6 Set-up mode User Manual - Productivity Lift Soko 00166631-01 / 12031477 6.5 Ramp up mode / Ramp down mode Software version V 43.140 Edition April 2006 72 6.5.2 Ramp up mode PCB distribution paramete r , which defines t…

User Manual - Productivity Lift Soko 00166631-01 / 12031477 6 Set-up mode
Software version V 43.140 Edition April 2006 6.5 Ramp up mode / Ramp down mode
71
6.5.1.2 Last Siplace is out of order and the last lift is running in emergency service mode
Fig. 6 - 8 Example line
E
i
n
g
a
n
g
s
m
o
d
u
l
I
n
p
u
t
m
o
d
u
l
e
Belademodus 1:1
Ramp up mode -
Z
w
i
s
c
h
e
n
m
o
d
u
l
C
l
u
s
t
e
r
m
o
d
u
l
e
E
n
d
m
o
d
u
l
E
n
d
m
o
d
u
l
e
N
o
t
b
e
t
r
i
e
b
E
m
e
r
g
e
n
c
y
S
e
r
v
i
c
e
Belademodus 1:0
Entlademodus 1:0
Ramp up mode 1:0
Ramp down mode 1:0
Belademodus -
Entlademodus 1:1
Ramp up mode -
Ramp down mode 1:1
Durchlauf
Pass through

6 Set-up mode User Manual - Productivity Lift Soko 00166631-01 / 12031477
6.5 Ramp up mode / Ramp down mode Software version V 43.140 Edition April 2006
72
6.5.2 Ramp up mode
PCB distribution parameter, which defines the loading sequence of the PCBs within a cluster of
Siplace units. The value of x depends on the number of Siplace units within a cluster.
The menu allows to set the value x between 0...9.
Fig. 6 - 9 Ramp up mode
6.5.3 Ramp down mode
PCB distribution parameter, which defines the unloading of the PCBs within a cluster of Siplace
units. The value of x depends on the number of Siplace units within a cluster.
The menu allows to set the value x between 0...9.
Fig. 6 - 10 Ramp down mode
ALT
Enter
Start
Stop
Ramp up mode
1 to x
ALT
Enter
Start
Stop
Ramp down mode
1 to x

User Manual - Productivity Lift Soko 00166631-01 / 12031477 6 Set-up mode
Software version V 43.140 Edition April 2006 6.5 Ramp up mode / Ramp down mode
73
6.5.4 Availability of Ramp up / Ramp down mode depending on machine type
The ramp up, ramp down mode depends on the selected machine type as defined in the table be-
low.
6.5.5 Required set-up Ramp-up / Ramp down
For the allowed line configuration with three Single Conveyor Productivity Lifts, and two similar
placement machines following set-up is required:
Lift 1: Input Module, Ramp-up 1:1
Lift 2: Cluster Module, Ramp-up 1:0, Ramp-down 1:0
Lift 3: Output Module, Ramp-down 1:1
6.5.6 Required set-up Ramp-up / Ramp down
For the allowed line configuration with four Single Conveyor Productivity Lifts, and three similar
placement machines following set-up is required:
Lift 1: Input Module, Ramp-up 1:2
Lift 2: Cluster Module, Ramp-up 1:1, Ramp-down 1:0
Lift 3: Cluster Module, Ramp-up 1:0, Ramp-down 1:1
Lift 4: Output Module, Ramp-down 1:2
Input module
Cluster module
Cross module
Convert 2/4
Convert 4/2
Output module
Ramp up mode
X X X
Ramp down mode
X X X