Operating Parameters B-15 Part 1126931_01 2018 Nordson Corporation 57 Schedule 1 Enter Standby Description: Used to set the time that the melter will enter the standby mode during schedule 1. Value: 0000 to 2359, ‐ ‐ ‐…

Operating Parameters
B-14
Part 1126931_01
2018 Nordson Corporation
50 Current Day
Description:
Used to set the current day of the week.
Value:
1 to 7 (1 = Monday, 2 = Tuesday, etc.)
Resolution:
1
Default Value:
—
Format:
—
Use:
Refer to Section 4, Operation, Function Keys, for information about the use and
affects of the seven‐day clock feature.
51 Current Time
Description:
Used to set the local time of the day.
Value:
0000 to 2359 (European time format)
Resolution:
1 minute
Default Value:
(Time set at factory)
Format:
Hours, Hour: Minute, Minute
Use:
This setting only needs to be made once for all daily schedules
55 Schedule 1 Heaters On
Description:
Used to set the time that the clock will turn on the heaters during schedule 1.
Value:
0000 to 2359, ‐ ‐ ‐ ‐
Resolution:
1 minute
Default Value:
0600
Format:
Hours, Hour: Minute, Minute
Use:
Set the desired time for the heaters to turn on.
To disable this parameter, set the parameter's value to “‐ ‐ ‐ ‐” by simultaneously
pressing both of the right‐display scroll keys.
56 Schedule 1 Heaters Off
Description:
Used to set the time that the clock will turn off the heaters during schedule 1.
Value:
0000 to 2359, ‐ ‐ ‐ ‐
Resolution:
1 minute
Default Value:
1700
Format:
Hours, Hour: Minute, Minute
Use:
To disable this parameter, set the parameter's value to “‐ ‐ ‐ ‐” by simultaneously
pressing both of the right‐display scroll keys.

Operating Parameters
B-15
Part 1126931_01
2018 Nordson Corporation
57 Schedule 1 Enter Standby
Description:
Used to set the time that the melter will enter the standby mode during schedule
1.
Value:
0000 to 2359, ‐ ‐ ‐ ‐
Resolution:
1 minute
Default Value:
‐ ‐ ‐ ‐
Format:
Hour, Hour: Minute, Minute
Use:
Set the time that the melter will enter the standby mode during schedule 1.
To disable this parameter, set the parameter's value to “‐ ‐ ‐ ‐” by simultaneously
pressing both of the right‐display scroll keys.
Note: Do not set an enter standby time that is outside of the time period defined
by the schedule's heater on and off time. The melter cannot enter the standby
mode when the heaters are off.
58 Schedule 1 Exit Standby
Description:
Used to set the time that the melter will exit the standby mode during schedule 1.
Value:
0000 to 2359, ‐ ‐ ‐ ‐
Resolution:
1 minute
Default Value:
‐ ‐ ‐ ‐
Format:
Hour, Hour: Minute, Minute
Use:
Set the time that the melter will exit the standby mode during schedule 1.
To disable this parameter, set the parameter's value to “‐ ‐ ‐ ‐” by simultaneously
pressing both of the right‐display scroll keys.
Note: Do not set an exit standby time that is outside of the time period defined
by the schedule's heater on and off time. The melter cannot enter the standby
mode when the heaters are off.
60 Schedule 2 Heaters On
Description:
Used to set the time that the clock will turn on the heaters during schedule 2.
Value:
0000 to 2359, ‐ ‐ ‐ ‐
Resolution:
1 minute
Default Value:
‐ ‐ ‐ ‐
Format:
Hours, Hour: Minute, Minute
Use:
Set the desired time for the heaters to turn on.
To disable this parameter, set the parameter's value to “‐ ‐ ‐ ‐” by simultaneously
pressing both of the right‐display scroll keys.

Operating Parameters
B-16
Part 1126931_01
2018 Nordson Corporation
Seven‐day Clock (contd)
61 Schedule 2 Heaters Off
Description:
Used to set the time that the clock will turn off the heaters during schedule 2.
Value:
0000 to 2359, ‐ ‐ ‐ ‐
Resolution:
1 minute
Default Value:
‐ ‐ ‐ ‐
Format:
Hours, Hour: Minute, Minute
Use:
To disable this parameter, set the parameter's value to “‐ ‐ ‐ ‐” by simultaneously
pressing both of the right‐display scroll keys.
62 Schedule 2 Enter Standby
Description:
Used to set the time that the melter will enter the standby mode during schedule
2.
Value:
0000 to 2359, ‐ ‐ ‐ ‐
Resolution:
1 minute
Default Value:
‐ ‐ ‐ ‐
Format:
Hour, Hour: Minute, Minute
Use:
Set the time that the melter will enter the standby mode during schedule 2.
To disable this parameter, set the parameter's value to “‐ ‐ ‐ ‐” by simultaneously
pressing both of the right‐display scroll keys.
Note: Do not set an enter standby time that is outside of the time period defined
by the schedule's heater on and off time. The melter cannot enter the standby
mode when the heaters are off.
63 Schedule 2 Exit Standby
Description:
Used to set the time that the melter will exit the standby mode during schedule 2.
Value:
0000 to 2359, ‐ ‐ ‐ ‐
Resolution:
1 minute
Default Value:
‐ ‐ ‐ ‐
Format:
Hour, Hour: Minute, Minute
Use:
Set the time that the melter will exit the standby mode during schedule 2.
To disable this parameter, set the parameter's value to “‐ ‐ ‐ ‐” by simultaneously
pressing both of the right‐display scroll keys.
Note: Do not set an exit standby time that is outside of the time period defined
by the schedule's heater on and off time. The melter cannot enter the standby
mode when the heaters are off.