Pump mode key and LED Troubleshooting 6-7 Part 1126931_01  2018 Nordson Corporation 5. Press the Pump mode key to save the value and move to the next parameter. 6. Repeat steps 3-4 for each parameter you want to change.…

100%1 / 206
Control switch
Pump speed arrow keys
Troubleshooting
6-6
Part 1126931_01
2018 Nordson Corporation
Changing a Motor Control Parameter
The motor control parameters are factory set and do not need to be changed.
Use this procedure only if a motor control parameter is inadvertently changed
and needs to be changed back to the factory setting shown in Table 6‐3. The
motor control parameters are changed through the motor control panels
located on the front of the melter.
To change the a motor control parameter
1. Place the main power switch in the OFF position.
2. Place the control switch in the OFF position.
3. Press and hold both Pump speed arrow keys and then switch the
control switch back on. When the pump speed display indicates SEt,
release the keys.
4. Use the Pump speed arrow keys to select a value for the parameter
shown on the pump speed display. Refer to Table 6‐3 for a parameter list.
Pump mode key and LED
Troubleshooting
6-7
Part 1126931_01
2018 Nordson Corporation
5. Press the Pump mode key to save the value and move to the next
parameter.
6. Repeat steps 3-4 for each parameter you want to change.
7. To exit the setup mode, press the Pump mode key one additional time
after the last parameter has been displayed.
Table 6‐3 Motor Control Parameter Factory Settings
Parameter Factory Setting Description Explanation
SEt 94 Maximum pump rpm This parameter controls the increment of
change in motor speed that occurs upon
each press of a pump speed up or down
arrow key when the melter is operating in
the manual mode. To change the rpm in
increments of 1, set this parameter to the
maximum pump rpm.
Srt 0 Motor start mode This parameter controls the method used
to start the motor(s):
To start a motor by pressing the pump
start/stop key on a motor control panel,
enter 0. This setting is typically used if a
melter has more than one motor.
If you want a motor to start when the
pump enable signal is activated, enter 1.
This setting is typically used if a melter
has only one motor.
LoS 0 Minimum pump speed
in gear‐to‐line mode
If the melter will be operated in the
manual mode, enter 0.
If the melter will operated in the
gear‐to‐line mode, enter a minimum line
speed. The motor speed will not fall
below this valve even if the signal drops
to 0 V.
Troubleshooting
6-8
Part 1126931_01
2018 Nordson Corporation
Motor Drive Faults
The display on the motor drive located inside the electrical enclosure alerts
the operator to abnormal motor drive/motor operation. Motor drive faults
cause the pump to stop, refer to the motor drive Error Messages given later.
To clear a motor drive fault, correct the problem that caused the fault and
then remove power from the motor drive by turning the heaters off and wait
until the motor drive display is completely blank.
1
2
Figure 6‐1 Motor drive power LED and display
1. Motor drive Ready (RDY) LED 2. Motor drive Error (ERR) LED