DuraBlue II Customer Product Manual - 第200页

Configuration Manager desktop icon Melter Communications C-6 Part 1126931_01  2018 Nordson Corporation Using Nordson Configuration Manager Configuration Manager is launched from your Windows desktop using the icon shown…

100%1 / 206
11
22
00
44
55
33
66
99
Serial port
Melter Communications
C-5
Part 1126931_01
2018 Nordson Corporation
Connecting the PC and the Melter
Connect a serial cable between the PC COM port (selected during the
software installation routine) and the serial port connection (COM port) on
your melter's control panel.
Configuration Manager
desktop icon
Melter Communications
C-6
Part 1126931_01
2018 Nordson Corporation
Using Nordson Configuration Manager
Configuration Manager is launched from your Windows desktop using the
icon shown to the left.
Use Configuration Manager when you want to...
copy melter settings from one melter to another melter
create and save more than one version of melter settings
upgrade or restore a melter's firmware
Configuration Manager communicates with your melter through a PC
connected to your melter's serial port. Once connected, Configuration
Manager offers the choice of saving settings, restoring settings, or upgrading
the melter's firmware.
The first time you download and install Configuration Manager, the latest
version of the melter's firmware is also downloaded.
Saving and Restoring Melter Settings
Saving settings copies all current set‐point and operating parameter values
to your PC. Saved settings can be transferred back to the same melter or to
any other compatible Blue Series adhesive melter.
To save melter settings
1. Place the melter into the configuration mode by simultaneously pressing
the Standby and Setup keys.
COnF” appears in the right display.
2. Double‐click the NCM icon on the Windows desktop.
The NCM dialog box appears.
3. Click Select Device.
The Select Product dialog box appears.
4. Select your melter from the list, and then click Ok.
The Select COM Port dialog box appears.
5. Select the COM port you are using to connect to the melter, and then
click Ok.
The PC and melter establish communications and a picture of the melter
you selected appears in the device status area. The right side of the
status area indicates “CONNECTED”.
6. Click Save Settings.
The Save As dialog box appears.
NOTE: The default location for saving settings files is Windows My
Documents folder. To avoid loosing saved settings files, Nordson
Corporation recommends that you do not change the default save
location.
Melter Communications
C-7
Part 1126931_01
2018 Nordson Corporation
7. Type a file name to identify the group of settings you are saving, and then
click Save.
The save settings progress bar indicates the status of the save. When the
save is complete, the melter automatically returns to the scan mode.
NOTE: If you are using the NCM to save multiple variations of melter
settings, use a file naming convention that will allow you to easily
associate each settings file (.ncm extension) with its related process or
end‐use.
8. Click Ok to close the NCM.
To restore melter settings
1. Follow steps 1 through 5 of To save melter settings.
2. Click Restore Settings.
The Open dialog box appears.
3. Select the settings file (.ncm extension) that you want to restore, and then
click Open.
The Restore Settings progress bar indicates the status of the restore.
When the restore is complete, the melter automatically returns to the
scan mode.
Upgrading or Restoring Melter Firmware
Use the NCM to upgrade your melter to a newer version of firmware or reload
the current version of the firmware. The version of Blue Series adhesive
melter firmware that is currently available is posted on the Internet at
http://emanuals.nordson.com/adhesives/software/BlueSeriesSoftware.html.
NOTE: The version of firmware that is loaded on your melter appears on the
control panel when the melter is first switched on.
During the upgrade process, all current melter settings are downloaded and
saved on your PC. After upgrading or restoring a melter's firmware, you can
use the NCM to restore the pre‐upgrade settings.
CAUTION! The upgrade process returns the melter's settings to factory
configuration, with the exception that current heater hours data is saved.
Data in both the fault log and the change log is lost after upgrading the
firmware.