00197042-04_SM_X-Serie-S_Customer_EN - 第66页
3 Power supply 3.4 Power supply and transformer module (up to serial number Gxxx) 66 Service Manual SIPLACE X-Serie S 06/2019 3.4.13 Replacing the output coupling link (K7) Parts, equipment and tools Fig.66: Output coup…

3 Power supply
3.4 Power supply and transformer module (up to serial number Gxxx)
Service Manual SIPLACE X-Serie S 06/2019 65
3.4.12 Replacing the protective contactor combination
Parts, equipment and tools
Fig.65: Protective contactor combination
1. Protective contactor combination
3TK28 25 [00358268-xx]
Removal
► Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation.
1.2 "Preparatory work..." [}16]
► Before you start working, check the power supply for absence of voltage and observe the
waiting times!
► Unplug all connections to the protective contactor combination. You might like to mark their
positions to make clear assignment easier later on.
► Take the protective contactor combination off the rail. To do this, press the protective con-
tactor combination upwards slightly and tilt it.
Installation
► Follow the removal instructions in reverse order for installation.

3 Power supply
3.4 Power supply and transformer module (up to serial number Gxxx)
66 Service Manual SIPLACE X-Serie S 06/2019
3.4.13 Replacing the output coupling link (K7)
Parts, equipment and tools
Fig.66: Output coupling link
1. Output coupling link 24V AC/DC 1W
[03065954-xx]
Removal
► Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation.
1.2 "Preparatory work..." [}16]
► Before you start working, check the power supply for absence of voltage and observe the
waiting times!
► Unplug all connections to the output coupling link. You might like to mark their positions to
make clear assignment easier later on.
► Take the output coupling link off the rail.
Installation
► Follow the removal instructions in reverse order for installation.

3 Power supply
3.4 Power supply and transformer module (up to serial number Gxxx)
Service Manual SIPLACE X-Serie S 06/2019 67
3.4.14 Replacing the socket
Parts, equipment and tools
Fig.67: Socket
1. Socket, rail-mounted SD-D/SC/LA/GY
[00375320‑xx]
NOTICE!
The socket might be not be fitted in
some machine versions.
.
Removal
► Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation.
1.2 "Preparatory work..." [}16]
► Before you start working, check the power supply for absence of voltage and observe the
waiting times!
► Unplug all connections to the socket. You might like to mark their positions to make clear as-
signment easier later on.
► Take the socket off the rail.
Installation
► Follow the removal instructions in reverse order for installation.