User Manual SIPLACE D3 2 Operational safety
From software version SR.605.xx 07/2008 EN Edition 2.11 ESD guidelines
95
2.11 ESD guidelines
2.11.1 What does ESD mean?
Almost all of the modules in use today are equipped with highly integrated MOS blocks and com-
ponents. The manufacturing techniques used mean that these electronic components are ex-
tremely sensitive to overvoltage and thus to electrostatic discharge.
The abbreviation for such modules is 'ESD' (Electrostatic Sensitive Device). ’ESD’ is used inter-
nationally. The following symbol on cabinet rating plates, racks or packaging indicates that com-
ponents which are sensitive to electrostatic discharge have been used and thus that the modules
concerned are also touch-sensitive.
ESDs can be destroyed by voltages and power levels that are far below the level
that can be perceived by humans. Such voltages occur if a person touches a com-
ponent or module without earthing themselves. Components that are exposed to
such overvoltages do not generally appear to be defective immediately - incorrect
behavior starts after the component or module has been in operation for some time.
2.11.2 Important measures to protect against static charging
Most plastics can easily become charged and must therefore be kept away from at-risk com-
ponents.
Always ensure that people, the workplace and packaging are safely earthed when handling
electrostatic sensitive components.
2.11.3 Handling ESD modules
Do not touch electronic modules unless it is absolutely essential to do so in order to carry out other
work. If it is necessary, make sure that you do not touch the pins or printed conductors when you
pick up flat modules.
Do not touch components unless
you are constantly earthed by an ESD wrist strap or
you are wearing ESD shoes or ESD shoe earthing strips on an ESD floor.
Always discharge yourself before you touch an electronic module. To do this, simply touch a con-
ductive and earthed object immediately before you touch the module (such as unpainted parts of
a switch cabinet, a water pipe, etc.).
Do not allow modules with chargeable and highly insulating materials to touch one another, e.g.
plastic films, insulating table surfaces or items of clothing made from synthetic fibers.
2 Operational safety User Manual SIPLACE D3
2.11 ESD guidelines From software version SR.605.xx 07/2008 EN Edition
96
Always place the modules on a conductive surface (table with an ESD coating, conductive ESD
foam, ESD bag or container).
Do not bring modules near visual display units, monitors or televisions. Keep them at least 10 cm
away from the screen.
2.11.4 Measurements and modifications to ESD modules
Do not take measurements on the modules unless the following conditions are fulfilled:
The measuring device is earthed (e.g. via PE conductors) or
you discharge the measuring head just before taking measurements with a potential-free
measuring device (e.g. by touching an unpainted metal part of the controller casing).
Always use an earthed soldering iron if you carry out any soldering work.
2.11.5 Dispatching ESD modules
Always store modules and components in conductive packaging (e.g. metallized plastic bags
or metal sleeves) and dispatch them in conductive packaging.
If the packaging is not conductive, place the modules in a conductive envelope before pack-
aging. Use conductive expanded rubber, ESD bags, domestic aluminum foil or paper, for ex-
ample. NEVER use plastic bags or film. 2
If the module has integral batteries, ensure that the conductive packaging does not touch or
short-circuit the battery terminals and, if necessary, first cover the terminals with insulating
tape or material.
User Manual SIPLACE D3 3 Technical data for the machine
From software version SR.605.xx 07/2008 EN Edition 3.1 Performance data
97
3 Technical data for the machine
3.1 Performance data
3
3
3
3
Types of placement
head
12-segment Collect&Place head (C&P12)
6-segment Collect&Place head (C&P6)
SIPLACE TwinHead (TH)
PLEASE NOTE IPC value [comp./h]
According to the vendor-neutral conditions of the IPC 9850 standard published
by the Association of Connecting Electronics Industries.
SIPLACE Benchmark value [comp./h]
The SIPLACE benchmark value is measured during the machine acceptance
tests. It corresponds to the conditions set out in the SIPLACE scope of service
and supply.
Theoretical maximum output value [comp./h]
The theoretical maximum output value is calculated from the most favorable con-
ditions for each machine type and setting, and corresponds to the theoretical
conditions normally used in the industry.
Number of gantries 3
Placement area 1 Placement area 2 IPC value
[comp./h]
Benchmark value
[comp./h]
Theoretical value
[comp./h]
C&P12 / C&P12 C&P12 37,600 40,400 61,000
C&P12 / C&P12 C&P6 33,200 36,200 52,500
C&P12 / C&P12 TH 28,800 31,400 47,000
C&P12 / C&P6 C&P6 28,500 30,100 43,500
C&P12 / C&P6 TH 24,100 25,300 38,500
C&P12 / TH TH 21,300 23,800 33,500
C&P6 / C&P6 C&P6 25,100 28,100 34,500
C&P6 / C&P6 TH 20,700 23,300 29,500
C&P6 / TH TH 16,900 19,400 24,500
TH / TH TH 11,600 12,500 19,500
Placement posi-
tions
6,000 / gantry for the Collect&Place heads
2,000 / gantry for the TwinHead
Component range 0.6 x 0.3 mm² (0201)
to 85 x 85 mm² / 125 x 10 mm²,
max. 200 x 125 mm² (with restrictions)
Component
height
C&P12: 6 mm
C&P6: 8.5 mm
TH: 25 mm (larger heights available on request)
a