YAMAHA errer code-a - 第15页
Ea - 15 ERROR MESSAGES LIST Ea Ea00691 Ea00692 Ea00693 Ea00700 Ea00701 Ea00702 Ea00703 Ea00704 Ea00705 Ea00706 Ea00707 Ea00710 There is no more than two componet data. In this condition, this function is not available. Y…

Ea -14
ERROR MESSAGES LIST
Ea
Ea00665
Ea00666
Ea00667
Ea00668
Ea00669
/B
Ea00669
/A
Ea00670
/B
Ea00670
/A
Ea00671
Ea00672
Ea00673
/B
Ea00673
/A
Ea00674
DATA ERROR
Failed to distribute nozzles.
DATA ERROR
Failed to distribute mount data.
FILE ERROR
Failed to write PCB Data.
Failed to read Machine Equipment Data.
DATA GENERATOR OBJECT ERROR
Dummy file for DATA GENERATOR doesn't exist.
Possible cause :
1.Object PCB hasn't been selected.
2.Dummy file was deleted because of error.
Counter measures :
1.Select PCB.
2.Select [A1 OBJECT SELECTION] and exit.
DATA GENERATOR OBJECT ERROR
Dummy file for DATA GENERATOR doesn't exist.
Possible cause :
1.Object PCB or line hasn't been selected..
2.Dummy file was deleted because of error.
Counter measures :
1.Select PCB and line.
2.Select [A1 OBJECT SELECTION] and exit.
DATA GENERATOR OBJECT ERROR
This command is not available until you select PCB data.
DATA GENERATOR OBJECT ERROR
This command is not available until you select PCB data
and line.
You have not specified a Machine Number. Please se-
lect, at least, one number.
The dummy file for current object PCB will be deleted.
Will you continue? To abort this process, press [ESC] key.
Nozzle settings are shown below.
A TABLE:[Upper = Head No., Lower = Nozzle Type]
Head 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Nzl. 1 1 1 2 2 2 2 2 2 2 2 3 3 4 4 5
B TABLE:[Upper = Head No., Lower = Nozzle Type]
Head 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Nzl. 1 1 1 2 2 2 2 2 2 2 2 3 3 4 4 5
Nozzle settings are shown below.
Machine 2
A TABLE:[Upper = Head No., Lower = Nozzle Type]
Head 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Nzl. 1 1 1 2 2 2 2 2 2 2 2 3 3 4 4 5
B TABLE:[Upper = Head No., Lower = Nozzle Type]
Head 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Nzl. 1 1 1 2 2 2 2 2 2 2 2 3 3 4 4 5
This PCB is already selected.
(meaning)An error occurred in the nozzle layout when the data was
created.
(cause)If a feeder has already been fixed in that position, the nozzle
could not be positioned in a place where it is possible to pick up
components.
(remedy)Change the position of the fixed feeder.
(meaning)An error occurred in the layout in the mounting data.
(cause)If the data is too complex, an error occurs in the mounting
data and the feeders cannot be positioned.
(remedy)Shift part of the data to another machine.
(meaning)An error occurred in writing the PCB data.
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. In any other case, check to see how
often the problem occurs, and contact the manufacturer.
(meaning)An error occurred when reading the model information.
(cause)The software versions do not match, or the model setting
does not match the registered machine data.
(remedy)Register the machine data again and check the versions.
If the versions are different, contact the manufacturer.
(meaning)The dummy file which has to serve as a target for creat-
ing the data does not exist.
(cause)The PCB name has not been selected; the dummy file has
been erroneously deleted; or no line has been selected
(remedy)Select the PCB line.
(meaning)Because PCB data is not selected, the command is not
available.
(cause)Same as above.
(remedy)Select PCB data before executing the command.
(meaning)Because PCB data,line is not selected, the command is
not available.
(cause)Same as above.
(remedy)Select PCB, line before executing the command.
(meaning)The machine number which serves as the target for cre-
ating data has not been selected.
(cause)Same as above.
(remedy)Select the machine.
(meaning)The dummy file of PCB data which currently serves as
the target for creating data will be lost if the command about to be
executed is actually executed.
(cause)Same as above.
(remedy)If losing the dummy file will cause problems, press the
ESC key. If the dummy file can be deleted, press any other key.
(meaning)This shows how the nozzles will be attached as speci-
fied by the PCB data, following creation of the data.
(cause)None
(remedy)None
(meaning)The PCB you are trying to select has already been se-
lected.
(cause)Same as above.
(remedy)None
Ea00675
Ea00676
Ea00677
Ea00678
Ea00679
Ea00680
Ea00681
Ea00682
Ea00683
Ea00684
/B
Ea00684
/A
Ea00690
You cannot select any more PCB.
No type of nozzle can pickup the component.
Component 150
Check Point:
Required Nozzle(Component data)
Nozzle Information
No head to attach the nozzle to in order to pickup the
component.
Component 150
Check Point:
Nozzle Setting (In case of NO_NOZZLE_SUGGESTION)
Feeder Position (In case of fixed feeder)
Un-used Head (In case of 112)
Failed to distribute feeder.
No place to fix the component.
Component 150
Check Point: Fix the position of the component.
Failed to copy PCB data.
NOZZLE SET INFORMATION ERROR
The selected nozzle cannot be fixed to this head.
COMMAND ERROR
[A2 NOZZLE SETTING] is available only in the case that
you select EDITING for NZL.CONDITION SEL.
But you can change to EDITING temporarily. (while you
don't exit from making data mode) If you want to change,
push the [ENTER] key. If you don't want to change, push
any other key.
No head available to handle the component.
Component 150
Check Point:
Component Size
Required Nozzle(Component data)
Wait a moment while
copying PCB data....
Nozzle settings are shown below.
XY TABLE[Upper = Head No., Lower = Nozzle Type]
Head 1 2 3 4 5 6 7 8
Nzl. 1 1 1 2 2 2 2 2
Nozzle settings are shown below.
Machine 2
XY TABLE[Upper = Head No., Lower = Nozzle Type]
Head 1 2 3 4 5 6 7 8
Nzl. 1 1 1 2 2 2 2 2
There is no more than two mount data.
In this condition, this function is not available. You can not
select "REPLACE" or "MULTIPLY COMPONENT" when
Component data is not available.
(meaning)The number of PCBs you are trying to select as fixed
PCBs for data creation exceeds the allowable number
(cause)An attempt was made to register five or more PCBs as fixed
PCBs.
(remedy)Select one of the PCBs already registered as a fixed PCB
and cancel it.
(meaning)An attempt was made to pick up components without an
appropriate nozzle. |
(cause)The setting in the component data for the nozzles to be used
is wrong.
(remedy)Go back to the editing screen and check the component
data.
(meaning)There is no head to which a nozzle which can be used to
pick up the components can be attached.
(cause)If the setting for the recommended nozzle is set to "None",
the nozzles has already been decided by the user, and there is no
empty space; or a fixed feeder is being used, and the appropriate
nozzles cannot be attached to a head which will reach that feeder.
Also, it may be that a head has been installed which cannot move
into the work area, so the nozzle cannot be attached to it.
(remedy)Go back to the editing screen and change the nozzle posi-
tion or the feeder position.
(meaning)An error occurred in the feeder layout when creating the
data.
(cause)Because the data is too complex, ultimately there are no
more places where feeders can be attached. Or there are too many
feeders, so that the layout is logistically impossible
(remedy)Try fixing the setting position for the component where the
problem is occurring, or shift that component to another machine.
(meaning)An error occurred in copying the PCB data.
(cause) There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. In any other case, check to see how
often the problem occurs, and contact the manufacturer.
(meaning)When the nozzle configuration was edited, a setting was
used which attaches a nozzle to a head which can not accommo-
date that nozzle.
(cause)Same as above.
(remedy)Do not attach that nozzle to that head.
(meaning)The nozzle setting is possible only when the nozzle set-
ting conditions are edited manually.
(cause)The nozzle setting was selected even though the nozzle
setting conditions must be edited manually.
(remedy)Do not change that setting, or edit the setting conditions
manually.
(meaning)No head exists which can be used with the components.
(cause)Because the components are too big, there is no head to
which an appropriate nozzle can be attached, or there is something
wrong with the component data setting specifying the nozzle to be
used.
(remedy)Go back to the editing screen and check the component
data.
(meaning)PCB data is being copied. This is not an error message.
(cause)None
(remedy)Please wait until the data has been copied.
(meaning)The bulk substitution and component separation functions
cannot be used because there is no data in the placing information.
(cause)No placing information exists.
(remedy)Input the placing data.

Ea -15
ERROR MESSAGES LIST
Ea
Ea00691
Ea00692
Ea00693
Ea00700
Ea00701
Ea00702
Ea00703
Ea00704
Ea00705
Ea00706
Ea00707
Ea00710
There is no more than two componet data.
In this condition, this function is not available. You can not
select "REPLACE" or "MULTIPLY COMPONENT" when
Component data is not available.
There is no more than two mount or component data.
In this condition, this function is not available. You can not
select "RENUMBER COMPONENT" tavailable. when
Component data or Mount data is not available.
Not find new Component number All component number
used
Failed to open component information.
Failed to read component information.
Failed to write component information.
Component information are not selected.
There are components on destination whose name is
same as the one shown below. Would you continue?
Component 3
Component Name R3216
[ESC] key to abort
Other key to continue
The component shown below can not be moved because
it doesn't fulfill the condition.
Component 3
Component Name R3216
The condition for moving component
Not using fixed component reference function
Using feeder optimization
The component shown below uses "Teaching" for "Feeder
Position". Would you continue?
Component 3
Component Name R3216
[ESC] key to abort
Other key to continue
The component is multipled.
Would you define as the alternate component?
[ESC] key is not.
Other key is defined.
Failed to open PCB data.
Machine 2
PCB CUK93001
(meaning)The bulk substitution and component separation func-
tions cannot be used because there is no component data.
(cause)No component information exists.
(remedy)Input the component information.
(meaning)The component number control function cannot be used
because there is no data in the component or placing information.
(cause)There is no component or placing information.
(remedy)Input the component or placing information.
(meaning)Editing is not possible because there is not enough space
available for the remaining component data that has to be regis-
tered.
(cause)There is too much component data registered which is not
needed, or there is too much component data which is actually
being used.
(remedy)If too much unnecessary data has been registered, de-
lete some of it. In any other case, the supplementary editing func-
tion cannot be used.
(meaning)An error occurred in the component in formation file.
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. In any other case, check to see how
often the problem occurs, and contact the manufacturer.
(meaning)An error occurred in the component in formation file.
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. In any other case, check to see how
often the problem occurs, and contact the manufacturer.
(meaning)An error occurred in the component in formation file.
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. In any other case, check to see how
often the problem occurs, and contact the manufacturer.
(meaning)Component information has not been selected.
(cause)Same as above.
(remedy)Select the component information.
(meaning)When components are being moved in the component
information, a component with the same name already exists at
the destination location.
(cause)A component with the same name is already located at that
destination.
(remedy)If having two components with the same name at the des-
tination is not a problem, go ahead with the shift. Otherwise, press
the ESC key to interrupt the shift.
(meaning)In the group of comp. being moved in the component
information screen, a component exists which uses fixed compo-
nent reference function. The component will not be moved.
(cause)Same as above.
(remedy)No remedy.
(meaning)In the group of components being moved on the compo-
nent information screen, feeder position coordinates exist which
are teaching data.
(cause)Same as above.
(remedy)To cancel the movement because of the position coordi-
nate teaching, press the ESC key. To continue the movement press
any other key.
(meaning)When you execute the multiply component, you select
whether using alternate component or not. This component is al-
ready alternated, this function is not used.
(cause)
(remedy)
(meaning)An error occurred when opening the PCB file.
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. In any other case, check to see how
often the problem occurs, and contact the manufacturer.
Ea00711
Ea00712
Ea00713
Ea00715
Ea00720
Ea00721
Ea00722
Ea00723
Ea00724
Ea00725
Ea00726
Failed to read PCB data.
Machine 2
PCB CUK93001
Failed to write PCB data.
Machine 2
PCB CUK93001
Failed to copy PCB data.
Machine 2
PCB CUK93001
Failed to fix the component in PCB.
Machine 2PCB CUK93001
Fixed component information error to open fixed compo-
nent information.
Fixed component information error
Failed to read fixed component information.
Fixed component information error
Failed to write fixed component information.
Fixed component information error
Failed to write fixed component information.
Fixed component information error
Specified fixed component doesn’t exist.
Fixed component information error
“Component Name” are different between PCB data and
fixed component.
Fixed component information error
“Feeder Type” are different between PCB data and fixed
component.
You can’t multiply such a component as
•Using fixed component reference function
•Not using feeder optimization
•Tray components
(meaning)An error occurred when opening the PCB file.
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. In any other case, check to see how
often the problem occurs, and contact the manufacturer.
(meaning)An error occurred when opening the PCB file.
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. In any other case, check to see how
often the problem occurs, and contact the manufacturer.
(meaning)An error occurred when opening the PCB file.
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. In any other case, check to see how
often the problem occurs, and contact the manufacturer.
(meaning)Fixed components in the PCB data cannot be fixed.
(cause)The components cannot be fixed because they interfere with
another feeder which has already been fixed.
(remedy)Do not attempt to fix the components causing the interfer-
ence, or stop trying to fix the components which are currently dis-
played.
(meaning)An error occurred when opening the fixed component in-
formation file.
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. If there is a problem with the disk,
check to see how often the problem occurs, and contact the manu-
facturer.
(meaning)An error occurred when opening the fixed component in-
formation file.
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. If there is a problem with the disk,
check to see how often the problem occurs, and contact the manu-
facturer.
(meaning)An error occurred when opening the fixed component in-
formation file.
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. If there is a problem with the disk,
check to see how often the problem occurs, and contact the manu-
facturer.
(meaning)The specified fixed component information does not ex-
ist.
(cause)There was an error in registering the fixed component refer-
ence number, or the fixed component has not yet been registered.
(remedy)Go back to the editing screen and check the reference
number for the fixed component. If the fixed component has not yet
been registered register it.
(meaning)The component name registered in the PCB data is dif-
ferent from the fixed component being referenced by that compo-
nent.
(cause)Same as above.
(remedy)Change the component name in the PCB data to match
that of the fixed component.
(meaning)The name of the feeder being used in the PCB data is
different from the fixed component feeder being referenced by that
component.
(cause)Same as above.
(remedy)Change the name of the feeder being used in the PCB
data to match that of the fixed component feeder.
(meaning)An attempt was made to input multiple components ref-
erencing fixed components on the component information screen.
(cause)Same as above.
(remedy)There cannot be more than one component referencing
any particular fixed component.

Ea -16
ERROR MESSAGES LIST
Ea
YV88Xabcabcabc
Ea00727
Ea00730
Ea00731
Ea00732
Ea00733
Ea00734
Ea00735
Ea00736
Ea00737
Ea00738
Ea00739
Failed to fix the component in fixed component.
Alternative component error
Failed to read alternative component.
Alternative component error
Loop is not perfect.
Alternative component error
Alternative component specified in the data doesn't ex-
ist.
Machine YV112
Component 3
Alternative component error
"Feeder Type" is not same as original one.
In Static Components, the component data of same name
are dealed with the alternative component. Each alter-
native components need to same the above condition.
Alternative component error
"Required Nozzle" is not same as original one.
In Static Components, the component data of same name
are dealed with the alternative component. Each alter-
native components need to same the above condition.
Alternative component error
"CountOutStop" is not same as original one.
In Static Components,the component data of same name
are dealed with the alternative component. Each alter-
native components need to same the above condition.
Alternative component error
"UpdateGroupNo" must be all positive or all 0 in loop.
In Static Components,the component data of same name
are dealed with the alternative component. Each alter-
native components need to same the above condition.
Alternative component error
Mount table is not same as original one.
Alternative component error
You can't use alternative function for tray.
Alternative component error
"Component Name" are different from original one.
(meaning)Components registered in the fixed components cannot
be fixed.
(cause)The components cannot be fixed because they interfere with
another feeder which has already been fixed.
(remedy)Edit the fixed component information and delete the com-
ponent which is causing the interference.
(meaning)An error occurred when reading the alternative compo-
nent data.
(cause)The data for the alternative component specified by the
component data does not exist, or there is a problem with the hard
disk.
(remedy)Go back to the editing screen, and if the alternative com-
ponent does not exist, register it, or change the number of the al-
ternative component.If there is a problem with the hard disk, check
to see how often it occurs, and contact the manufacturer.
(meaning)The settings for alternative components must form a loop
that goes from 1 to 2 to 3 and back to 1 again, but they do not form
this loop.
(cause)The alternative component settings go from 1 to 2 to 3 and
then stop, or form a figure 6 by going from 1 to 2 to 3 and back to 2
again.
(remedy)Go back to the editing screen and check the alternative
component numbers.
(meaning)There is no alternative component data.
(cause)The user has forgotten to register the alternative compo-
nents, or there is a registration error in the alternative component
number.
(remedy)Go back to the editing screen and register the alternative
components, or change the number of the alternative components.
(meaning)The feeder being used for alternative components is not
the same feeder that was used for the original components.
(cause)Same as above.
(remedy)The feeder being used for alternative components must
match the feeder that was used for the original components.
(meaning)The nozzle being used for alternative components is not
the same nozzle that was used for the original components.
(cause)Same as above.
(remedy)Go back to the editing screen and make the nozzle being
used for alternative components match the nozzle that was used
for the original components.
(meaning)The setting for the "count out stop" function used with
alternative components does not match that used with the original
components.
(cause)Same as above.
(remedy)The setting for the "count out stop" function used with al-
ternative components must match that used with the original com-
ponents.
(meaning)In the alternative components loop, all of the settings for
"Use" or "Don't Use" must be set to the same setting.
(cause)In the alternative components loop, some of the compo-
nents reference fixed components, while some do not.
(remedy)Go back to the editing screen and change the settings so
that they all reference fixed components, or none of them do.
(meaning)In the alternative components loop, there are components
with different mounting tables.
(cause)When the settings for the alternative components are 1 -->
2 --> 3, No. 3 is attached to Table B although Nos. 1 and 2 are
attached to Table A, or a different combination of the above.
(remedy)Go back to the editing screen and change the feeder set-
ting numbers so that all of the alternative components are assigned
to the same mounting table.
(meaning)The alternative components cannot be used as tray com-
ponents.
(cause)An attempt was made to use alternative components as
tray components.
(remedy)Go back to the editing screen and change the alternative
component number for the tray components to 0.
(meaning)The name of the alternative component does not match
the name of the original component.
(cause)Same as above.
(remedy)Go back to the editing screen and change the name of
the alternative component so it matches that of the original compo-
nent.
Ea00740
Ea00741
Ea00742
Ea00750
Ea00751
Ea00752
Ea00760
Ea00761
Ea00762
Ea00763
Ea00764
Failed to open fixed component matching work file.
Failed to read fixed component matching work file.
Failed to write fixed component matching work file.
Failed to open fixed component work file.
Failed to read fixed component work file.
Failed to write fixed component work file.
You can't multiply component so many times.
Mount data specifies too big component number.
Selected PCB is not registered in selected line.
Too much point, local and 4-point fiducial data.
Too much mark data.
(meaning)An error occurred in opening the work file for the fixed
component matching
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. If there is a problem with the disk,
check to see how often the problem occurs, and contact the manu-
facturer.
(meaning)An error occurred in opening the work file for the fixed
component matching
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. If there is a problem with the disk,
check to see how often the problem occurs, and contact the manu-
facturer.
(meaning)An error occurred in opening the work file for the fixed
component matching
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. If there is a problem with the disk,
check to see how often the problem occurs, and contact the manu-
facturer.
(meaning)An error occurred in opening the work file for the fixed
component matching
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. If there is a problem with the disk,
check to see how often the problem occurs, and contact the manu-
facturer.
(meaning)An error occurred in opening the work file for the fixed
component matching
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. If there is a problem with the disk,
check to see how often the problem occurs, and contact the manu-
facturer.
(meaning)An error occurred in opening the work file for the fixed
component matching
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB dat
a and then delete it. If there is a problem with the disk, check
to see how often the problem occurs, and contact the manufacturer.
(meaning)When component separation is done on the component
information screen, the number of component divisions exceeds
the upper limit.
(cause)An excessively large value was input for the number of com-
ponent divisions
(remedy)Reduce the number of component divisions.
(meaning)The component number specified in the mounting data
exceeds the maximum number of components that the machine
can accommodate.
(cause)The number input for the components in the mounting data
is too large.
(remedy)Go back to the editing screen and correct the component
number in the mounting data.
(remedy)Go back to the editing screen and correct the component
number in the mounting data.
(meaning)The selected PCB data has not been registered on the
selected line.
(cause)There is an error in the selection of either the line or the
PCB data, or the PCB data has not been registered.
(remedy)Correct the selection of either the line or the PCB data, or
register the PCB data
(meaning)There are too many elements of point, local or 4-point
fiducial data.
(cause)Too many point, local or 4-point fiducials are being used.
(remedy)Reduce the number of point, local or 4-point fiducials.
(meaning)There are too many elements of mark data.
(cause)There are too many elements of mark data being used for
fiducials and bad marks.
(remedy)Reduce the mark data.