Softw are Vers ionsbes c hreibung Softw are Vers ion Des cr iption SIPL ACE Ex plo rer V2.7 20 von 56 5.6 Possible Placement D at a Deviations Between SIP LACE Expl orer and OIS The num ber of cons umed component s, reje…
Software Versionsbeschreibung Software Version Description SIPLACE Explorer V2.7
19 of 56
• OIS 4.0, SIS 4.0, SIPLACE Pro 4.0
• OIS 3.1, SIS 3.1, SIPLACE Pro 3.2
The following versions are supported but if problems should occur, you will need to update the versions to
those shown above.
• OIS2.4 SP1, SIS 1.2 SP1, SIPLACE Pro 2.1 SP2
SIPLACE Explorer V2.7 supports data from the following station software versions:
• SW 704
• SW 703
• SW 702
• SW 701
• SW 605
• SW 604
• SW 603
• SW 602
• SW 601
• SW 505
• SW 407
• SW 408
• SW 101 for the CS and CF machine
The following version is supported but if problems should occur, you will need to update to the version
shown above.
• SW 503.04 SP 2, this version is only suitable if hardware restrictions do not permit an upgrade to
SW 505.xx.
5.5 Interfaces
SIPLACE Explorer does not provide any interfaces. However, a connection to OIS and SIS does exist, as
SIPLACE Explorer receives all required data from the OIS and SIS via so-called database views. For
further information about OIS and SIS database views, please see the following descriptions:
• Interface Description Operator Information System / Setup Information System Database V8.0,
Item No.: 00196640-01.
Software Versionsbeschreibung Software Version Description SIPLACE Explorer V2.7
20 von 56
5.6 Possible Placement Data Deviations Between SIPLACE
Explorer and OIS
The number of consumed components, rejects and boards can differ between SIPLACE Explorer and
OIS.
In OIS, each data set has a time stamp (consumed components, rejected components and each board).
If you start an OIS query for the consumption within a specific time period, via SQL Query, OIS will issue
the number of data sets which have a time stamp within this period.
SIPLACE Explorer, on the other hand, assigns the components to the boards on which they are to be
placed. If you start a query for the consumption within a specific time period, SIPLACE Explorer will issue
the number of components which have been placed on the boards which were produced within the
defined period. This difference becomes clearer when we consider production in 2 placement areas.
The following diagram illustrates the difference.
Example: 8 boards were placed on a machine with 2 placement areas. The diagram shows 3 timelines:
• Components for placement area 1
• Components for placement area 2
• Boards
The components X on the timeline for placement area 1 show the possible timestamps for those
components which were placed on board X.

Software Versionsbeschreibung Software Version Description SIPLACE Explorer V2.7
21 of 56
If you start an OIS query via SQL Query, for the time between T1 and T2, the result will show the total
number of components which were placed on all 8 boards minus the number of components which were
placed on board 1 of placement area 1.
If you start the same query via SIPLACE Explorer, the result will show the total number of components
which were placed on all 8 boards.
In this example, the result in SIPLACE Explorer will be higher than the number shown in OIS.
However, this is not always the case. If board 9 is placed (in placement area 1 in the diagram), SIPLACE
Explorer will not count the components which were placed on this board and will therefore show fewer
components as the OIS.
For this reason, there will also be deviations between OIS and SIPLACE Explorer in the determination of
component reject numbers.
5.7 Status Display Deviations Between SIPLACE Explorer and OIS
There is a special OIS status module realized in SIPLACE OIS. This OIS status module is shown in the
SIPLACE Explorer status module which matches the SEMI E10 status module. This may lead to
deviations in the states and status times shown between OIS and SIPLACE Explorer. A direct
comparison is therefore not possible.