Ea - 3 ERROR MESSAGES LIST Ea Ea00053 Ea00054 Ea00055 Ea00056 Ea00057 Ea00060 Ea00061 Ea00062 Ea00063 Ea00064 Ea00065 Ea00066 Ea00070 MARK DETECTION ERROR A part of fiducial mark is located out of the specified search ar…

Ea -2
ERROR MESSAGES LIST
Ea
Ea00028
Ea00029
Ea00030
Ea00031
Ea00032
Ea00033
Ea00034
Ea00035
Ea00036
Ea00037
Ea00038
Ea00039
COMPONENT DETECTION ERROR
Failed to detect the [Std.Chip] type component.
Mount data 765
Component data 150
Feeder set position 20
PICK UP POSITION ERROR
Failed to pick up the component at the center of the nozzle
Mount data 765
Component data 150
Feeder set position 20
ILLEGAL RESULT ERROR
The detected center position is illegal.
Mount data 765
Component data 150
Feeder set position 20
PICK UP ERROR
Failed to pick up the component. Vision system could not
find the component.
Mount data 765
Component data 150
Feeder set position 20
RETRY LIMIT OVER
Vision error: Maximum number of retries for this compo-
nent is exceeded.
Mount data 765
Component data 150
Feeder set position 20
/0000/0004/0005/0006/E
COMPONENT DETECTION ERROR
Failed to detect the component.
Mount data 765
Component data 150
Feeder set position 20
MOUNT ERROR
Failed to mount component by vacuum check
Mount data 765
Component data 150
Feeder set position 20
DUMP ERROR
Vacuum check error: Failed to dump the component.
Mount data 765
Component data 150
Feeder set position 20
VACUUM LEVEL ERROR
Vacuum level does not reach the specified level.
The component might have dropped after recognition.
Mount data 765
Component data 150
Name
Feeder set position 20
LASER SYSTEM ERROR(code 00, 03, 04, 05, 07, 08,
09, 72, 73, 74, etc)
A software or hardware error of the Laser
Alignment Unit is detected.
Mount data 765
Component data 150
Feeder set position 20
COMPONENT DETECTION ERROR(code 64, 75)
The laser sensor could not detect the component.
Please check the laser height.
Mount data 765
Component data 150
Feeder set position 20
SPEED DETECTION ERROR (code 65, 90, 91, 92, 93)
Laser system cannot read a clear image of the compo-
nent. The rotation speed is too fast.
Mount data 765
Component data 150
Feeder set position 20
(meaning)Recognition of the component was not possible.
(cause)The component has not been picked up, or the component
is too dark to be seen by the camera.
(remedy)Adjust so that the component can be picked up. Use supple-
mentary adjustment to change the recognition parameters.
(meaning)The component could not be picked up in the center of
the nozzle.
(cause)The pickup precision is poor.
(remedy)Stabilize the component pickup, or reduce the effective
diameter size of the nozzle.
(meaning)The center coordinates of the recognized component are
wrong.
(cause)The component recognition is not stable.
(remedy)Use supplementary adjustment to re-adjust.
(meaning)The vacuum sensor confirmed that a component pickup
error was made.
(cause)The component cannot be picked up, the setting for the
vacuum pressure is wrong, or the pickup conditions are not stable.
(remedy)Use supplementary adjustment to re-specify the pickup
vacuum level, or other measures to stabilize the vacuum pressure.
(meaning)The component could not be picked up successfully with
the specified number of retries.
(cause)
(remedy)Stabilize the component pickup, or the recognition param-
eters.
(meaning)An error occurred in detecting the component.
(cause)The pickup conditions are not stable, or the recognition con-
ditions are not stable.
(remedy)Use supplementary adjustment to re-adjust.
(meaning)During the vacuum check of component mounting, it was
confirmed that the component is still on the nozzle.
(cause)The volume of air discharged from the nozzle has not been
adjusted properly, or the setting for the mounting level is incorrect.
(remedy)Re-adjust the pickup level, and check the dispensing air
pressure by hand.
(meaning)The component cannot be discarded.
(cause)The dispensing air pressure is too low, or the wrong setting
has been entered for the mounting vacuum pressure.
(remedy)Adjust the data and re-adjust the dispensing pressure.
(meaning) Although there were no problems immediately prior to
image processing, it was confirmed that the vacuum pressure level
had not reached the set value.
(cause) Incorrect pickup vacuum setting, or component cannot be
picked up correctly. Component pickup position coordinates or
pickup precision may not be correct.
(remedy) Stabilize component pickup state, or readjust pickup
vacuum pressure using auxiliary adjustment.
(meaning)A problem has occurred with the laser recognition unit
hardware or software
(cause)The laser recognition unit hardware has broken down, or a
problem has occurred with the software.
(remedy)Contact the manufacturer.
(meaning) The laser beam is not reaching the component.
(cause)There is no component on the nozzle, or the setting for the
laser recognition height is inappropriate.
(remedy)Use supplementary adjustment to re-adjust the compo-
nent.
(meaning)During laser recognition, the component rotates too
quickly, causing a recognition error.
(cause)The scanning speed is too fast.
(remedy)Reduce the speed at which components are being
mounted.
Ea00040
Ea00041
Ea00042
Ea00043
Ea00044
Ea00045
Ea00046
Ea00047
Ea00048
Ea00049
Ea00050
Ea00051
Ea00052
COMPONENT DETECTION ERROR (code 66)
Minimum width of component cannot be found. The com-
ponent is round or misaligned on the nozzle.
Mount data 765
Component data 150
Feeder set position 20
COMPONENT SIZE ERROR (code 22)
Laser detection error: The measured size of the compo-
nent is out of tolerance.
Mount data 765
Component data 150
Feeder set position 20
COMPONENT POSITION ERROR(code 23)
Laser detection error: The measured position of the com-
ponent is illegal.
Mount data 765
Component data 150
Feeder set position 20
DETECTION ABORTED(code 67)
Measurement is aborted by a STOP or EMG operation.
Mount data 765
Component data 150
Feeder set position 20
LASER WINDOW ERROR(code 68, 78, 79, 80, 81, 82)
The component is too large for the window or the window
is blocked by other objects.
Mount data 765
Component data 150
Feeder set position 20
LASER COMMUNICATION ERROR(code 69)
Communication error occurred in the Laser system.
Mount data 765
Component data 150
Feeder set position 20
MEASUREMENT FAILED(code 70, 76, 77)
Too less slope detected during rotation. The image of the
component is not clear.
Mount data 765
Component data 150
Feeder set position 20
EDGE DETECTION ERROR(code 71)
Laser detection error: Too many edges detected. Part may
be incorrectly positioned.
Mount data 765
Component data 150
Feeder set position 20
CO-PLANARITY CHECK ERROR
Co-Planarity check found the lead out of Max Tweeze.
Mount data 3
Component data 11
Feeder set position 32
NOZZLE PLUGGED ERROR
Possible cause :
1. In [3/MAINTE/M]-[2/MCH_DATA]-[Vacuum Level], the
value of [Low level] of current head is too small.
2. There is component under current nozzle.
3. Current nozzle is plugged.
Please remove cause.
DETECT THE PICK ERROR BY LAM
Detected the component that was picked side of body.
Mount data 3
Component data 21
Feeder set position 11
MARK DETECTION ERROR
Failed to detect defined mark.
MARK AREA OR PERIMETER ERROR
The detected fiducial mark area or perimeter is out of
tolerance.
(meaning)The minimum width of the component cannot be detected.
(cause)An attempt has been made to use recognition on compo-
nents which are not appropriate, or the component has not been
picked up properly.
(remedy)Do not use laser recognition, or use supplementary ad-
justment to correct the component.
(meaning)The size of the component is not with in the specified
tolerance range.
(cause)The molded size of the component is inappropriate, or the
component has not been picked up correctly.
(remedy)Stabilize the pickup conditions, and check the size of the
component.
(meaning)The laser recognition results are not within the detection
range of the laser.
(cause)The component used is too big for laser recognition.
(remedy)Try using another method of recognition.
(meaning)Component recognition was interrupted before being com-
pleted.
(cause)The recognition speed is too fast, and the component on
the nozzle may have moved during recognition.
(remedy)Reduce the mounting speed.
(meaning)The component protrudes from the laser recognition win-
dow.
(cause)An attempt was made to use laser recognition with a com-
ponent for which it is not possible.
(remedy)Do not use laser recognition.
(meaning)An error occurred inside the laser recognition unit.
(cause)There may be a problem with the hardware.
(remedy)Contact the manufacturer.
(meaning)Noise has occurred in the silhouette of the component.
(cause)The light-receiving element of the laser is dirty.
(remedy)Clean the light-receiving element of the laser with alcohol.
(meaning)The edge of the component could not be detected.
(cause)The component used is not appropriate for laser recogni-
tion.
(remedy)Do not use laser recognition with this component.
Set "Co-Planarity" value larger.
Please remove cause which is shown in "Error Message".
Check the pick up position of component.
(meaning)An error occurred with fiducial mark detection.
(cause)The surface of the mark is dirty, or the data setting is wrong.
(remedy)Clean the surface of the mark with an eraser and cloth, or
use supplementary adjustment to check the data for the mark.
(meaning)The shape of the detected mark does not match the speci-
fied setting.
(cause)The shape of the mark has not been registered correctly, or
adjustment has not been done properly.
(remedy)Check the data for the mark and use supplementary ad-
justment to correct it.

Ea -3
ERROR MESSAGES LIST
Ea
Ea00053
Ea00054
Ea00055
Ea00056
Ea00057
Ea00060
Ea00061
Ea00062
Ea00063
Ea00064
Ea00065
Ea00066
Ea00070
MARK DETECTION ERROR
A part of fiducial mark is located out of the specified search
area or the fiducial correction angle is too large.
MARK SHAPE ERROR
Failed to detect a fiducial mark of the specified shape
MARK AREA OR PERIMETER ERROR
The detected fiducial mark area or perimeter is out of
tolerance (Special)
MARK DETECTION ERROR
Failed to detect defined mark.
(MarkNO. )
Do you execute VISION-CURSOR-TEACHING by
manual?
[F10] key to execute
Any other key to abort
VISION-CURSOR-TEACHING
Please teach fiducial mark while looking VISION-MONI-
TOR by manual.
[ESC] : Abort
[ENTER] : Teaching
[Arrows] : Moving at TEACH-WINDOW
[SHIFT]+[Arrows] : Moving at TEACH-WINDOW
[TAB] : Changing at TEACH-WINDOW
Failed to RESET pick routine.
Pick routine did not stop correctly.
Retrying now.
Failed to RESET component vision routine.
Component vision routine did not stop correctly. Retrying
now.
Failed to RESET fiducial routine.
Fiducial routine did not stop correctly. Retrying now.
Failed to RESET mount routine.
Mount routine did not stop correctly.
Retrying now.
Failed to RESET LASER recognition routine.
LASER recognition routine didn't finish correctly.
Ready to Retry.
LASER TIMEOUT ERROR
Laser recognition rutine was interrupted by time out er-
ror. The rutine will be reset.Please run again.
Machines has been already reset condition now.
If you want to move machine's head to DUMP POSITION,
push the [TAB] key to execute.
If not, push the other key to cancel.
PCB TRANSFER ERROR
Unexpected PCB is on the conveyor.
(meaning)The mark is not located properly within the search area.
(cause)The PCB has not been positioned correctly, or a search
area has been specified which is too small.
(remedy)Make sure the PCB is securely fastened in place, and that
the search area is appropriate.
(meaning)A fiducial mark of the specified shape cannot be detected.
(cause)The shape has not been specified correctly, or the image
which has been read is not clear.
(remedy)Check the shape information and clean the surface of the
mark.
(meaning)The shape of the detected mark does not match the speci-
fied setting.
(cause)The shape of the mark has not been registered correctly, or
adjustment has not been done properly.
(remedy)Check the data for the mark and use supplementary ad-
justment to correct it.
(meaning) Error occurred in fiducial mark detection.
(cause) Mark surface is dirty, or data setting is incorrect.
(remedy) Clean mark surface with eraser or cloth, or use auxiliary
adjustment to check mark data. Alternatively, press [F10] key and
specify mark position directly.
(Meaning) This screen is displayed while vision cursor teaching is
in progress.
(meaning)An error occurred during the pickup operation.
(cause)The sensor is defective, or the solenoid valve is not operat-
ing correctly.
(remedy)Check the operation of the head and the value set for the
sensor reaction.
(meaning)An error occurred during recognition of the component.
(cause)Communication with the vision board could not be com-
pleted normally.
(remedy)Check to see how often the problem occurs, and contact
the manufacturer.
(meaning)Recognition of the fiducial mark could not be completed.
(cause)There is a problem with communication with the vision board.
(remedy)Check to see how often the problem occurs, and contact
the manufacturer.
(meaning)Mounting could not be completed.
(cause)The sensor is defective, or the solenoid valve is defective.
(remedy)Check the operation of the solenoid valve and sensor.
(meaning)Laser recognition could not be completed.
(cause)Communication with the laser recognition unit is not being
carried out properly.
(remedy)Replace the laser recognition unit, the laser recognition
board, or the I/O board. If the problem occurs frequently, contact
the manufacturer.
(meaning)Laser recognition could not be completed.
(cause)Communication with the laser recognition unit is not being
carried out properly.
(remedy)Replace the laser recognition unit, the laser recognition
board, or the I/O board. If the problem occurs frequently, contact
the manufacturer.
Machine is already reset condition. In case head is on the feeder or
manual tray feeder, so you want to move dumping position. Press
[TAB] key.
(meaning)The number of PCBs transported on the conveyor ex-
ceeds the rated number.
(cause)PCBs are being loaded although no PCB request signal
has been issued, or an irregular PCB has been detected.
(remedy)Adjust the position of the sensor at the exit end of the
loading conveyor, or the loading sensor on this machine or re-ad-
just the PCB detection sensor and the entrance stopper sensor.
Ea00071
Ea00072
Ea00073
Ea00074
Ea00075
Ea00076
Ea00077
Ea00078
Ea00079
Ea00080
Ea00081
Ea00082
PCB TRANSFER ERROR
The PCB detected before transfer is not detected after
transfer. Maybe there is the PCB on the edge of the mov-
ing conveyor. Set the PCB to its normal position manu-
ally.
Machine is unable to start running because the conveyor
width is not ready, The conveyor width will be changed
first. Misalignment of PUSH_UP PINS or PCB on con-
veyor may damage machine.
Assure safety and push the [ENTER] key.
PCB TRANSFER ERROR
PCB is detected on the edge of the moving conveyor. Set
the PCB to its normal position manually.
PCB FIXING ERROR
PCB trans-unit, locate-pin or push-up-unit does not re-
sponse to command.
DUMP STATION FULL
Dump station is filled with components. Please remove
the components manually from the dump station, then
start again.
COMPONENT COUNT STOP
Component counter reached to specified number. Fill the
components and run again.Component data
151
Feeder set position 21
Component data 152
Feeder set position 22
COMPONENT COUNT STOP
Component counter reached to specified number. Fill the
components and run again.
Component data 150
PCB TRANSFER ERROR
When the PCB was transferred to fixed conveyer of PCB
exit side, error happened for time over. Maybe the PCB
stopped between fixed conveyor and moving conveyor.
Or the PCB stopped in fixed conveyor of PCB exit side.
Set the PCB to its normal position manually.
PCB TRANSFER ERROR
The PCB was not able to exit from fixed conveyer of PCB
exit side. Maybe the PCB stopped on edge of fixed con-
veyer of PCB exit side. Set the PCB to its normal position
manually.
PCB TRANSFER ERROR
Moving conveyor can not move, because there is the PCB
on the edge of the moving conveyor. Set the PCB to its
normal position manually.
PCB TRANSFER ERROR
Fixed conveyor of PCB entrance side stopped for time
over. Check whether the PCB stops in fixed conveyor of
PCB entrance side.
PCB TRANSFER ERROR
PCBs are found both on entrance and entrance stopper.
Check whether more than 1 pcbs are conveyed to the
working position.
(meaning)The PCB which was detected prior to the beginning of
loading could not b confirmed after being loaded; a PCB which was
confirmed before unloading cannot be detected at the exit; or a PCB
which could not be confirmed before loading or unloading was con-
firmed after being loaded or unloaded.
(cause)
(remedy)Re-adjust the PCB detection sensor. If PCBs are not be-
ing transported correctly, adjust the conveyor unit and other related
parts, or adjust the PCB width data.
(meaning)This is a warning message which appears when the con-
veyor width is changed.
(cause)None
(remedy)Press any key.
(meaning)A PCB was detected by the danger alert sensor at the
connecting section of the moving conveyor.
(cause)This is to alert the operator that a PCB may be left on the
conveyor at the connecting section.
(remedy)If there is a PCB at the connecting section, remove it. If
there is none, the sensor may be malfunctioning. Use an I/O moni-
tor to check the sensor operation.
(meaning)The locating pin sensor or the pushup sensor on the PCB
transport unit does not respond correctly to the status of the sole-
noid.
(cause)The sensor position has not been adjusted correctly, or op-
eration is unstable because the speed controller has been tight-
ened too far.
(remedy)Check the operation of height-related sensors on the PCB
transport unit.
(meaning)The dump station is filled with discarded components.
(cause)The overflow sensor at the dump station has been activated.
(remedy)Remove all of the components discarded at the dump sta-
tion.
(meaning)During a test run, errors are still occurring after the speci-
fied number of test runs.
(cause)Pickup confirmation or another operation is unstable.
(remedy)Check the pickup operation, and use supplementary ad-
justment to check the status of recognition.
(meaning)During a test run, errors are still occurring after the speci-
fied number of test runs.
(cause)Pickup confirmation or another operation is unstable.
(remedy)Check the pickup operation, and use supplementary ad-
justment to check the status of recognition.
(meaning)When a PCB is being unloaded from the conveyor, the
PCB does not arrive at the exit sensor.
(cause) There are still PCBs left on the conveyor, or the conveyor
exit sensor was unable to detect the PCB.
(remedy)Adjust the conveyor and check that PCBs are being car-
ried smoothly to the exit. Also check the operation of the conveyor
exit sensor.
(meaning)A PCB could not be unloaded to the next process.
(cause)The conveyor exit sensor is continuing to detect a PCB.
(remedy)Adjust the conveyor exit sensor, or adjust the conveyor so
that PCBs arriving at the exit can be transported smoothly to the
next process.
(meaning)A PCB exists between Table A and Table B, preventing
the tables from being moved.
(cause)There is a PCB between Table A and Table B.
(remedy)Remove the PCB and adjust the conveyor so it moves
smoothly from Table A to Table B; or adjust the sensor at the con-
necting section of the conveyor.
(meaning)A PCB has been loaded with no problem but is not car-
ried as far as the standby position sensor.
(cause)The standby position sensor or the conveyor entrance sen-
sor is defective or the PCB has stopped somewhere along the en-
trance conveyor.
(remedy)Adjust the conveyor so that PCBs are carried smoothly.
Check the operation of the entrance sensor and the PCB standby
position sensor.
(meaning)PCBs are found both on entrance and entrance stopper.
(cause)More than 1 pcbs may be conveyed to the working position.
(remedy)Remove the PCB which is detected by entrance sensor.

Ea -4
ERROR MESSAGES LIST
Ea
Ea00091
Ea00092
Ea00093
Ea00094
Ea00095
Ea00100
Ea00101
Ea00102
Ea00103
CO-PLANARITY CHECK LEAD DETECT ERROR
A reflective object was detected at the start position of
scanning. Please check Body Size in Component Info.
Mount data
Component data
Feeder set position
CO-PLANARITY CHECK LEAD DETECT ERROR
Failed to detect the end of edge on the last lead.
Please check Body Size in Component Info.
Mount data
Component data
Feeder set position
CO-PLANARITY CHECK LEAD NUMBER ERROR
Failed to detect the specified number of leads.
Mount data
Component data
Feeder set position
CO-PLANARITY CHECK LEAD GAP ERROR
The gap between the adjacent leads is out of the thresh-
old.
Mount data
Component data
Feeder set position
CO-PLANARITY CHECK LEAD CO-PLANARUTY ER-
ROR
Co-planarity level is out of the threshold.
Mount data
Component data
Feeder set position
EMERGENCY STOPPING FUNCTION
for safety is now active. Confirm Safety and push the
SERVO ON SWITCH to enable the machine. If you suc-
ceed, the RED-MESSAGE-LIGHT will be switched off.
Please make sure that the EMERGENCY STOP is ON.
When you wish to turn off the power, you have to make
sure that the EMERGENCY STOP is ON.
SEARCH FOR ORIGIN is not performed yet. Select
SEARCH ORIGIN first by using the COMMAND LISTS.
Ready to turn off Power.
A) System can be switched off now, or
B) Push any key to enter SLEEP mode.
Unsaved data in memory will be lost when the system is
switched off without this message being displayed.
(Meaning)Co-planarity checking function inspect a component along
to the rectangle shape which include the component size as its
inside, and it should not detect leads at the corner position of that
rectangle. Because co-planarity checking start and finish scanning
always at the corner position of that rectangle, if a lead is detected
at the start position or finish position, this error message appears
to inform the problem.
(Cause)qThe size definition of the component is wrong.wSome ob-
stacle so as bumper is at the corner position and had been
detected.eBecause some shape information so as number of leads
is not correct, and the camera recognition had reported wrong com-
ponent position on the pipet.
(Remedy)qCorrect size info..wIf the component is in the specifica-
tion, adjust the Co-Pl level in component info.eCorrect the shape
data.
(Meaning)Co-planarity checking function inspect a component along
to the rectangle shape which include the component size as its
inside, and it should not detect leads at the corner position of that
rectangle. Because co-planarity checking start and finish scanning
always at the corner position of that rectangle, if a lead is detected
at the start position or finish position, this error message appears
to inform the problem.
(Cause)qThe size definition of the component is wrong.wSome
obstacle so as bumper is at the corner position and had been
detected.eBecause some shape information so as number of leads
is not correct, and the camera recognition had reported wrong com-
ponent position on the pipet.
(Remedy)qCorrect size info..wIf the component is in the specifi-
cation, adjust the Co-Pl level in component info.eCorrect the shape
data.
(Meaning)The number of the leads detected by co-planarity check-
ing is different from the definition.
(Cause)qShape data in the component info. so as size, pitch, num-
ber of leads is wrong.wSome lead is off.eSome lead could not
detected by the laser scanning.
(Remedy)qCorrect the data in the SHAPE page.wDispose or re-
pair the component.eFirst, adjust the Co-Pl level in component
info. If the adjusting did not solve the problem, the lower surface of
the component is too dirty enough to be disposed or repaired.
(Meaning)The height of 2 neighbor leads in 1 side has too much
difference and is over the Co-Pl threshold.
(Cause)Some leads are damaged.
(Remedy)Dispose component, or repair the component, or use big-
ger value as Co-Pl threshold.
(Meaning)qA lead top is out of the tolerance in Co-Pl threshold
compare to the averaged line of the lead top in A side.wA lead top
is out of the tolerance in Co-Pl threshold compare to the averaged
surface of all leads of the component.
(Cause)A lead is damaged. Or the average height of all leads in A
side is out of the tolerance in Co-Pl threshold compare to the aver-
aged surface of all leads of the component.
(Remedy)Dispose component, or repair the component, or use big-
ger value as Co-Pl threshold.
(meaning)An emergency stop has occurred.
(cause)An emergency stop has occurred because of trouble with
the machine, or because the Emergency Stop button was pressed.
(remedy)Check safety factors and press the Ready button.
(meaning)This is not an error message.
(cause)None
(remedy)None
(meaning)The motor shaft has not completed its return to the origin
position.
(cause)A return to the origin position was not carried out after the
power supply was turned on.
(remedy)Use the command window to specify an origin position
return.
(meaning)This is not an error message.
(cause)None
(remedy)None
Ea00104
Ea00105
Ea00107
Ea00108
Ea00110
Ea00111
Ea00112
Ea00113
Ea00114
Ea00115
Ea00116
Ea00117
Ea00118
Ea00119
Ea00120
Ea00124
Be careful for Safety !!!
Machine axes will move to dump point.
[ENTER] : execute
[Others] : abort
Insert installation disk or upgrade disk to floppy drive,
and turn off the power, and turn on the power again.
This command had been disabled.
To install/upgrade software, start up [VIOS SOFTWARE
UTILITY] and execute next command.
2. Update of VIOS Soft
3. Installation of System Data
This command had been disabled.
To update system data backup, start up [VIOS SOFT-
WARE UTILITY] and execute next command.
4. Backup of System Data
RETURNING TO ORIGIN. PLEASE WAIT.....
Hit any key to RESET running, or..
Hit the [ESC] key not to RESET.
Now reading data.
Please wait a moment....
PCB DATA ERROR
No PCB selected.
This command is not (yet) available.
COMMAND ERROR
Now writing data.
Please wait a moment....
RESET is now active.
Please wait a moment....
Initializing All Production History
Please wait a moment....
Release the EMERGENCY switch and push the READY
key to activate the servo for searching the origin.
This command is not available when the machine is run-
ning. Please stop the machine first.
=== Now head vacuum is ON.===
After resetting, vacuum power will be OFF. If component
is on head, it is dangerous to drop component on that
spot independent of dumping way defined in Component
Information.
In case you don't want to drop it, push EMG-BOTTOM
and check safety, and please remove it.
This command is not available if machine is not reset.
Please reset the machine first.
(meaning)This is an axis movement warning message which ap-
pears when a component is discarded while the power supply is off,
or under other circumstances.
(cause)None
(remedy)To move the axis, press the Enter key. If the axis cannot be
moved because it is dangerous, press any other key.
(meaning)In order to upgrade the software, this indicates that the
Install disk or Upgrade disk should be inserted and the power sup-
ply turned off and then on again.
(cause)None
(remedy)With the disk inserted, turn the power supply off and then
on again.
(meaning)This command has been disable.
(cause)This command has been deleted.
(remedy)Use command of [VIOS SOFTWARE UTILITY]
(meaning)This command has been disable.
(cause)This command has been deleted.
(remedy)Use command of [VIOS SOFTWARE UTILITY]
(meaning)Return to origin position is in progress.
(cause)None
(remedy)None
(meaning)This is a confirmation message asking whether it is all
right to reset the system.
(cause)None
(remedy)To avoid a reset, press the ESC key.
(meaning)The system is waiting for the data reading process to end.
(cause)None
(remedy)Please wait.
(meaning)An attempt was made to run the system without specify-
ing a PCB name.
(cause)No PCB name has been specified.
(remedy)Specify the name of the PCB when the PCB being manu-
factured is switched.
(meaning)This command cannot be used.
(cause)A command was issued which cannot be used.
(remedy)Do not use this command.
(meaning)Data writing is in progress.
(cause)None
(remedy)Wait until the data writing process has been completed.
(meaning)A reset is in progress.
(cause)None
(remedy)Wait until the reset has been completed.
(meaning)The production history information is being initialized.
(cause)None
(remedy)Wait until the process has been completed.
(meaning)A return to the origin position cannot be executed be-
cause an emergency stop has occurred.
(cause)An attempt was made to execute a return to the origin posi-
tion during an emergency stop.
(remedy)Cancel the emergency stop and then select the return to
origin position command again.
(meaning)This command cannot be executed while the machine is
in operation.
(cause)A command was selected which cannot be executed during
automatic operation.
(remedy)Stop the machine before executing the command.
(meaning)A component had been picked up by the head when an
attempt was made to reset, so there is a possibility of the compo-
nent being dropped after the reset.
(cause)An attempt was made to reset with a component still on the
nozzle. An attempt was made to reset with the pickup valve of the
head still on.
(remedy)If a component has been picked up, release it before press-
ing the key.
(meaning)This command cannot be executed unless a reset has
been carried out.
(cause)A command was selected which cannot be executed with-
out carrying out a reset first.
(remedy)Carry out a reset before executing this command.