible gap between
the actuator and the cover switch.
.