User Manual - Productivity Lift 3 Assembling and installing Edition 02/2004 3.1 Installation and operating instructions 41 3 Assembling and inst alling DANGER The assembly and inst allation of the Productivity Li f t (Li…

100%1 / 110
2 Operating safety User Manual - Productivity Lift
2.6 Signal lamps Edition 02/2004
40
Fig. 2 - 34 Fit the transport lock (clamping piece) from below against the shuttle conveyor
2.6 Signal lamps
The machine is equipped with a green and a white signal lamp. The following functions are allo-
cated to the lamps:
Green - lit : Unit is running in automatic mode.
White - lit : Unit has an error
Locking of the Shuttle Trans-
port via mounting transport
lock „clamping piece“.
BEFORE all intervention into the lift inte-
rior, when the shuttle conveyor is up
Shuttle-conveyor in UPPER position:
Check the clamping piece is securely fit-
ted!
User Manual - Productivity Lift 3 Assembling and installing
Edition 02/2004 3.1 Installation and operating instructions
41
3 Assembling and installing
DANGER
The assembly and installation of the Productivity Lift (Lift unit and SPLC) may only be carried out
by service technicians from SIEMENS AG L&A or service technicians from the customer, who
have been trained and therefore authorised for these tasks at SIEMENS AG L&A.according to the
requirements in the Productivity Lift installation instructions (Article-No. 00191967-02 / Edition 05/
2004).
HINWEIS
The existing installation and maintenance manuals are valid for the installation of the unit and its
maintenance.
There are detailed instructions for transportation of the machine in the installation instructions.
3.1 Installation and operating instructions
For the installation and operating instructions please refer to the chapter 9.1 “Installation and op-
erating instructions” and 9.2 “Electrical and pneumatic connection”.
3.2 Switching the device on
Once the device has been switched on at the main switch, an emergency stop message appears
in the display, which must be confirmed using the "Enter" key. This will set the device to the stand-
by-operating mode.
Pressing the "Start" key sets the device to the automatic operating mode, which begins by running
an initialisation phase. This serves to test basic system functions.
Following this brief initialisation, the device is set to the automatic operating mode and is ready to
operate.
3 Assembling and installing User Manual - Productivity Lift
3.3 Installation / Reinstallation of emergency conveyor Edition 02/2004
42
3.3 Installation / Reinstallation of emergency conveyor
The emergency conveyor is used, when the shuttle is not in use e.g. for reasons of maintenance.
3.3.1 In order to activate the emergency conveyor do the following:
1. By pushing the "stop" cursor the corresponding conveyor is put into stand-by mode.
2. Through "ALT" cursor the adjustment mode comes up.
3. Through the "Enter" cursor the menu comes up on the display which shows "PCB takeover"
comes up and you can check if the adjustment is "dual lane". If this is not the case one can
switch to "dual lane" as described in the chapter 6.3.
4. Use the "enter" cursor. The menu "PCB transfer" comes up. Here it is the same procedure as
described in point 3 (see chapter 6.6).
5. Another use of the "enter" cursor brings up the menu "PCB pass-through". In this menu the
emergency conveyor can be switched on by choosing the adjustment "switched on" (see chap-
ter 6.7). This change can be taken over with the "enter" cursor.
6. The adjustment mode can be quit with the "stop" cursor.
If the machine is started now the lift conveyor drives down and the emergency conveyor lowers to
the operating position and starts itself. Afterwards the device is again in operation mode.