4.2.5 Set Pitch Returning Operation Procedure (1) Press the button to select the lane. (2) Press the button and at the same time, press the button. (3) W ithin 2 seconds, release your nger from the button only and keep …

4.2.4 Minimum Pitch Feed Operation
This is used when the tape with a new reel is to be set on the tape feeder and the
chip component center is aligned with the pick-up position.
This feeds the tape xed with a minimum pitch.
Note
(a) According to the set feed pitch, the minimum feed pitch is changed.
•
When the feed pitch is 1 mm : Minimum feed pitch = 1 mm
•
When the feed pitch is 2 mm or more : Minimum feed pitch = 2 mm
(b) In the case of minimum feed pitch, the tape is not fed in the rst start
operation. This is because servo-ON processing is performed for the tape
feed servo-motor to return to the home position from any position.
In this case, repeat the operation within 1 second.
The servo ON condition is continued for 1 second.
Procedure
(1) Press the button to select the lane.
(2) Using the ON/OF operation of the
button, execute the minimum feed
pitch.
Repeating the ON/OFF operation of the
button can continue the
minimum feed pitch.
1504-001
4.2 Operation of Operation Panel
OM-1833
4-4

4.2.5 Set Pitch Returning Operation
Procedure
(1) Press the button to select the lane.
(2) Press the
button and at the same time, press the button.
(3) Within 2 seconds, release your nger from the
button only and keep
pressing the
button.
(4) Using the ON/OFF operation of the
button, execute the 1 pitch feed
operation.
Repeating the ON/OFF operation of the button can continue the feed
operation.
(5) Release your nger from the
button.
1504-001
4.2 Operation of Operation Panel
OM-1833
4-5

4.2.6 Minimum Pitch Returning Operation
Note
In the case of the minimum pitch return, the tape is not fed in the rst start
operation. This is because servo-ON processing is performed for the tape feed
servo-motor to return to the home position from any other position.
In this case, repeat the operation within 1 second.
The servo ON condition is continued for 1 second.
Procedure
(1) Press the button to select the lane.
(2) Press the
button and at the same time, press the button.
(3) Within 2 seconds, release your nger from the
button only and keep
pressing the
button.
(4) Using the ON/OF operation of the
button, execute the minimum pitch
returning operation.
Repeating the ON/OFF operation of the
button can continue the
minimum pitch returning operation.
(5) Release your nger from the
button.
1504-001
4.2 Operation of Operation Panel
OM-1833