DuraBlue II Customer Product Manual - 第62页
Installation 3-34 Part 1126931_01 2018 Nordson Corporation Installing Optional Equipment Each item of optional equipment is shipped with instructions for installing and operating the equipment. Refer to Section 7, Part…

DuraBlue‐II service kit motor drive
keypad
PAR 430
Analog Input 1
REM AUTO SET
8
Installation
3-33
Part 1126931_01
2018 Nordson Corporation
Programming
This parameter comes pre‐set at the factory.
Use the service kit motor drive keypad, PN 7411739 to set up the motor run
status monitoring for each motor. Refer to Changing a Motor Drive Parameter
in Section 6, Troubleshooting, for a detailed procedure for changing a motor
drive parameter.
1. Press
(ENT) until the Group Screen is displayed.
2. Press
(UP) until Group 4 is displayed.
3. Press
(ENT) to access I/O parameters.
4. Press
(UP) to select the parameter until “P420.00” is displayed.
5. Press
(ENT) to select the sub parameter.
6. Press
(UP) to select P420.01.
7. Press
(ENT) to set parameter.
8. Press
(UP) to change parameter until 51 is displayed.
9. Press
(ENT) >3S to save parameters to memory.

Installation
3-34
Part 1126931_01
2018 Nordson Corporation
Installing Optional Equipment
Each item of optional equipment is shipped with instructions for installing and
operating the equipment. Refer to Section 7, Parts, for equipment part
numbers.
Connecting an Applicator Driver, Pattern
Controller, or Timer
If applicable, complete the melter installation by connecting the applicators to
the desired applicator driver, pattern controller, or timer. Refer to the product
manual provided with the device for information about installing and
operating the equipment.
Flushing the Melter
Before using the melter for production, it should be flushed to remove any
residue left over from factory‐testing. Flushing the melter is accomplished by
processing a minimum of one tank volume of hot melt through the melter,
hoses, and applicators.
Refer to Section 4, Operation, for information about filling the tank and
operating the melter.
Disposing of Melter
When your Nordson product has reached the end of its useful life, dispose of
it in accordance with local regulations.

Operation
4-1
Part 1126931_01
2018 Nordson Corporation
Section 4
Operation
WARNING! Allow only qualified personnel to perform the following tasks.
Follow the safety instructions in this document and all other related
documentation.
This section provides information about the following operator‐level tasks:
Filling the melter tank
Starting the melter
(Optional) Adjusting the speed of the motor(s)
(Optional) Adjusting material pressure
Monitoring melter operation
Adjusting the operating temperature of heated components
Using the melter function keys
Shutting the melter down
Most of the controls described in this section are located on the
control panel. Refer to Key Components in Section 2, Introduction, for
the location of the controls and indicators described in this section.
Additional Information
This section presents operating procedures in their most commonly used
form. Procedural variations or special considerations are explained in the
additional information table that follows most procedures. Where applicable,
some table entries also contain cross‐reference information. Additional
information tables are indicated by the symbol shown to the left.