00197042-04_SM_X-Serie-S_Customer_EN - 第383页
9 Component feeding 9.4 Docking Station for Component Trolley Service Manual SIPLACE X-Serie S 06/2019 383 9.4.4 Replacing the locking unit short-stroke cylinder Parts Fig.515: Short-stroke cylinder 03034831-xx Short-st…

9 Component feeding
9.4 Docking Station for Component Trolley
382 Service Manual SIPLACE X-Serie S 06/2019
► Set the output voltage of the power pack to 26.8 V at terminals nine and twelve:
– Standard (without BulkFeeder):
26.8 V (+/- 0.5 V)
– When using the BulkFeeders the output voltage is set permanently to 28.0V(+/‑0.5V).
► Refit the cover.
9.4.3 Replacing the micro switch
Parts
03033387‑xx Microfuse
Overview
1
Fig.513: Microfuse on docking station
1. Position of microfuse (T 8.0 A)
Replacing the microfuse
1
3
2
Fig.514: Replacing the microfuse
1. Cover on the microfuse (T8.0A)
2. ON / OFF switch
3. Power supply plug
DANGER!
Switch off the voltage supply
Press the ON/OFF button (2) to switch
off and then unplug the power supply
(3).
.
► Open the cover (1) on the microfuse.
► Remove the microfuse.
► Insert the new microfuse and close the cover (1).
► Connect the connection cable (3) and press the ON/OFF button to switch on (2).

9 Component feeding
9.4 Docking Station for Component Trolley
Service Manual SIPLACE X-Serie S 06/2019 383
9.4.4 Replacing the locking unit short-stroke cylinder
Parts
Fig.515: Short-stroke cylinder
03034831-xx Short-stroke cylinder
Equipment and tools
00353832-xx Allen key set
Lint-free cloth
Unisilikon
Overview
Fig.516: Locking unit left and right
1. Installation position of left locking unit
2. Installation position of right locking unit

9 Component feeding
9.4 Docking Station for Component Trolley
384 Service Manual SIPLACE X-Serie S 06/2019
Removal
5
1
4
3
2
Fig.517: Removing the locking unit
CAUTION!
Risk of injury
Risk of injury when disconnecting
pressurized compressed air lines.
.
► Switch off the compressed air supply.
► Remove the pneumatic connections on
the short-stroke cylinder.
► Remove the two screws (1) fastening
the short-stroke cylinder (2).
► Pull the short-stroke cylinder and the
locking slider(3) downwards and out of
the guidance block(5).
► Unscrew the locking slider from the
short-stroke cylinder(2).
Installation
► Fit the locking slider onto the new short-stroke cylinder.
► Clean the locking sliders and the guidance block with a clean, lint-free cloth and lubricate both
slightly with Unisilikon.
► Move the locking slider into the guidance block, so that the beveled side (4) is pointing to the
front (in the direction of travel). This is important when moving the component trolley in.
► Fit the short-stroke cylinder with the two fastening screws.
► Reconnect to the compressed air supply.
► Switch the compressed air supply on and check that the left and right locking sliders move out
at the same time.
► If necessary, adjust the throttle valve on the short-stroke cylinder.
9.4.5 Replacing the locking lever
Parts
Fig.518: Horizontal tensioner
03025104-xx Horizontal tensioner DE-STA-CO 225-U
Equipment and tools
00353832-xx Allen key set