5.4.4 T ape Feeding Unit Sprocket (2) (Oiling port) Sprocket (2) (Tip Gear) Every Three Months Cleaning : Remove anything attached to the tooth tips using a rag soaked in alcohol or cotton applicator. Every Three Months …

100%1 / 122
Flat End
Tape Present/Adsent Sensor
Every Three Months Cleaning :
Remove the cover from the loading unit
and remove any debris or dust using the
air gun.
Every Three Months Lubrication :
Remove the cover from the loading unit
and apply Molynoc Grease API on the
spur gears using the oiling jig.
The spur gears on the right
side are used for lane #1 and
the spur gears on the left side
are used for lane #2.
Note
Fig. E7
1504-001
5.4 Maintenance Spots
OM-1833
5-9
5.4.4 Tape Feeding Unit
Sprocket (2) (Oiling port)Sprocket (2) (Tip Gear)
Every Three Months Cleaning :
Remove anything attached to the tooth tips
using a rag soaked in alcohol or cotton
applicator.
Every Three Months Lubrication :
Fill Molynoc Grease API from the oil port
using the oiling jig.
The upper oil port is used for
lane #1 and the lower oil port
is used for lane #2.
Sprocket (1) (Oiling port)
Sprocket (3) (Tip Gear)
Every Three Months Cleaning :
Remove anything attached to the tooth tips
using a rag soaked in alcohol or cotton
applicator.
Every Three Months Lubrication :
Fill Molynoc Grease API from the oil port
using the oiling jig.
The upper oil port is used for
lane #1 and the lower oil port
is used for lane #2.
Note
Note
Fig. E8
1504-001
5.4 Maintenance Spots
OM-1833
5-10
5.5 Maintenance Method
5.5.1 Cover Removal and Attachment
5.5.1.1 Cover LA Removal Procedure
Procedure
(1) Remove the countersunk set screw for xing the cover LA (4 locations).
Screw Hole
(4 locations)
Fig. E9
(2) Slide he cover LA in the arrow direction.
Fig. E10
(3) Then slide the cover LA in the arrow direction (upper) to remove.
Fig. E11
1504-001
5.5 Maintenance Method
OM-1833