User Manual SIPLAC E CF 2 Operational safety Software Vers ion SR.408.xx 03/2006 US Ed ition 2.6 Residual voltages and discharge t imes in the ma chine 53 2.6 Residual v olt ages and discharge times in the machine When t…

2 Operational safety User Manual SIPLACE CF
2.5 Safety equipment Software Version SR.408.xx 03/2006 US Edition
52
2.5.5 Guard on the component table locations
WARNING 2
All locations must be equipped with feeders in order to guarantee operational reliability. If there
are not enough feeders available, a guard ("dummy feeder") must be fitted in place of the feeder.2
2
Fig. 2.5 - 6 Hand guard
2
(1) Hand guard for 1 location item no. 00116961-01
(2) Hand guard for 6 to 10 locations item no. 00116962-01
(3) Hand guard for 11 to 20 locations item no. 00116963-01

User Manual SIPLACE CF 2 Operational safety
Software Version SR.408.xx 03/2006 US Edition 2.6 Residual voltages and discharge times in the machine
53
2.6 Residual voltages and discharge times in the
machine
When the EMERGENCY STOP button is pressed or the placement system is switched off, the
electrolytic capacitors quickly discharge to safe residual voltage levels via switched resistors on
the discharge board (00308443-xx).
The voltages can be tapped off at test sockets 001 - 009 on the voltmeter unit in the servo unit.
WARNING 2
Automatic placement systems from the SIPLACE family are powered with 3 x 400 VAC (3 x 208
VAC for the U.S.A. version) ± 5 %, 50/60 Hz main power voltage. This means that some parts of
the system carry potentially lethal voltages - even when switched off at the main power switch.
Death, serious injury or considerable damage may result if these automatic placement systems
are handled incorrectly. Always follow the applicable accident prevention and DIN regulations
(particularly EN 60204, part 1).
The guard over the servo unit must ONLY be opened by appropriately qualified and trained per-
sonnel. 2
2
Fig. 2.6 - 1 Test sockets on the voltmeter unit in the servo unit
GND
007
001 002 003
004
005 006
008 009
100VDC/
0VDC
30VDC 24VDC 12VDC 5VDC
100VDC
155VDC/0VDC
30VDC
unswitched
switched

2 Operational safety User Manual SIPLACE CF
2.6 Residual voltages and discharge times in the machine Software Version SR.408.xx 03/2006 US Edition
54
2.6.1 Operating voltages, residual voltages and discharge times after pressing
the EMERGENCY STOP button
2
2.6.2 Residual voltages and discharge times after switching off at the main switch
2
CAUTION
To avoid losing data, evaluate the following criteria before switching off your automatic placement
system (apart from in emergencies):
– Has the placement system finished transmitting machine, setup and panel data?
– Has the placement system finished processing the PCB?
– Has the placement system completed the run-up phase?
– Has the Windows XP operating system been shut down correctly? 2
Test socket 00X
measured at 007
(GND)
Voltage in
normal mode
Residual voltage
after
EMERG. STOP
Discharge times of
electrolytic capacitors at
12 VDC
001 100 VDC 10 VDC < 2 sec
002 30 VDC 30 VDC –
003 30 VDC < 12 VDC < 2 sec
004 24 VDC 24 VDC –
005 12 VDC 12 VDC –
006 5 VDC 5 VDC –
008 100 VDC 10 VDC < 2 sec
009 155 VDC 10 VDC < 1 sec
Tab. 2.6 - 1 Operating voltages, residual voltages and discharge times after pressing the EMERGENCY STOP
button
Test socket 00X
measured at 007 (GND)
Residual voltage when
main power switch is off
Discharge times of electrolytic
capacitors at 12 VDC
001 < 12 VDC < 2 sec
002 < 12 VDC < 2 sec
003 < 12 VDC < 2 sec
004 0 VDC –
005 0 VDC –
006 0 VDC –
008 < 12 VDC < 2 sec
009 < 12 VDC < 1 sec
Tab. 2.6 - 2 Residual voltages and discharge times after switching off at the main switch