8 Head exchange 8.5 Replacing the SIPLACE C&P20P/M2 Service Manual SIPLACE X-Serie S 06/2019 313 8.5 Replacing the SIPLACE C&P20P/M2 NOTICE Vacuum test ► If required, perform a vacuum test before removing the p…

100%1 / 428
8 Head exchange
8.4 SIPLACE C&P20 P on SIPLACE X-Series S machines
312 Service Manual SIPLACE X-Serie S 06/2019
Installation
Follow the removal instructions in reverse order for installation. Also observe the following
instructions:
If you replace the head without component camera, you will need to fit the old camera into
the new head. Read the service manual for your placement head for more information.
In vacuum pump mode, you need to dismantle the silencer from the old head and fit it to
the new one. Refer to the appropriate vacuum pump assembly instructions for details.
Make sure that the assembly position on the head plate is correct.
Tighten the four head fastening screws (M4, TX20) with a torque of 2.7 Nm.
NOTICE
Various hose lengths on SIPLACE X-Series S
The hose to the pressure control valve will vary in length, depending on the installation loc-
ation (standard gantry or rotated gantry).
Shorten or replace the hose, where necessary.
1.2 "Preparatory work..." [}16]
5.2 "Disabling the compressed air supply" [}134]
See also
2 8.8 "Installation Positions on the Head Plate" [}323]
8.4 SIPLACE C&P20 P on SIPLACE X-Series S machines
NOTICE
Vacuum pump/compressed air mode on SIPLACE X-Series S machines
Compressed air mode: if the SIPLACE C&P20 P is operated without a vacuum
pump, you must convert the head to compressed air mode. You will need the "Conver-
sion kit for compressed air mode SIPLACE C&P20P" [03106765‑xx].
Vacuum pump mode (default): If the SIPLACE C&P20 P is operated with a vacuum
pump, you will need the "Upgrade kit pressure sensor vacuum C&P20P for SIPLACE
X‑SeriesS" [03108457‑xx].
8 Head exchange
8.5 Replacing the SIPLACE C&P20P/M2
Service Manual SIPLACE X-Serie S 06/2019 313
8.5 Replacing the SIPLACE C&P20P/M2
NOTICE
Vacuum test
If required, perform a vacuum test before removing the placement head.
Read the "Service manual Vacuum test at C&P placement head" [DE+EN:
00196101‑xx] for this.
NOTICE
Prerequisites for the SIPLACE C&P20P
The following additional conditions must be fulfilled for operating a SIPLACE C&P20P:
Head interface - at least function state [03091013-03] / [03091023-03]
Base adapter - minimum function state [03055516-06] / [03045647-08]
MHCU – at least function state [03090990-03]
Nozzle changers [03103649-xx] must be used.
Nozzle station - at least function state [03073328-02]
NOTICE
Fast Hardware Exchange (FHE)
Observe the instructions in section 8.1 "Fast Hardware Exchange" [}305] when ex-
changing a head.
Parts, equipment and tools
SIPLACE C&P20P [03091157‑xx] (without camera)
SIPLACE C&P20M2 [03125907Sxx] (without camera)
NOTICE
Vacuum pump/compressed air operation
As a spare part, the head is prepared for vacuum pump operation.
Convert the placement head for compressed air operation using the "Hold-circuit com-
plete/C&P20" [03005123Sxx] kit.
Torx screwdriver ESD 1.0-5.0 Nm [03078400-xx]
Bit holder for TorqueVario screwdriver [03078706-xx]
Extension/straight TX20 [03073256-xx]
Torx offset screwdriver TX8 [03080081-xx]
Fig.397: Component sensor protective cap [03092400‑xx]
Component sensor protective cap
[03092400‑xx]
Calibration tool version SST23 [03034148-xx]
For additional work to the placement head:
Head mount [03056231‑xx]
Service manual "SIPLACE C&P20P head" [DE:00197489‑xx] [EN:00197490‑xx]
Job Card "Preventive Maintenance C&P20P" [DE:00197529‑xx] [EN:00197528‑xx] (other
languages available)
If required, for vacuum pump operation: Assembly instructions "Vacuum pump SIPLACE X-
Series S, SX4/DX4" [00196845-xx]
8 Head exchange
8.5 Replacing the SIPLACE C&P20P/M2
314 Service Manual SIPLACE X-Serie S 06/2019
Overview
Fig.398: SIPLACE C&P20P
1. Holding circuit connection
2. Intermediate distributor board (behind
the cover)
3. Component sensor
Fig.399: Fastening screws
1. Four fastening screws (yellow marks)
 NOTICE!
The length of the exhaust air hose "Sil-
icon hose Di8 Da12 electrically con-
ductive 1m" [03006727Sxx] on the
SIPLACE C&P20P/M2 is 355mm.
.
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation.
1.2 "Preparatory work..." [}16]
Switch off the compressed air supply
5.2 "Disabling the compressed air supply" [}134]
CAUTION
Take great care when dismantling the placement head!
The component sensor prisms, underneath the placement head, could be damaged.
Never place the placement head down on the component sensor.
Fit the protective cap onto the component sensor for the placement head.