00195760-0102_UM_D3_SR605_EN - 第273页

User Manual SIPLACE D3 5 Tasks for the operating personnel From software version SR.605.xx 07/2008 EN Edition 5.7 Changing the set-up 273 5.7 Changing the set-up 5.7.1 Printing out the conversion inst ructions before cha…

100%1 / 364
5 Tasks for the operating personnel User Manual SIPLACE D3
5.6 Setting up the feeder modules From software version SR.605.xx 07/2008 EN Edition
272
Fig. 5.6 - 2 Inserting 30 or 45 mm wide S feeder modules on the component feeder table
(1) Feeder module, 30 mm wide
(2) Feeder module, 45 mm wide
(3) Centering ball
(4) Component table
User Manual SIPLACE D3 5 Tasks for the operating personnel
From software version SR.605.xx 07/2008 EN Edition 5.7 Changing the set-up
273
5.7 Changing the set-up
5.7.1 Printing out the conversion instructions before changing the set-up
Before a change of set-up, print out the conversion instructions on the printer for the SIPLACE Pro
computer as described in the "SIPLACE Pro" manual or in the online help.
5.7.2 What you should note when changing the feeder modules
Handle the feeder modules carefully when you insert them into or remove them from the com-
ponent feeder table. Make sure that the feeder modules do not bump against the component
table edges.
Vacuum the supporting surfaces of the feeder modules and clean the surface of the compo-
nent feeder table when necessary according to the instructions in the Preventive Mainte-
nance Manual.
CAUTION
Avoid removing components from the component table magnetic rail with your fingers. You
may hurt yourself with tiny splinters of metal. 5
Remove loose components using a brush or a vacuum cleaner with a suitable nozzle.
5 Tasks for the operating personnel User Manual SIPLACE D3
5.8 Avoiding track errors From software version SR.605.xx 07/2008 EN Edition
274
5.8 Avoiding track errors
5.8.1 General
Make sure that the areas around the feeder modules are clean and that there are no loose
components in the feeder area or under the feeder modules.
Ensure that the supporting surfaces of the feeder modules, and particularly the magnetic rails
of the component feeder tables, are clean and level.
Refill promptly with components.
Splice the tapes early. This generally means that you are to prepare the splicing material
when there is still approximately 1.5 m of tape on the reel.
Handle the feeder modules carefully when you insert them into or remove them from the com-
ponent table as these are high-precision devices.
Close the pick-up window on the feeder module as it could easily be damaged if you leave it
open.
Check that the pick-up position is set correctly for the components on the S feeder modules.
Check that the S feeder module plugs are connected to the right sockets.
5.8.2 Avoiding track errors with the tape container
Insert the separating plates correctly (see Fig. 5.5 - 2, page 268).
Tape reels with a diameter of 15" (381 mm) or more should be stored on spindles.
When using type 3 x 8 mm S feeder modules make sure to use the support for the middle
tape reel (see Section 3.10.8
, page 173).