Ea - 25 ERROR MESSAGES LIST Ea Ea02150 Ea02151 Ea02152 Ea02153 Ea02154 Ea02155 Ea02156 Ea02157 Ea02158 Ea02159 Ea02160 Ea02161 Ea02170 Ea02171 Ea02172 Ea02173 Ea02174 Ea02175 Ea02176 Ea02177 Ea02200 Ea02201 Ea02210 Ea022…

Ea -24
ERROR MESSAGES LIST
Ea
Ea01506
Ea01507
Ea01508
Ea01509
Ea01510
Ea01600
Ea01601
Ea01602
Ea01603
Ea01604
Ea01605
Ea01606
Ea01607
PCB DATA ERROR
There is no pcb name in communication data.
Or specified name is different from a name in the data.
DATA CONVERSION ERROR
The data could not be converted to the communication
format.
To send/receive PRODUCTION HISTORY, PCB data
should be already defined at receiving side.
SWITCH PCB ERROR
It cannot switch pcb data in machine by "@SWI" online
command.
CMU ERROR
Comunication error happens.
Please change communication line to next machine.
NAME: SM112_NO1
TYPE: VIOS
CMU PORT: COM1
If all OK, press [ENTER] key to continue.
AUTO DISTRIBUTION ERROR
Failed to open auto distribution information.
Machine YV112
AUTO DISTRIBUTION ERROR
Failed to read auto distribution information.
Machine YV112
(1)Check the alternate component.
AUTO DISTRIBUTION ERROR
Failed to write auto distribution information.
Machine YV112
AUTO DISTRIBUTION ERROR
No machine can handle the component shown below.
Machine YV112
Component 3
Check the component. (Tray Information, Alignment type,
Nozzle Type, Mount Position, Dump Way)
AUTO DISTRIBUTION MESSAGE
The pickup position of the component shown below is
TEACHING. Is this movable?Machine YV112
Component 3
Component Name R3216
[ESC] key to abort
Other key to continue
AUTO DISTRIBUTION ERROR
Aborted by command.
AUTO DISTRIBUTION MESSAGE
The number of mount and component data of the ma-
chine is so many that it may cause PCB data error.
Machine YV112
Auto distribution will be continued.
AUTO DISTRIBUTION MESSAGE
The component shown below is stick component. Teach
the pickup position of the component and set "No" for
"Use feeder opt." of the component data.
Machine YV112
Component 3
Component Name SOP16
(meaning)There is an error in the data being sent or received.
(cause) There is no PCB name in the data being sent or received;
or the specified PCB name is different from the one in the file.
(remedy) With VIOS data, update the file table With UFOS data,
make sure the file name and the PCB name specified in the file are
the same.
(meaning) Error occurred in converting data to ASCII file for com-
munication.
(cause) Data file being converted has possibly been destroyed.
(remedy) Recover data.
(meaning) The PCB being produced on the machine could not be
switched using online commands.
(cause) The machine is in the automatic operation mode.
(remedy) Stop the machine and reset it. Then use online commands
to switch the PCB being produced.
(meaning)Data communication was not possible.
(cause)There is a problem with the communications circuit.
(remedy)Check the communications function of the personal com-
puter that contains the communications circuit.
(meaning)Reconnect the communications cable to the machine
which will be used for the communications.
(cause)If the option settings for the YVOS2 indicate that the switch-
ing to the target machine is to be done manually this message
indicates that the switching should be done at this point.
(remedy) If it is not necessary to connect the communications cable,
set the YVOS2 option settings so that the communications circuit
is switched automatically.
(meaning) Failed to open the file for line data distribution.
(cause) Capacity shortage or defect of HDD.
(remedy) Move seldom-used PCB data to floppy to increase HDD
capacity. If the problem still happens, Contact the manufacturer.
(meaning) Failed to read the file for line data distribution.
(cause) Defect of HDD. Alternate component is used.
(remedy) Contact the manufacturer. Not use the alternate compo-
nent.
(meaning)Failed to write the file for line data distribution.
(cause) Capacity shortage or defect of HDD.
(remedy) Move seldom-used PCB data to floppy to increase HDD
capacity. If the problem still happens, Contact the manufacturer.
(meaning) No machine can handle the component.
(cause)In the case of tray component, the lack of tray changer can
cause this. Or Required Nozzle, mount position, AlignmentModule
setting can cause this.
(remedy) Remove those causes described above.
(meaning) The pickup position of the component is TEACHING.
Can the AUTO DISTRIBUTION move it?
(cause) The setting of "Use feeder opt." Of this component is "Yes"
although its position is TEACHING.
(remedy) If it is unmovable, press [Esc] key to abort and set "No"
for "Use feeder opt". Or press other key to continue.
(meaning) AUTO DISTRIBUTION was aborted by user's command.
Not an error message.
(cause)
(remedy)
(meaning)The number of mount and component data is so many
that it may cause data error in running mode.
(cause) Same as meaning.
(remedy) You had better move some data in 2/DATA/M 2/
DATA_GENERATOR A3 COMPONENT INF. But it can be OK even
if you don't modify data.
(meaning) You must teach the pickup position of the stick compo-
nent and set "No" for "Use feeder opt." in component data.
(cause) The setting of "Use feeder opt." Of the component is "Yes"
although it is stick component.
(remedy) Teach the pickup position at the machine and set "No" for
"Use feeder opt.".
Ea01617
Ea01620
Ea01760
Ea01761
Ea01770
Ea01771
Ea01780
Ea01781
Ea01790
Ea01791
Ea01900
Ea01903
Ea02000
Ea02001
Ea02002
Ea02003
Ea02004
Ea02005
Ea02006
Ea02100
AUTO DISTRIBUTION MESSAGE
The number of the feeder is so many that it may cause
some error.
Feeder group Pneumatic type
Feeder type 8mmTape
Auto distribution will be continued.
AUTO DISTRIBUTION ERROR
No machine can handle the component shown below.
Component 3
Check the feeder number of line.
FIXED COMPONENT BIT ERROR
Failed to read fixed component bit information.
Machine YV112
FIXED COMPONENT BIT ERROR
Failed to write fixed component bit information.
Machine YV112
FIXED COMPONENT MASK ERROR
Failed to read fixed component mask information.
FIXED COMPONENT MASK ERROR
Failed to write fixed component mask information.
Will you try cycle time estimation?
[ESC] : No
Others: Yes
Will you try line data distribution?
[ESC] : No
Others: Yes
Alternative component error
"Alignment Type" is not same as original one.
In Static Components, the component data of same name
are dealed with the alternative component.
Each alternative components need to same the above
condition.
Alternative component error
"Mount Action" is not same as original one.
In Static Components, the component data of same name
are dealed with the alternative component.
Each alternative components need to same the above
condition.
Could not receive start of code(@).
The machine can not respond to this command.
One of the following could cause this error:
- The machine is not in RUNNING mode.
- The machine is not under RESET condition.
Please recover and try again.
FILE TABLE ERROR
Failed to open the "file table" file.
FILE TABLE ERROR
Failed to read the "file table" file.
FILE TABLE ERROR
Failed to write the "file table" file.
FILE TABLE ERROR
Failed to seek the "file table" file.
FILE TABLE ERROR
The PCB number is out of limit.
FILE TABLE ERROR
The number of the record in "file table" file exceeds. limit.
FILE TABLE ERROR
Tried to write the record beyond the "file table" file end.
VIOS ->UFOS conversion error
The HYPER cannot use feeder type in this data. The fol-
lowing, the HYPER cannnot use feeder type.
BULK feeder
Tape A - D
etc.
(meaning) The number of the displayed feeder is so many that it
exceeds your possession and may cause some error.
(cause) Same as meaning.
(remedy) You had better move some data in 2/DATA/M 2/
DATA_GENERATOR
A3 COMPONENT INF. But it can be OK even if you don't modify
data.
(meaning) No machine can handle this components.
(cause) The number of feeder is lucked in line, so this component
can not move each machines.
(remedy) Remove those causes described above.
(meaning) Failed to read the file for fixed component bit.
(cause) Defect of HDD.
(remedy) Contact the manufacturer.
(meaning) Failed to write the file for fixed component bit.
(cause) Defect of HDD.
(remedy) Contact the manufacturer.
(meaning)Failed to read the file for fixed component mask.
(cause)Defect of HDD.
(remedy)Contact the manufacturer.
(meaning)Failed to write the file for fixed component mask.
(cause) Defect of HDD.
(remedy) Contact the manufacturer.
(meaning)Will you try cycletime estimation following to data gen-
eration. This is not an error.
(cause)
(remedy)
(meaning) Will you try data generation following to cycletime esti-
mation. This is not an error.
(cause)
(remedy)
(meaning) The Alignment Type used for alternative components is
not the same type that was used for the original components.
(cause) Same as above.
(remedy) The Alignment Type used for alternative components must
match the type that was used for the original components.
(meaning) The Mount Action used for alternative components is not
the same type that was used for the original components.
(cause) Same as above.
(remedy) The Mount Action used for alternative components must
match the type that was used for the original components.
No. 1900 corresponds to communication command error message.

Ea -25
ERROR MESSAGES LIST
Ea
Ea02150
Ea02151
Ea02152
Ea02153
Ea02154
Ea02155
Ea02156
Ea02157
Ea02158
Ea02159
Ea02160
Ea02161
Ea02170
Ea02171
Ea02172
Ea02173
Ea02174
Ea02175
Ea02176
Ea02177
Ea02200
Ea02201
Ea02210
Ea02211
Ea02220
TEXT -> VIOS conversion error
Mount data or machine data is not found.
TEXT -> VIOS conversion error
There is a character not data in mount data or mashine
data. ( TAB is impossible to be used, either. )
TEXT -> VIOS conversion error
Component data is not found.
TEXT -> VIOS conversion error
There is a character not data in component data. ( TAB is
impossible to be used, either. )
TEXT -> VIOS conversion error
Mark data is not found.
TEXT -> VIOS conversion error
There is a character not data in mark data. ( TAB is im-
possible to be used, either. )
TEXT -> VIOS conversion error
Pcb data or machine option or YVOS option is not found.
TEXT -> VIOS conversion error
There is a string not keyword in pcb data or machine
option or YVOS option.
TEXT -> VIOS conversion error
Production record data is not found.
TEXT -> VIOS conversion error
There is a wrong character in production record data.
TEXT -> VIOS conversion error
Error log data is not found.
TEXT -> VIOS conversion error
There is a wrong character in error log data.
VIOS -> TEXT conversion error
Mount data or machine data is not found.
VIOS -> TEXT conversion error
Component data or mark data is not found.
VIOS -> TEXT conversion error
Pcb data is not found.
VIOS -> TEXT conversion error
Machine option or YVOS option is not found.
VIOS -> TEXT conversion error
Production record data is not found.
VIOS -> TEXT conversion error Error log data is not found.
TEXT <-> VIOS conversion error
Not exist the destination directory. Now, May I make the
directory?
[Enter]: Yes
[Esc] : No
TEXT <-> VIOS conversion error
Not exist the destination directory. Cannot convert.
PCB TRANSFER ERROR
The PCB detected before transfer is not detected after
transfer. Maybe there is a PCB on the conveyor. Set the
PCB to its normal position manually.
Befere transfer for A table ***
After transfer on A table ***
Before transfer for B table ***
After transfer on B table ***
PCB TRANSFER ERROR
Unexpected PCB is on the conveyor. On the auto-run-
ning or the transfer, two pcbs are detected at the same
time.
A) At the entrance and the waiting position.
B) At the waiting position and the mounting position.
C) At the mounting position and the exit.
Error Detail No. ***
Controlling vision image
Please select control by arrow key, and hit [Enter] key. If
hitting [ESC] key, it finishes.
Controlling vision image
The controlling was canceled. Hit any key, please.
Saving vision image
Cannot save more. Too many files is stored. If saving,
delete unnessesary files.
Ea02221
Ea02222
Ea02223
Ea02224
Ea02225
Ea02226
Ea02227
Ea02228
Ea02229
Ea02230
Ea02231
Ea02232
Ea02240
E2241
E2242
E2243
Ea02244
Ea02245
Ea02246
Saving vision image: sel.tbl.num
Please select saving table number by [Ins.] or [Del.] key,
and hit [Enter] key. If hitting [ESC] key, it finishes.
Saving vision image: sel.hed.num
Please select saving head number by [Ins.] or [Del.] key,
and hit [Enter] key. If hitting [ESC] key, it finishes.
Saving vision image: sel.cam.num
Please select saving camera number by [Ins.] or [Del.]
key, and hit [Enter] key. If hitting [ESC] key, it finishes.
Saving vision image: selecting file form
Please select saving file form by arrow key, and hit [En-
ter] key. If hitting [ESC] key, it finishes.
Saving vision image: inputting file name
Please input saving file name, and hit [Enter] key. Don’t
input ext., please. If hitting [ESC] key, it finishes.
Saving vision image
The following file already exists. May I rewrite?
[Enter] : Yes
[ESC] : No (Finish)
Saving vision image
Saving now. Just a moment, please.
Saving vision image
Successfully saved. The following file was made in cur-
rent dir. Hit any key, please.
Saving vision image
Unsuccessfully saved. The file was not made. Hit any
key, please.
Saving vision image
Failed to open the file. The cause may be which the fol-
lowing.
• The file or HDD is destroyed.
• Too many files in the root dir.
• HDD full.
The file was not made. Hit any key, please.
Saving vision image
Failed to write data in the file.
The cause may be which the following.
• The file or HDD is destroyed.
• HDD lack.
The file was not made. Hit any key, please.
Saving vision image
Failed to get data. The cause may be which the follow-
ing. • Illegal buffer number.
• Image size is 0.
• Image size is too large.
The file was not made. Hit any key, please.
Loading vision image
No file in selected file form. It’ll finish loading. Hit any key,
please.
Loading vision image: sel.tbl.num
Please select loading table number by [Ins.] or [Del.] key,
and hit [Enter] key. If hitting [ESC] key, it finishes.
Loading vision image: sel.hed.num
Please select loading head number by [Ins.] or [Del.] key,
and hit [Enter] key. If hitting [ESC] key, it finishes.
Loading vision image: sel.cam.num
Please select loading camera number by [Ins.] or [Del.]
key, and hit [Enter] key.
If hitting [ESC] key, it finishes.
Loading vision image: selecting file form
Please select saving file form by arrow key, and hit [En-
ter] key. If hitting [ESC] key, it finishes.
Loading vision image: selecting file name
Please select saving file name by arrow key, and hit [En-
ter] key. Inputting file name is possible. If hitting [ESC]
key, it finishes.
Loading vision image
Now in selected table, head, camera stored image is
cleared. Are you ready?
[Enter] : Yes
[ESC] : No (Finish)

Ea -26
ERROR MESSAGES LIST
Ea
Ea02247
Ea02248
Ea02249
Ea02250
Ea02251
Ea02252
Ea02260
Ea02261
Ea02262
Ea02263
Ea02264
Ea02265
Ea02266
Ea02300
Ea02301
Ea02302
Ea02303
Ea02304
Ea02305
Ea02306
Ea02307
Loading vision image
Loading now. Just a moment, please.
Loading vision image
Successfully loaded. The following file was displayed. Hit
any key, please.
Loading vision image
Unsuccessfully loaded. The file was not displayed. Hit
any key, please.
Loading vision image
Failed to open the file. The cause may be which the fol-
lowing.
• The file or HDD is destroyed.
The file was not loaded. Hit any key, please.
Loading vision image
Failed to write data in the file. The cause may be which
the following.
• The file or HDD is destroyed.
The file was not loaded. Hit any key, please.
Loading vision image
Failed to get data. The cause may be which the follow-
ing. • Illegal buffer number.
• Image size is 0.
• Image size is too large.
The file was not loaded. Hit any key, please.
Deleting vision image
No file in selected file form. It’ll finish deleting. Hit any
key, please.
Deleting vision image: sel.f.form
Please select Deleting file form by arrow key, and hit [En-
ter] key. If hitting [ESC] key, it finishes.
Deleting vision image: sel.f.name
Please select deleting file name by arrow key, and hit
[Enter] key. Inputting file name is possible, too. If hitting
[ESC] key, it finishes.
Deleting vision image
The following file is deleted. Are you ready?
[Enter]: Yes
[Esc] : No
Deleting vision image
Deleting now. Just a moment, please.
Deleting vision image
The following file was deleted. Hit any key, please.
Deleting vision image
The following file was not deleted. The cause is which,
• the attrib is only reading.
• the file is destroyed.
Hit any key, please.
Not a VIOS extension
Contact your supplier.
Attempted to copy to a file having the same file name.
Machine *
PCB ********
Failed to copy PCB data.
Machine *
PCB ********
Please check the empty area in target disk. In case of
VIOS->TEXT convert, it may be not enough area in the
floppy disk.
Failed to delete PCB data.
Machine *
PCB ********
Failed to rename PCB data.
Machine *
PCB ********
Failed to make directory.
Machine *
PCB ********
Insufficient disk space.
Failed to open database file.
Ea02308
Ea02309
Ea02310
Ea02311
Ea02312
Ea02313
Ea02314
Ea02315
Ea02316
Ea02317
Ea02318
Ea02319
Ea02411
Ea02420 _
Ea02421
Ea02500
Ea02501
Ea02502
Ea02503
Ea02504
Ea02505
Ea02506
Database file does not exist.
STATIC_COMPONENTS___ data does not exist.
Machine *
PCB data does not exist.
Machine *
PCB ********
Failed to get PCB data date.
Machine *
PCB ********
Failed to set PCB data date.
Machine *
PCB ********
Failed to get PCB data size.
Machine *
PCB ********
PCB data does not exist.
Machine *
PCB ********
The PCB data is set in wrong order.
Machine *
PCB ********
Failed to open machine data.
Machine *
Failed to read machine data.
Machine *
Failed to write machine data.
Machine *
Machine data is set in wrong order.
Machine *
INTERNAL COMMUNCATION TIMEOUT ERROR
Internal communication routine was interrupted by time
out error.
Edit data loading error
Failed to load the data used editor.
The cause is which the following:
- Lack of memory.
- Failed to read the data.
- Failed to read the message.
Edit data saving error
Failed to save the data editted. The cause is which the
following:
- Lack of disk space.
- Disk or file is destroyed.
- Not exist storage of data.
INITIALIZATION ERROR
It hasn’t answerd “Servo Board”. Machine can’t be started.
Please finish application soft after error message is
cleared.
INITIALIZATION ERROR
It is short of “Servo Board”. Machine can’t be started.
Please finish application soft after error message is
cleared.
INITIALIZATION ERROR
Version of Servo-Soft is not correct. Machine can’t be
started. Please finish application soft after error message
is cleared.
VISION DATA TRANSFER ERROR
Data couldn’t be transfered in “Vision Board”.
I/O DATA TRANSFER ERROR
Vacuum Level Data couldn’t be transfered in “I/O Board”.
INITIALIZATION ERROR
It failed in the initialization of Co-Planarity unit. Machine
can’t be started. Please finish application soft after error
message is cleared.
I/O LIST DATA ERROR
No. %d
Fail to read and Init IoList Data. Machine can’t be started.
Please finish application soft after error message is
cleared.