00197042-04_SM_X-Serie-S_Customer_EN - 第65页

3 Power supply 3.4 Power supply and transformer module (up to serial number Gxxx) Service Manual SIPLACE X-Serie S 06/2019 65 3.4.12 Replacing the protective contactor combination Parts, equipment and tools Fig.65: Prot…

100%1 / 428
3 Power supply
3.4 Power supply and transformer module (up to serial number Gxxx)
64 Service Manual SIPLACE X-Serie S 06/2019
3.4.11 Replacing the line filter (Z1)
Parts, equipment and tools
Line filter for 3-phase systems 36A (Z1) [03078386-xx]
Overview
Fig.64: Overview of line filter and load add circuit
1. Cover
2. Line filter (Z1)
3. Load add circuit (A4)
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation.
1.2 "Preparatory work..." [}16]
Before you start working, check the power supply for absence of voltage and observe the
waiting times!
Remove the screws fastening the cover and swing the cover towards the front. The AC/DC
converters are also fitted on the cover. These are swung away with the cover.
Unplug all connections to the line filter. You might like to mark their positions to make clear
assignment easier later on.
Remove the three screws fastening the line filter and then take the line filter off.
Installation
Follow the removal instructions in reverse order for installation.
3 Power supply
3.4 Power supply and transformer module (up to serial number Gxxx)
Service Manual SIPLACE X-Serie S 06/2019 65
3.4.12 Replacing the protective contactor combination
Parts, equipment and tools
Fig.65: Protective contactor combination
1. Protective contactor combination
3TK28 25 [00358268-xx]
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation.
1.2 "Preparatory work..." [}16]
Before you start working, check the power supply for absence of voltage and observe the
waiting times!
Unplug all connections to the protective contactor combination. You might like to mark their
positions to make clear assignment easier later on.
Take the protective contactor combination off the rail. To do this, press the protective con-
tactor combination upwards slightly and tilt it.
Installation
Follow the removal instructions in reverse order for installation.
3 Power supply
3.4 Power supply and transformer module (up to serial number Gxxx)
66 Service Manual SIPLACE X-Serie S 06/2019
3.4.13 Replacing the output coupling link (K7)
Parts, equipment and tools
Fig.66: Output coupling link
1. Output coupling link 24V AC/DC 1W
[03065954-xx]
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation.
1.2 "Preparatory work..." [}16]
Before you start working, check the power supply for absence of voltage and observe the
waiting times!
Unplug all connections to the output coupling link. You might like to mark their positions to
make clear assignment easier later on.
Take the output coupling link off the rail.
Installation
Follow the removal instructions in reverse order for installation.