3 Power supply 3.4 Power supply and transformer module (up to serial number Gxxx) Service Manual SIPLACE X-Serie S 06/2019 53 3.4.2 Overview of Distributor and I/O Module Fig.50: Distributor 03052315-02 (without SMPS) F…

100%1 / 428
3 Power supply
3.4 Power supply and transformer module (up to serial number Gxxx)
52 Service Manual SIPLACE X-Serie S 06/2019
3.4 Power supply and transformer module (up to serial
number Gxxx)
DANGER
Checking for absence of voltage!
Before you start working, check the power supply for absence of voltage and observe
the waiting times!
3.4.1 Overview
The power supply unit is mounted on a compact rack unit and is located between location 3 and 4.
A lockable door prevents access to the power supply.
Fig.48: Power supply (US version)
Power supply [00354626-xx]
1. Motor protection switch with motor pro-
tection trip block
2. LEDs, microfuses (SP distributor assembly
board (A10), under the mesh cover)
3. Output coupling link
4. Two boards are fitted above one another
here.
Inrush current limiter board for servo
Inrush current limiter board for transformer
5. Line filter, load add circuit, ballast resistor
(under the mesh cover)
6. Protective contactor combination
7. AC/DC converter A5 to A8
Fig.49: Overview fuses
3 Power supply
3.4 Power supply and transformer module (up to serial number Gxxx)
Service Manual SIPLACE X-Serie S 06/2019 53
3.4.2 Overview of Distributor and I/O Module
Fig.50: Distributor 03052315-02 (without SMPS)
Fig.51: Overview of distributor
3 Power supply
3.4 Power supply and transformer module (up to serial number Gxxx)
54 Service Manual SIPLACE X-Serie S 06/2019
Fig.52: Overview of distributor