00197042-04_SM_X-Serie-S_Customer_EN - 第349页
9 Component feeding 9.1 Cutter Service Manual SIPLACE X-Serie S 06/2019 349 Removal ► Switch off the machine, disconnect it from the power supply and secure it to prevent unauthorized reactivation. 1.2 "Preparatory …

9 Component feeding
9.1 Cutter
348 Service Manual SIPLACE X-Serie S 06/2019
9.1.11 Replacing Wiper Clip
Parts
Fig.461: Wiper left and right
03000506‑xx Wiper clip left (SIPLACE HF)
03000505‑xx Wiper clip, right (cutter HF)
Equipment and tools
00353832-xx Allen key set
Wire cutters
Cable ties
Overview
Fig.462: Wiper clips on cutter
1. Wiper clips

9 Component feeding
9.1 Cutter
Service Manual SIPLACE X-Serie S 06/2019 349
Removal
► Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation.
1.2 "Preparatory work..." [}16]
► Remove the cutter from the machine.
9.1.3 "Replacing the Cutter on the COT Insert [03066690-xx]" [}329]
► Remove the wiper.
9.1.10 "Replacing the wiper" [}346]
Fig.463: Removing the wiper clips
► Remove the two screws(1) (left and
right) and remove the wiper clips(2).
Installation
Fig.464: Installing the wiper clips
► Install the new wiper clips(2) on both
sides and loosely put the screws(1)
back in.
► Align the wiper clips to the edges of the
cutter frame(3) and to the cutter top
blade(4).
► Tighten the screws(1) fixing the wiper
clips.
► Follow the removal instructions in reverse order for further installation.

9 Component feeding
9.1 Cutter
350 Service Manual SIPLACE X-Serie S 06/2019
9.1.12 Replacing the cutter cable
Parts
03063590-xx Cutter cable X-Series
Equipment and tools
00353832-xx Allen key set
Wire cutters
Cable ties
Overview
Fig.465: Electrical connections
Removal
► Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation.
1.2 "Preparatory work..." [}16]
► Switch off the compressed air supply
5.2 "Disabling the compressed air supply" [}134]
Fig.466: Cutter cable
► Disconnect all sensors and plugs and
remove the cable set completely.
Mark the position of old sensors, espe-
cially the sensors responsible for posi-
tioning the short-stroke cylinders.
Installation
► Fit the new cable set and adjust the sensors to the correct position.
► Follow the removal instructions in reverse order for further installation.
●
Attach cables ties if necessary (strain relief).