Troubleshooting 6-17 Part 1126931_01 2018 Nordson Corporation Favorites Group Navigation Screen Type Display Parameters Keypad Button Selection Operating Screen VEL:FLEX:AIN1 ST OP REM AUTO SETS Press Groups Screen Fav…

Troubleshooting
6-16
Part 1126931_01
2018 Nordson Corporation
Display (contd)
Every parameter has a hexadecimal address. Parameters which are visible
on the keypad also have a display code. In the Easy Starter Display Code
and hexadecimal address are visible. Every parameter can have
sub-parameters.
Example Display code Address
V/f base frequency P302.02 0x2B01:002
Start control P200.00 0x2824:000
The parameters are organized into groups 0 through 7:
Group Name Group Name
0 Favorites menu 4 Function and I/O menu
1 Diagnostics 5 Network setup menu
2 Basic setup 6 Process control menu
3 Motor setup 7 Auxiliary function menu
The favorites menu contains links to the most commonly used parameters for
initial commissioning and monitoring of the motor drive for general
applications.

Troubleshooting
6-17
Part 1126931_01
2018 Nordson Corporation
Favorites Group Navigation
Screen Type Display Parameters Keypad Button Selection
Operating Screen
VEL:FLEX:AIN1
STOP
REM
AUTO SETS
Press
Groups Screen
Favorites
GROUP 0
REM
AUTO
SETS
Press
Parameter Screen
Actual Frequency
P100.00
REM
AUTO SETS
Press ten (10)
times
Parameter Screen
Max Frequency
P211.00
REM
AUTO SETS
Press
Setting Screen
P211/000 Hz
50.0
REM
AUTO SETS
Press until 87.0
is displayed
Setting Screen
P211/000 Hz
87.0
REM
AUTO SETS
Press
Parameter Screen
Max Frequency
P211.00
REM
AUTO SETS
Press
NOTE: Use the Up and Down buttons to
navigate to other parameters in Group 0.
In this example, the BACK button is used
to return to Group list.
Groups Screen
Favorites
GROUP 0
REM
AUTO
SETS
Press
NOTE: Use the Up and Down buttons to
navigate to other groups. In this example,
the BACK button is used to return to the
Operating Screen.
Continued...

AUTO
VEL:FLEX:AIN1
PSAVED
REM AUTO
VEL:FLEX:AIN1
Savingp
REM
Troubleshooting
6-18
Part 1126931_01
2018 Nordson Corporation
Favorites Group Navigation (contd)
Screen Type Display Parameters Keypad Button Selection
Operating Screen
VEL:FLEX:AIN1
STOP
REM AUTO SETS
We are at the Operating Screen.
Saving the Settings
After the adjustments are complete, press for three (3) seconds to save
all the settings to memory.
The
SET8
icon blinks when the settings are not saved. Once the
settings are saved, the icon is steady.