Installation 3-30 Part 1126931_01  2018 Nordson Corporation Set Up Inputs/Outputs (contd) Table 3‐6 Input/Output Data (contd) Item Description Operating Parameter Control Options Terminals Notes 13 Motor 3 remote start …

100%1 / 206
Installation
3-29
Part 1126931_01
2018 Nordson Corporation
Table 3‐6 Input/Output Data (contd)
Item Description
Operating
Parameter
Control Options Terminals Notes
6 Standard output 2 41 Same as parameter 40
(Default=3)
XI:11, XI:12
7 Standard output 3 42 Same as parameter 40
(Default=4)
XI:13, XI:14
8 Key‐to‐line
0-10V input
XI:15 (+),
XI:16 (-)
Refer to Setting
Up Gear‐to‐Line
Operation
9 Motor 1
remote start
XI:17, XI:18 Connect a
momentary,
normally open
contact to the
terminals.
10 Motor 1
remote stop
XI:19, XI:20 Connect a
momentary,
normally open
contact to the
terminals.
11 Motor 2
remote start
XI:21, XI:22 Connect a
momentary,
normally open
contact to the
terminals.
12 Motor 2
remote stop
XI:23, XI:24 Connect a
momentary,
normally open
contact to the
terminals.
Continued...
Installation
3-30
Part 1126931_01
2018 Nordson Corporation
Set Up Inputs/Outputs (contd)
Table 3‐6 Input/Output Data
(contd)
Item Description
Operating
Parameter
Control Options Terminals Notes
13 Motor 3
remote start
(See Note J)
XI:29, XI:30 Connect a
momentary,
normally open
contact to the
terminals.
14 Motor 3
remote stop
(See Note J)
XI:31, XI:32 Connect a
momentary,
normally open
contact to the
terminals.
15 Motor 4
remote start
(See Note J)
XI:33, XI:34 Connect a
momentary,
normally open
contact to the
terminals.
16 Motor 4
remote stop
(See Note J)
XI:35, XI:36 Connect a
momentary,
normally open
contact to the
terminals.
17 Motor drive 1
running (optional)
XI:25, XI:26 Refer to Setting
Up Motor Run
Status Monitoring.
18 Motor drive 2
running (optional)
XI:27, XI:28
19 Motor drive 3
running (optional)
(See Note J)
XI:37, XI:38 Refer to Setting
Up Motor Run
Status Monitoring.
20 Motor drive 4
running (optional)
(See Note J)
XI:39, XI:40
J: Motors 3 and 4 are present only on three/four pump or 100L melters.
Installation
3-31
Part 1126931_01
2018 Nordson Corporation
Setting Up Gear‐to‐Line Operation
If you want to use the gear‐to‐line capability, install a (customer‐supplied)
line‐speed signal generator to measure the speed of the production line. The
AltaBlue motor control accepts a 0-10 VDC analog input signal.
NOTE: Nordson offers a 0-10 VDC line‐speed signal generator. Refer to
Optional Accessories in Section7, Parts, for the part number.
To use the gear‐to‐line capability, connect a 0-10 VDC signal from a
customer‐supplied line‐speed signal generator to the appropriate terminals
on terminal block XI inside the electrical enclosure. See Figure 3‐6 for the
location of terminal block XI. Refer to Table 3‐6 for the terminal numbers that
correspond to each input/output.