DuraBlue II Customer Product Manual - 第173页

Calculating Melter Power Requirements A-3 Part 1126931_01  2018 Nordson Corporation Table A ‐1 Hose/Applicator Wattages Component Number T ype/Size A B C Component Wattage Hose/Applicator Pair Wattage Two Hose/Applicato…

100%1 / 206
Calculating Melter Power Requirements
A-2
Part 1126931_01
2018 Nordson Corporation
Evaluate Hose/Applicator Power Requirements
1. Identify all hose/applicator pairs based on the hose/applicator receptacle
to which they are connected.
2. Examine the identification tag or plate on each hose and applicator and
record the wattage of each in Column A of Table A‐1. Enter a zero for any
hose or applicator that is not installed.
3. Add the wattages of each hose/applicator pair and place the sum in
Column B of Table A‐1.
4. Add the wattages of the hose/applicator pairs and place the sum in
Column C of Table A‐1.
5. Compare each of the wattages tabulated in Columns A, B, and C of Table
A‐1 with the associated maximum allowable wattages in TableA‐2, as
appropriate.
6. Do one of the following:
If each of the wattages calculated in step 5 do not exceed the
associated maximum allowable wattages listed in Table A‐2, then the
power required by the hoses and applicators is within acceptable
limits.
If any of the wattages calculated in step 5 does exceed an associated
maximum allowable wattage listed in Table A‐2, then the
configuration or position of the hose/applicator pairs must be
rearranged, shorter hoses must be used, or lower power applicators
must be used in order to reduce the power requirement.
Calculating Melter Power Requirements
A-3
Part 1126931_01
2018 Nordson Corporation
Table A‐1 Hose/Applicator Wattages
Component
Number
Type/Size
A B C
Component
Wattage
Hose/Applicator
Pair Wattage
Two
Hose/Applicator
Pair Wattage
Hose 1
Applicator 1
Hose 2
Applicator 2
Hose 3
Applicator 3
Hose 4
Applicator 4
Hose 5
Applicator 5
Hose 6
Applicator 6
Table A‐2 Maximum Allowable Hose/Applicator Wattages
Column in
Table A‐1
Component Maximum Wattage
A Any single hose or applicator 1000 W
B Any hose/applicator pair 1200 W
C
Sum of hose/applicator pairs 1
and 2
2000 W
Sum of hose/applicator pairs 3
and 4
2000 W
D
Any single hose, or applicator 5
or 6
2000 W
E Hose/applicator pair 5 or 6 2000 W
F
Sum of hose/applicator pairs 5
and 6
4000 W
NOTE: Total external wattage must not exceed 8,000 W.
Calculating Melter Power Requirements
A-4
Part 1126931_01
2018 Nordson Corporation