YAMAHA errer code-a - 第14页
Ea - 14 ERROR MESSAGES LIST Ea Ea00665 Ea00666 Ea00667 Ea00668 Ea00669 /B Ea00669 /A Ea00670 /B Ea00670 /A Ea00671 Ea00672 Ea00673 /B Ea00673 /A Ea00674 DA T A ERROR Failed to distribute nozzles. DA T A ERROR Failed to d…

Ea -13
ERROR MESSAGES LIST
Ea
Ea00602
Ea00603
Ea00604
Ea00605
Ea00610
Ea00611
Ea00620
Ea00621
Ea00622
Ea00623
Ea00624
Ea00625
Ea00642
Ea00643
DATA ERROR
The number of used nozzle exceeds your possession.
Machine 1
Nozzle_type 2
DATA ERROR
The number of component data exceeds system limit.
Machine 2
DATA ERROR
The number of mount data exceeds system limit.
Machine 2
DATA ERROR
The nozzle is not distributed to head.
Machine SM120
•Some nozzles cannot pick the interfering component.
Check the nozzle type of each components.
•Luck of nozzle number. Check the nozzle number and
head spec. inf..
Failed to access feeder quantity data file.
Failed to access nozzle quantity data file.
DATA ERROR
No component data exists.
Machine 2
PCB CUK93001
Component 150
DATA ERROR
No fiducial data exists for the mount data.
Machine 2
PCB CUK93001
Mount 765
Fiducial 1
DATA ERROR
No mark data exists.
Machine 2
PCB CUK93001
Mark 1
DATA ERROR
No badmark data exists for the mount data.
Machine 2
PCB CUK93001
dispense 765
Badmark 1
DATA ERROR
No fiducial data exists for the dispense data.
Machine 2
PCB CUK93001
dispense 765
Fiducial 1
DATA ERROR
No badmark data exists for the dispense data.
Machine 2
PCB CUK93001
dispense 765
Badmark 1
Dispense machine is not exist.
Failed to open dispense information.
(meaning)The number of nozzles planned for use exceeds the num-
ber available for processing.
(cause)The number of nozzles used to manufacture the data cur-
rently being planned is not enough for the actual processing.
(remedy)If the setting for the number used in processing is wrong,
correct it in the machine configuration. If there are actually too few
nozzles, purchase more, or use the YV112 to create data for the
places where nozzles are to be secured and used.
(meaning)The number of component data exceeds the specifica-
tions.
(cause)Components assigned to the specified machine exceed the
specifications.
(remedy)Shift some of the component data assigned to that ma-
chine to another machine.
(meaning)The number of mounting data exceeds the specifications
for that machine.
(cause)Same as above.
(remedy)Set up the specified components on another machine.
(meaning)In no-nozzle change machine, nozzle is not distributed
to each head.
(cause)Some component is too big size to interfere to nearest
nozzle(head).
(remedy)Check the component size and nozzle type. Check the
number of nozzle and the setting of head spec. inf..
(meaning)An error occurred in accessing the data file containing
the number of feeders to be used.
(cause)There is a problem with the hard disk
(remedy)Try creating the data again from the beginning. If it cannot
be recovered, contact the manufacturer.
(meaning)An error occurred in accessing the data file containing
the number of feeders to be used.
(cause) There is a problem with the hard disk
(remedy)Try creating the data again from the beginning. If it cannot
be recovered, contact the manufacturer.
(meaning)There is no component data.
(cause)Same as above.
(remedy)Create the specified component data.
(meaning)There is no fiducial data.
(cause)Same as above.
(remedy)Create the specified fiducial data.
(meaning)There is no mark data.
(cause)Same as above.
(remedy)Create the mark data.
(meaning)There is no badmark data.
(cause) Same as above.
(remedy)Create the specified badmark data.
(meaning)There is no fiducial data.
(cause)Same as above.
(remedy)Create the specified fiducial data.
(meaning)There is no badmark data.
(cause)Same as above.
(remedy)Create the specified badmark data.
Please select the "Exist" of Dispense Head in MCH_CONFIG.
Fail to make the temporary file.
Ea00645
Ea00647
Ea00648
Ea00649
Ea00650
Ea00651
Ea00653
Ea00658
Ea00660
Ea00661
Ea00662
Ea00663
Ea00664
CAUTION: Now going to convert the data from "Exec" to
"Note" in Mount, Block repeat, Local fiducial and Local
badmark. So, "Exec"data will be deleted. Push the [EN-
TER] key to execute. Push the [ESC] key to cancel this
operation.
"Note" data need to execute the convert from block con-
verted data to original data is not exist.
Machine YV112
CAUTION: Amount of Mount data that executed block
conversion exceeded 2500. Amount of data exceeded
the limit for auto-running. Reduce the number of data.
Amount of 'Mount Data", 'Component Info,' , 'Mark Infor-
mation', 'Block Repeat', 'Fiducial Mark', 'PreDispense' and
'DotDispense' cannot exceed 2560. Push the [ENTER]
key to continue. Push the [ESC] key to cancel this opera-
tion.
There is only one "Exec" data in Block repeat.
PCB DATA ERRORNFORMATION ERROR
No alignment module for the component.
Machine 2
PCB CUK93001
Component 1
PCB DATA ERROR Feeder Information
No dump station for the component. Or the table of the
dumpstation is different from the one of the component.
Machine 2
PCB CUK93001
Component 1
DOT DISPENSE SORT TIMEOUT ERROR
Dispense sort was interrupted by time out error. Dispense
sort was finished, but it is contained the data that stopper
may interfere with other dispense data.
Please check the following:
•Illegal Diameter, Stopper and Pitch data of the nozzle
spec.
COMMAND ERROR
1. [ADJUST ASSISTANT] command is not available for a
component with positive "FixCmpRef."
2. [DRAW THE SHAPE(CMP)] command is not available
for a component with positive "FixCmpRef."
DATA ERROR
Failed to quote component details from its Data Base.
Component 150
specifies an illegal database number.
CheckPoint: DataBase Number
DATA ERROR
Failed to quote mark details from its Data Base.
Mark 150
specifies an illegal database number.
CheckPoint: DataBase Number
DATA ERROR
Failed to set up component or mark information from
Database. MAIN WINDOW should be component info. or
mark info.
Or indicated database may not exist.
Or failed to set up component or mark information into
Database. The indicated record may be protected by pass
word level.
FILE ERROR
Failed to read PCB Data.
DATA ERROR
Failed to set up Fixed feeders at its position.
Component 150
specifies an impossible set position.
The component that feeder position is "Teaching" is ex-
ist.
Change the "FeederPosition" into "Automatic".
Change the "MOUNT DATA CONDITION" into "FEEDER
MOVE".
This is a warning message.
Check the existence of "Note" data in Mount, Block repeat, Local
fiducial, Local badmark.
Calculated mount data over 2500. So check and decrease the
amount of Mount, Block repeat, Local fiducial and Local badmark
within 2560.
This PCB data is not for block. Block data need more than two "Exec"
data in Block repeat.
(meaning)Suitable alignment module for the component is not
equipped on the machine.
(cause)There is an error in the setting in the alignment module for
the component or the component must be mounted by the other
machine.
(remedy)Correct the erroneous setting.
(meaning)Though the component must be dumped to the dump
station, the machine is not equipped with a dump station properly.
(cause)There is an error in the setting in the dump way for the com-
ponent or the machine data. Or the table of the dump station is
different from the table where the component is fixed.
(remedy)Correct the erroneous setting.
(meaning)Dispense sort was interrupted by timeout error.
(cause)Illegal Diameter, Stopper and Pitch data of the nozzle spec.
(remedy)Please check the nozzle spec data.
(meaning)These commands are not available for component with
positive "FixCmpRef.".
(remedy)Use these commands to components data in PCB
[STATIC_COMPONENTS].
(meaning)An error occurred when setting data from the database.
(cause)There is no information in the database corresponding to
the specified database number.
(remedy)Use the database list command to check the existing da-
tabase numbers, and specify an existing number.
(meaning)An error occurred when setting data from the database.
(cause)There is no database corresponding to the specified data-
base.
(remedy)Use the database list command to check the existing da-
tabase numbers, and specify an existing number.
(meaning) Data cannot be set from database.
(cause) An attempt was made to use database setting function on
screen other than component information or mark information
screen.
(remedy) Use [F3] key to switch to component information or mark
information screen.
(meaning)An error occurred in reading the PCB data.
(cause)ÅgPCB data with an asterisk (*) was selected; a machine
which has not been registered was selected; or the PCB data has
been destroyed.
(remedy)In the first two cases, correct the operation. In the last case,
copy the data from the backup disk.
(meaning)An error occurred in attaching the fixed feeder because
of the data created.
(cause)Another fixed feeder already exists in that position, so there
is no space to attach the specified feeder.
(remedy)Find the feeder which is interfering with the fixed feeder,
and remove it, or delete the specification of the fixed feeder which is
causing the problem. If the component that feeder position is
"TEACHING", change to "AUTOMATIC" and execute the optimiza-
tion.

Ea -14
ERROR MESSAGES LIST
Ea
Ea00665
Ea00666
Ea00667
Ea00668
Ea00669
/B
Ea00669
/A
Ea00670
/B
Ea00670
/A
Ea00671
Ea00672
Ea00673
/B
Ea00673
/A
Ea00674
DATA ERROR
Failed to distribute nozzles.
DATA ERROR
Failed to distribute mount data.
FILE ERROR
Failed to write PCB Data.
Failed to read Machine Equipment Data.
DATA GENERATOR OBJECT ERROR
Dummy file for DATA GENERATOR doesn't exist.
Possible cause :
1.Object PCB hasn't been selected.
2.Dummy file was deleted because of error.
Counter measures :
1.Select PCB.
2.Select [A1 OBJECT SELECTION] and exit.
DATA GENERATOR OBJECT ERROR
Dummy file for DATA GENERATOR doesn't exist.
Possible cause :
1.Object PCB or line hasn't been selected..
2.Dummy file was deleted because of error.
Counter measures :
1.Select PCB and line.
2.Select [A1 OBJECT SELECTION] and exit.
DATA GENERATOR OBJECT ERROR
This command is not available until you select PCB data.
DATA GENERATOR OBJECT ERROR
This command is not available until you select PCB data
and line.
You have not specified a Machine Number. Please se-
lect, at least, one number.
The dummy file for current object PCB will be deleted.
Will you continue? To abort this process, press [ESC] key.
Nozzle settings are shown below.
A TABLE:[Upper = Head No., Lower = Nozzle Type]
Head 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Nzl. 1 1 1 2 2 2 2 2 2 2 2 3 3 4 4 5
B TABLE:[Upper = Head No., Lower = Nozzle Type]
Head 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Nzl. 1 1 1 2 2 2 2 2 2 2 2 3 3 4 4 5
Nozzle settings are shown below.
Machine 2
A TABLE:[Upper = Head No., Lower = Nozzle Type]
Head 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Nzl. 1 1 1 2 2 2 2 2 2 2 2 3 3 4 4 5
B TABLE:[Upper = Head No., Lower = Nozzle Type]
Head 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Nzl. 1 1 1 2 2 2 2 2 2 2 2 3 3 4 4 5
This PCB is already selected.
(meaning)An error occurred in the nozzle layout when the data was
created.
(cause)If a feeder has already been fixed in that position, the nozzle
could not be positioned in a place where it is possible to pick up
components.
(remedy)Change the position of the fixed feeder.
(meaning)An error occurred in the layout in the mounting data.
(cause)If the data is too complex, an error occurs in the mounting
data and the feeders cannot be positioned.
(remedy)Shift part of the data to another machine.
(meaning)An error occurred in writing the PCB data.
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. In any other case, check to see how
often the problem occurs, and contact the manufacturer.
(meaning)An error occurred when reading the model information.
(cause)The software versions do not match, or the model setting
does not match the registered machine data.
(remedy)Register the machine data again and check the versions.
If the versions are different, contact the manufacturer.
(meaning)The dummy file which has to serve as a target for creat-
ing the data does not exist.
(cause)The PCB name has not been selected; the dummy file has
been erroneously deleted; or no line has been selected
(remedy)Select the PCB line.
(meaning)Because PCB data is not selected, the command is not
available.
(cause)Same as above.
(remedy)Select PCB data before executing the command.
(meaning)Because PCB data,line is not selected, the command is
not available.
(cause)Same as above.
(remedy)Select PCB, line before executing the command.
(meaning)The machine number which serves as the target for cre-
ating data has not been selected.
(cause)Same as above.
(remedy)Select the machine.
(meaning)The dummy file of PCB data which currently serves as
the target for creating data will be lost if the command about to be
executed is actually executed.
(cause)Same as above.
(remedy)If losing the dummy file will cause problems, press the
ESC key. If the dummy file can be deleted, press any other key.
(meaning)This shows how the nozzles will be attached as speci-
fied by the PCB data, following creation of the data.
(cause)None
(remedy)None
(meaning)The PCB you are trying to select has already been se-
lected.
(cause)Same as above.
(remedy)None
Ea00675
Ea00676
Ea00677
Ea00678
Ea00679
Ea00680
Ea00681
Ea00682
Ea00683
Ea00684
/B
Ea00684
/A
Ea00690
You cannot select any more PCB.
No type of nozzle can pickup the component.
Component 150
Check Point:
Required Nozzle(Component data)
Nozzle Information
No head to attach the nozzle to in order to pickup the
component.
Component 150
Check Point:
Nozzle Setting (In case of NO_NOZZLE_SUGGESTION)
Feeder Position (In case of fixed feeder)
Un-used Head (In case of 112)
Failed to distribute feeder.
No place to fix the component.
Component 150
Check Point: Fix the position of the component.
Failed to copy PCB data.
NOZZLE SET INFORMATION ERROR
The selected nozzle cannot be fixed to this head.
COMMAND ERROR
[A2 NOZZLE SETTING] is available only in the case that
you select EDITING for NZL.CONDITION SEL.
But you can change to EDITING temporarily. (while you
don't exit from making data mode) If you want to change,
push the [ENTER] key. If you don't want to change, push
any other key.
No head available to handle the component.
Component 150
Check Point:
Component Size
Required Nozzle(Component data)
Wait a moment while
copying PCB data....
Nozzle settings are shown below.
XY TABLE[Upper = Head No., Lower = Nozzle Type]
Head 1 2 3 4 5 6 7 8
Nzl. 1 1 1 2 2 2 2 2
Nozzle settings are shown below.
Machine 2
XY TABLE[Upper = Head No., Lower = Nozzle Type]
Head 1 2 3 4 5 6 7 8
Nzl. 1 1 1 2 2 2 2 2
There is no more than two mount data.
In this condition, this function is not available. You can not
select "REPLACE" or "MULTIPLY COMPONENT" when
Component data is not available.
(meaning)The number of PCBs you are trying to select as fixed
PCBs for data creation exceeds the allowable number
(cause)An attempt was made to register five or more PCBs as fixed
PCBs.
(remedy)Select one of the PCBs already registered as a fixed PCB
and cancel it.
(meaning)An attempt was made to pick up components without an
appropriate nozzle. |
(cause)The setting in the component data for the nozzles to be used
is wrong.
(remedy)Go back to the editing screen and check the component
data.
(meaning)There is no head to which a nozzle which can be used to
pick up the components can be attached.
(cause)If the setting for the recommended nozzle is set to "None",
the nozzles has already been decided by the user, and there is no
empty space; or a fixed feeder is being used, and the appropriate
nozzles cannot be attached to a head which will reach that feeder.
Also, it may be that a head has been installed which cannot move
into the work area, so the nozzle cannot be attached to it.
(remedy)Go back to the editing screen and change the nozzle posi-
tion or the feeder position.
(meaning)An error occurred in the feeder layout when creating the
data.
(cause)Because the data is too complex, ultimately there are no
more places where feeders can be attached. Or there are too many
feeders, so that the layout is logistically impossible
(remedy)Try fixing the setting position for the component where the
problem is occurring, or shift that component to another machine.
(meaning)An error occurred in copying the PCB data.
(cause) There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. In any other case, check to see how
often the problem occurs, and contact the manufacturer.
(meaning)When the nozzle configuration was edited, a setting was
used which attaches a nozzle to a head which can not accommo-
date that nozzle.
(cause)Same as above.
(remedy)Do not attach that nozzle to that head.
(meaning)The nozzle setting is possible only when the nozzle set-
ting conditions are edited manually.
(cause)The nozzle setting was selected even though the nozzle
setting conditions must be edited manually.
(remedy)Do not change that setting, or edit the setting conditions
manually.
(meaning)No head exists which can be used with the components.
(cause)Because the components are too big, there is no head to
which an appropriate nozzle can be attached, or there is something
wrong with the component data setting specifying the nozzle to be
used.
(remedy)Go back to the editing screen and check the component
data.
(meaning)PCB data is being copied. This is not an error message.
(cause)None
(remedy)Please wait until the data has been copied.
(meaning)The bulk substitution and component separation functions
cannot be used because there is no data in the placing information.
(cause)No placing information exists.
(remedy)Input the placing data.

Ea -15
ERROR MESSAGES LIST
Ea
Ea00691
Ea00692
Ea00693
Ea00700
Ea00701
Ea00702
Ea00703
Ea00704
Ea00705
Ea00706
Ea00707
Ea00710
There is no more than two componet data.
In this condition, this function is not available. You can not
select "REPLACE" or "MULTIPLY COMPONENT" when
Component data is not available.
There is no more than two mount or component data.
In this condition, this function is not available. You can not
select "RENUMBER COMPONENT" tavailable. when
Component data or Mount data is not available.
Not find new Component number All component number
used
Failed to open component information.
Failed to read component information.
Failed to write component information.
Component information are not selected.
There are components on destination whose name is
same as the one shown below. Would you continue?
Component 3
Component Name R3216
[ESC] key to abort
Other key to continue
The component shown below can not be moved because
it doesn't fulfill the condition.
Component 3
Component Name R3216
The condition for moving component
Not using fixed component reference function
Using feeder optimization
The component shown below uses "Teaching" for "Feeder
Position". Would you continue?
Component 3
Component Name R3216
[ESC] key to abort
Other key to continue
The component is multipled.
Would you define as the alternate component?
[ESC] key is not.
Other key is defined.
Failed to open PCB data.
Machine 2
PCB CUK93001
(meaning)The bulk substitution and component separation func-
tions cannot be used because there is no component data.
(cause)No component information exists.
(remedy)Input the component information.
(meaning)The component number control function cannot be used
because there is no data in the component or placing information.
(cause)There is no component or placing information.
(remedy)Input the component or placing information.
(meaning)Editing is not possible because there is not enough space
available for the remaining component data that has to be regis-
tered.
(cause)There is too much component data registered which is not
needed, or there is too much component data which is actually
being used.
(remedy)If too much unnecessary data has been registered, de-
lete some of it. In any other case, the supplementary editing func-
tion cannot be used.
(meaning)An error occurred in the component in formation file.
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. In any other case, check to see how
often the problem occurs, and contact the manufacturer.
(meaning)An error occurred in the component in formation file.
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. In any other case, check to see how
often the problem occurs, and contact the manufacturer.
(meaning)An error occurred in the component in formation file.
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. In any other case, check to see how
often the problem occurs, and contact the manufacturer.
(meaning)Component information has not been selected.
(cause)Same as above.
(remedy)Select the component information.
(meaning)When components are being moved in the component
information, a component with the same name already exists at
the destination location.
(cause)A component with the same name is already located at that
destination.
(remedy)If having two components with the same name at the des-
tination is not a problem, go ahead with the shift. Otherwise, press
the ESC key to interrupt the shift.
(meaning)In the group of comp. being moved in the component
information screen, a component exists which uses fixed compo-
nent reference function. The component will not be moved.
(cause)Same as above.
(remedy)No remedy.
(meaning)In the group of components being moved on the compo-
nent information screen, feeder position coordinates exist which
are teaching data.
(cause)Same as above.
(remedy)To cancel the movement because of the position coordi-
nate teaching, press the ESC key. To continue the movement press
any other key.
(meaning)When you execute the multiply component, you select
whether using alternate component or not. This component is al-
ready alternated, this function is not used.
(cause)
(remedy)
(meaning)An error occurred when opening the PCB file.
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. In any other case, check to see how
often the problem occurs, and contact the manufacturer.
Ea00711
Ea00712
Ea00713
Ea00715
Ea00720
Ea00721
Ea00722
Ea00723
Ea00724
Ea00725
Ea00726
Failed to read PCB data.
Machine 2
PCB CUK93001
Failed to write PCB data.
Machine 2
PCB CUK93001
Failed to copy PCB data.
Machine 2
PCB CUK93001
Failed to fix the component in PCB.
Machine 2PCB CUK93001
Fixed component information error to open fixed compo-
nent information.
Fixed component information error
Failed to read fixed component information.
Fixed component information error
Failed to write fixed component information.
Fixed component information error
Failed to write fixed component information.
Fixed component information error
Specified fixed component doesn’t exist.
Fixed component information error
“Component Name” are different between PCB data and
fixed component.
Fixed component information error
“Feeder Type” are different between PCB data and fixed
component.
You can’t multiply such a component as
•Using fixed component reference function
•Not using feeder optimization
•Tray components
(meaning)An error occurred when opening the PCB file.
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. In any other case, check to see how
often the problem occurs, and contact the manufacturer.
(meaning)An error occurred when opening the PCB file.
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. In any other case, check to see how
often the problem occurs, and contact the manufacturer.
(meaning)An error occurred when opening the PCB file.
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. In any other case, check to see how
often the problem occurs, and contact the manufacturer.
(meaning)Fixed components in the PCB data cannot be fixed.
(cause)The components cannot be fixed because they interfere with
another feeder which has already been fixed.
(remedy)Do not attempt to fix the components causing the interfer-
ence, or stop trying to fix the components which are currently dis-
played.
(meaning)An error occurred when opening the fixed component in-
formation file.
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. If there is a problem with the disk,
check to see how often the problem occurs, and contact the manu-
facturer.
(meaning)An error occurred when opening the fixed component in-
formation file.
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. If there is a problem with the disk,
check to see how often the problem occurs, and contact the manu-
facturer.
(meaning)An error occurred when opening the fixed component in-
formation file.
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. If there is a problem with the disk,
check to see how often the problem occurs, and contact the manu-
facturer.
(meaning)The specified fixed component information does not ex-
ist.
(cause)There was an error in registering the fixed component refer-
ence number, or the fixed component has not yet been registered.
(remedy)Go back to the editing screen and check the reference
number for the fixed component. If the fixed component has not yet
been registered register it.
(meaning)The component name registered in the PCB data is dif-
ferent from the fixed component being referenced by that compo-
nent.
(cause)Same as above.
(remedy)Change the component name in the PCB data to match
that of the fixed component.
(meaning)The name of the feeder being used in the PCB data is
different from the fixed component feeder being referenced by that
component.
(cause)Same as above.
(remedy)Change the name of the feeder being used in the PCB
data to match that of the fixed component feeder.
(meaning)An attempt was made to input multiple components ref-
erencing fixed components on the component information screen.
(cause)Same as above.
(remedy)There cannot be more than one component referencing
any particular fixed component.