10 Vacuum Pump 10.5 Replacing the suppressor module in the connector unit box 424 Service Manual SIPLACE X-Serie S 06/2019 10.5 Replacing the suppressor module in the connector unit box Parts, equipment and tools ● EMC s…

100%1 / 428
10 Vacuum Pump
10.4 Replacing the power supply cable for the vacuum pump
Service Manual SIPLACE X-Serie S 06/2019 423
10.4 Replacing the power supply cable for the vacuum pump
Parts, equipment and tools
Cable: power supply for vacuum pump [03079997-xx]
You will also need the relevant assembly instruction manual for your machine:
Assembly instructions "Option Vacuum Pump SIPLACE X-Series S up to Gxxxx, SX4/
DX4" [DE+EN:00196845‑xx]
Assembly instructions "Option Vacuum Pump SIPLACE X-Series S from Hxxxx " [DEEN:
00198599‑xx]
Overview
Fig.580: Connector unit box
The power supply cable for the vacuum
pump leads from the connector unit box to
the vacuum pump.
The connector unit box is located at the bot-
tom of the machine frame, at location 2.
Connection on the connector unit box
Terminal Description
X2qr Voltage
X3qr Control
X4qr, X5qr Pumps (sequence not important)
If only one pump is installed, the second connection must be closed with a bridge
connector.
X6qr Fan
Fig.581: Cable connections on the vacuum pump
1. Conductor (1) to connection V1
2. Conductor (2) to connection U1
3. Conductor (3) to connection W1
4. Protective ground at connection (4)
5. Black cable (temperature monitor) on
the luster terminal(5)
Removal/installation
Refer to the appropriate assembly instructions.
10 Vacuum Pump
10.5 Replacing the suppressor module in the connector unit box
424 Service Manual SIPLACE X-Serie S 06/2019
10.5 Replacing the suppressor module in the connector unit
box
Parts, equipment and tools
EMC suppressor module RC 3x400V 575VAC 4kW [03097216-xx]
Overview
Fig.582: Suppression module
Suppression module
Fig.583: Connector unit box
1. Installation point of suppression module
2. The suppression module is connected
to terminal 2, 4 and 6.
Removal
The suppressor module is fitted in the connector unit box. The connector unit box is located at the
bottom of the machine frame, at location 2.
For more information, read section 10.3 "Replacing the connector unit box" [}422].
Installation
Observe the following instructions during installation:
Cut off the cable lugs and remove approx. 1 cm of insulation from the end of the cable.
Unlock the terminals (e.g. with a screwdriver) and insert one cable each into terminals 2, 4
and6.
10 Vacuum Pump
10.6 Replacing the circuit breaker in the connector box
Service Manual SIPLACE X-Serie S 06/2019 425
10.6 Replacing the circuit breaker in the connector box
Parts, equipment and tools
Circuit breaker 5SY6 3pol 6A C [03079445-xx]
Removal/Installation
The circuit breaker is located in the connector unit box. The connector unit box is located at the
bottom of the machine frame, at location 2.
For more information, read section 10.3 "Replacing the connector unit box" [}422].
10.7 Replacing the button in the connector unit box
Parts, equipment and tools
Button 5TE4 800 [03072025-xx]
Removal/Installation
The button is located in the connector unit box. The connector unit box is located at the bottom of
the machine frame, at location 2.
For more information, read section 10.3 "Replacing the connector unit box" [}422].
10.8 Replacing the relay terminal block in the connector unit
box
Parts, equipment and tools
Relay terminal block DEK-REL-G24/21 24VDC 1 Wech [03086538-xx]
Removal/Installation
The relay terminal block is located in the connector unit box. The connector unit box is located at
the bottom of the machine frame, at location 2.
For more information, read section 10.3 "Replacing the connector unit box" [}422].
10.9 Replacing the diode terminal block in the connector unit
box
Parts, equipment and tools
Diode terminal block 2.5qmm gray 4L with 1N4007 [03006763-xx]
Removal/Installation
The diode terminal block is located in the connector unit box. The connector unit box is located at
the bottom of the machine frame, at location 2.
For more information, read section 10.3 "Replacing the connector unit box" [}422].