Productivity Lift - 第50页
3 Assembling and installing User Manual - Productivity Lift 3.3 Installation / Reinstallation of emergency conveyor Edition 02/2004 42 3.3 Inst allation / Reinst allation of emergency conveyor The emergency conveyor is u…

User Manual - Productivity Lift 3 Assembling and installing
Edition 02/2004 3.1 Installation and operating instructions
41
3 Assembling and installing
DANGER
The assembly and installation of the Productivity Lift (Lift unit and SPLC) may only be carried out
by service technicians from SIEMENS AG L&A or service technicians from the customer, who
have been trained and therefore authorised for these tasks at SIEMENS AG L&A.according to the
requirements in the Productivity Lift installation instructions (Article-No. 00191967-02 / Edition 05/
2004).
HINWEIS
The existing installation and maintenance manuals are valid for the installation of the unit and its
maintenance.
There are detailed instructions for transportation of the machine in the installation instructions.
3.1 Installation and operating instructions
For the installation and operating instructions please refer to the chapter 9.1 “Installation and op-
erating instructions” and 9.2 “Electrical and pneumatic connection”.
3.2 Switching the device on
Once the device has been switched on at the main switch, an emergency stop message appears
in the display, which must be confirmed using the "Enter" key. This will set the device to the stand-
by-operating mode.
Pressing the "Start" key sets the device to the automatic operating mode, which begins by running
an initialisation phase. This serves to test basic system functions.
Following this brief initialisation, the device is set to the automatic operating mode and is ready to
operate.
3 Assembling and installing User Manual - Productivity Lift
3.3 Installation / Reinstallation of emergency conveyor Edition 02/2004
42
3.3 Installation / Reinstallation of emergency conveyor
The emergency conveyor is used, when the shuttle is not in use e.g. for reasons of maintenance.
3.3.1 In order to activate the emergency conveyor do the following:
1. By pushing the "stop" cursor the corresponding conveyor is put into stand-by mode.
2. Through "ALT" cursor the adjustment mode comes up.
3. Through the "Enter" cursor the menu comes up on the display which shows "PCB takeover"
comes up and you can check if the adjustment is "dual lane". If this is not the case one can
switch to "dual lane" as described in the chapter 6.3.
4. Use the "enter" cursor. The menu "PCB transfer" comes up. Here it is the same procedure as
described in point 3 (see chapter 6.6).
5. Another use of the "enter" cursor brings up the menu "PCB pass-through". In this menu the
emergency conveyor can be switched on by choosing the adjustment "switched on" (see chap-
ter 6.7). This change can be taken over with the "enter" cursor.
6. The adjustment mode can be quit with the "stop" cursor.
If the machine is started now the lift conveyor drives down and the emergency conveyor lowers to
the operating position and starts itself. Afterwards the device is again in operation mode.

User Manual - Productivity Lift 3 Assembling and installing
Edition 02/2004 3.3 Installation / Reinstallation of emergency conveyor
43
3.3.2 Stop of emergency conveyor
To stop the emergency conveyor the procedure described above has to be made the other
way round:
1. By pushing the "stop" cursor the corresponding conveyor is put into stand-by mode.
2. Through "ALT" cursor the adjustment mode comes up.
3. Through the "Enter" cursor the menu comes up on the display which shows "PCB takeover"
comes up and you can chose the adjustment as used before the emergency conveyor (see
chapter 6.3).
4. Use the "enter" cursor. The menu "PCB transfer" comes up. Here it is the same procedure as
described in point 3 (see chapter 6.6).
5. Another use of the "enter" cursor brings up the menu "PCB pass-through". In this menu the
emergency conveyor can be switched off by choosing the adjustment "switched off" (see chap-
ter 6.7). This change can be taken over with the "enter" cursor.
6. The adjustment mode can be quit with the "stop" cursor.
The device can be started with the "start" cursor. After an initialising time the device is ready for
operation.
NOTE
Pay attention that the changes made in chapter 6.3 and 6.6 are set back to the adjustments as
before activated.