DuraBlue II Customer Product Manual - 第203页

Melter Communications C-9 Part 1126931_01  2018 Nordson Corporation To upgrade or reload melter firmware (contd) CAUTION! Once the uprade progress bar appears, do not interrupt the upgrade process for any reason. Interu…

100%1 / 206
Melter Communications
C-8
Part 1126931_01
2018 Nordson Corporation
Upgrading or Restoring Melter Firmware (contd)
To upgrade or reload melter firmware
1. Connect your PC to the melter. Refer to Connecting the PC and the
Melter earlier in this guide.
2. Place the melter into the upgrade mode by switching the melter off and
then on again, and then immediately pressing and holding both the
Setup and left display Scroll key.
UPLOAd appears in the right display.
3. Double‐click the NCM icon on the Windows desktop.
The NCM dialog box appears.
4. Click Select.
The device dialog box appears.
5. Select your melter from the list, and then click Ok.
The Select COM Port dialog box appears.
6. Select the COM port you are using to connect to the melter, and then
click Ok.
The PC and melter establish communications and a picture of the melter
you selected appears in the device status area. The right side of the
status area indicates Connected.
7. Click Upgrade.
The Select Upgrade dialog box appears.
8. In the Available Upgrades list, select the firmware version you want to
upload to the melter, and then click Ok.
The upgrade warning message appears.
9. Click OK.
The Upgrade in Progress dialog box appears. The upgrade can take as
long as 12 minutes. When the upgrade is complete, the Success dialog
box appears and the melter restarts.
Melter Communications
C-9
Part 1126931_01
2018 Nordson Corporation
To upgrade or reload melter firmware (contd)
CAUTION! Once the uprade progress bar appears, do not interrupt the
upgrade process for any reason. Interupting the upgrade can corrupt the
melter's firmware, which will require replacement of the IC chip
(IC service kit P/N 1018817).
10. Click OK.
The communications link between the melter and the PC is terminated.
11. Do one of the following:
To restore pre‐upgrade melter settings, go to To restore pre‐upgrade
melter settings.
To close the NCM, click Exit.
To restore melter settings other than the settings that were in use by
the melter before the upgrade, go to Saving and Restoring Melter
Settings earlier in this guide.
To restore pre‐upgrade melter settings
1. Place the melter into the configuration mode by simultaneously pressing
the Standby and Setup keys.
COnF” appears in the right display.
2. Click Connect.
The Select COM Port dialog box appears.
3. Select the COM port you are using to connect to the melter, and then
click Ok.
The PC and melter establish communications and a picture of the melter
you selected appears in the device status area. The right side of the
status area indicates “CONNECTED”.
4. Click Restore Pre‐Upgrade Settings.
The pre‐upgrade settings are restored and the melter returns to the scan
mode.
5. Click Exit to close the NCM.
Melter Communications
C-10
Part 1126931_01
2018 Nordson Corporation
Troubleshooting
Using Nordson Configuration Manager
Symptom/Message Action
After selecting a device and the COM port, an Access Denied
message appears.
PC‐to‐Blue communications may be running or another
application may be using the COM port. Close Internet Explorer
and end the communications connection (if prompted). Close all
other applications.
Melter in UPLOAd mode, the update process has not been
initiated, and you want to stop and exit the UPLOAd mode, but you
cannot get the melter out of UPLOAd.
Cycle power to the melter at the local power disconnect switch.
CAUTION: Ensure that the firmware update process is not running
before taking power off of the melter.
UPLOAd does not appear on the melter's display when you press
the Setup and left display scroll keys.
You must cycle the control switch while holding the Setup and left
display scroll keys.
Attempted a firmware update, but the melter display still indicates
UPLOAd.
OR
Attempted a firmware update, but the PC has stopped responding
or was interrupted during the update process.
Using the local power disconnect switch, cycle power to the
melter, and then re‐attempt the update.
If the update is unsuccessful or the melter will not reboot, the
central processor chip may be corrupted. Replace the CPU board.