00195679-02_AI_XPS_DE EN - 第71页
13 Assembly Instructions 4 Installation of the XPL SIPLACE X-Series Productivity Shuttle T ype I/II 4.1 Mechanical Installation 4 Inst allation of the XPL The XPL consist s of two p arts that a re screwed to ge ther afte…
3 Preliminary Work on the SIPLACE X-Series Assembly Instructions
3.2 Routing and Connection of the Limit Switch Cable SIPLACE X-Series Productivity Shuttle Type I/II
12

13
Assembly Instructions 4 Installation of the XPL
SIPLACE X-Series Productivity Shuttle Type I/II 4.1 Mechanical Installation
4 Installation of the XPL
The XPL consists of two parts that are screwed together after installation in the placement system.
4.1 Mechanical Installation
1. Make sure that the width of the SIPLACE X-Series is adjusted to 100 mm.
2. In the as-delivered condition, both parts of the XPL are secured at their minimum width with
cable ties. Leave the cable ties until the parts are installed.
XPL Part 1 - Inlet XPL Part 2 - Outlet

4 Installation of the XPL Assembly Instructions
4.1 Mechanical Installation SIPLACE X-Series Productivity Shuttle Type I/II
14
3. Take XPL Part 1, which can be recognized by the aluminum strips at the inlet. Introduce it into
the placement system from the front so that it contacts the shaft bearings on the guide shafts
(∅
25 mm) of the SIPLACE.
CAUTION
The XPL is mounted on the conveyor below the Y-axis of the SIPLACE. Both the locating
conveyor for the transport walls and the Y-scale on the machine frames are located here.
Make certain that you do not damage these parts when inserting the XPL.
Aluminum strips at the inlet
of the first part of the XPL.
Shaft encoder in the center
of the connected XPL.
Shaft encoder at the inlet
and outlet of the XPL.
Introducing the XPL into the placement
system from the inlet side.