00198368-01_UM_SIPLACESX12-DockingStation_DE_EN_ZH - 第47页

User manual Docking station for SIPLACE SX component trolleys 1 Introduction Edition 02/2018 1.2 Docking station serial number 47 1.2.1 EC Declaratio n of conformity The product descr ibed below: 1 1 Manufactured by ASM …

100%1 / 116
1 Introduction User manual Docking station for SIPLACE SX component trolleys
1.2 Docking station serial number Edition 02/2018
46
The main tasks performed by the docking station are as follows:
Supply of energy to the component trolley and X feeder modules
Provision of an infrastructure for communication between the pre-setup location PC and the
feeder modules
With the help of the docking station, the operator can perform function tests to the X feeder mod-
ules outside the production environment and can check the setup. There are two rows, each with
four docking stations, connected via the CAN bus of the pre-setup PC. Each docking station has
its own power and compressed air connection.
The COT insert for the docking station can be adjusted to the required PCB conveyor height. The
component trolley is pushed into the docking station for the pre-setup process. The component
trolley slides along the COT insert rails with the roller bearings on its sides, asm far as the energy
and data interface connection. The EDIF in the COT insert unit is positioned precisely in relation
to the changeover table with the feeder module EDIF.
1.2 Docking station serial number
The docking station serial number is located on the typeplate.
1
Fig. 1.2 - 1 Position of typeplate
(1) Typeplate
(1)
User manual Docking station for SIPLACE SX component trolleys 1 Introduction
Edition 02/2018 1.2 Docking station serial number
47
1.2.1 EC Declaration of conformity
The product described below:
1
1
Manufactured by
ASM Assembly Systems GmbH&Co.KG
Rupert-Mayer-Str. 44
81379 Munich 1
conforms to the regulations and standards listed in the EC Declaration of
Conformity provided.
1.2.2 Use as prescribed
The "use as prescribed" is defined as follows:
The docking station is to be used for external setup of component trolleys with feeder mod-
ules, function tests and setup verification checks.
The docking station may only be used in the situations prescribed in the catalogs and techni-
cal documentation, in accordance with the printed circuit board and component specifica-
tions. Use for a different or extended purpose is not prescribed.
The docking station may only be used in conjunction with the third party devices and compo-
nents recommended or approved by the manufacturer and only together with authorized
spare parts. Use for a different or extended purpose is not prescribed.
The docking station may only be used in accordance with the installation, connection and op-
erating conditions defined in this user manual.
The docking station may only be connected to the operating voltage if it has been properly
installed and this installation has been inspected.
The docking station may only be put into operation or operation continued if all required warn-
ing labels are present at the correct points on the machine and are clearly legible.
Product
Docking station
Type Docking station for SIPLACE SX component trolleys
Item no.: 00116965-xx
1 Introduction User manual Docking station for SIPLACE SX component trolleys
1.2 Docking station serial number Edition 02/2018
48
The fault-free and safe operation of the product requires proper storage, transportation, cor-
rect installation, assembly and initial start-up plus careful use, maintenance and service by
sufficiently qualified personnel, which have been authorized by the manufacturer to perform
the work concerned, after being trained as required.
The use as prescribed also includes the observance of all instructions in the installation man-
ual, user manual and, primarily, in the user manual for the relevant SIPLACE placement ma-
chines, as the docking station is connected to the placement machine via the signaling and
mechanical systems, thereby making it mandatory for personnel to know about the interaction
of these machines and to act accordingly.
In addition, observe the interface and signaling procedure instructions in the user manuals of
any other modules which are connected.
The contents of the above mentioned installation and user manuals for the docking station
and of the user manual for the SIPLACE placement machine and the user manuals of any
other modules/machines connected must be understood and observed in full so that the re-
quirements for initial start-up/switching on of the docking station and therefore for "use as pre-
scribed" are fulfilled.
In the event of non-prescribed use, the manufacturer will not accept liability for any damage or
injuries occurring and shall not provide warranty cover for fault-free and proper functioning of the
docking station.
The product may only be used for the areas of application specified in the catalogues and techni-
cal descriptions i.e. for the placement of SMD components and may only be used together with
the third party devices and components recommended or approved by ASM Assembly Systems
GmbH & Co. KG. Use for a different or extended purpose is not prescribed.
In the case of incorrect usage, ASM Assembly Systems GmbH & Co. KG will not assume liability
for any damage which occurs and will not guarantee the correct and proper function of machine
components.
Use as prescribed also includes compliance with all the instructions in the user manual.
For the product to operate correctly and reliably, it must have been transported, stored, erected
and assembled correctly and must be operated and maintained with care.