00196744-01 - VD SIPLACE Explorer 2.7_de_en - 第25页
Softw are Vers ionsbes c hreibung Softw are Vers ion Des cr iption SIPLAC E Ex plorer V2. 7 25 of 56 • Single Line Layout A SI PLACE E xplorer hos t (t he comput er on which SI PLACE E xplorer Runt ime Env ironment is in…
Software Versionsbeschreibung Software Version Description SIPLACE Explorer V2.7
24 von 56
5.8 Existing Restrictions
SIPLACE Explorer Version 2.7 has the following restrictions:
• When using MS Windows 7 with 64 Bit, you must install Adobe Reader 9.x manually otherwise the
online help cannot be opened via the websites. The Support Media DVD provides the Adobe
Reader 9.x in the "\TOOLS\ACROBAT READER" folder.
• When upgrading from SIPLACE Explorer versions 2.2 and older to SIPLACE Explorer 2.7 the
Apache Tomcat web server has to be uninstalled first and afterwards be reinstalled from the
Support Media DVD. In doing so, you make sure that the correct Java version 1.6 is set for the
Apache Tomcat web server.
• For all versions lower than SIPLACE Pro 7.0, OIS 7.0 and station software 703, SIPLACE Explorer
2.7 shows "N/A" instead of the PCB side on the Overview tab of the factory website.
• For all versions lower than SIPLACE Pro 7.0, OIS 7.0 and station software 703, SIPLACE Explorer
2.7 shows "-" instead of the PCB side in the Current Recipe List table on the Production
Summary website.
• Restriction due to NPI mode
SIPLACE Explorer V2.7 is unable to use data from SIS for boards which are marked as "SA"
(stand-alone). This means that the following information is not available for boards marked with
"SA":
• Component name
• Component shape
• Feeder type
• The following pages show limited data due to the "Stand-alone" mode:
• Pickup reliability
• Pickup overview
• Reject volume
• Status transitions
• Factory Layout:
A SIPLACE Explorer host (the computer on which SIPLACE Explorer "Runtime Environment" is
installed) can monitor five production lines with up to 20 stations.
Software Versionsbeschreibung Software Version Description SIPLACE Explorer V2.7
25 of 56
• Single Line Layout
A SIPLACE Explorer host (the computer on which SIPLACE Explorer Runtime Environment is
installed) can monitor one production line with up to 7 stations.
• For performance reasons, we recommend that you do not generate reports for all websites and
report types at once. Try to run the report generation at a time when there is no production
operation e.g. at the weekend.
• From SIPLACE Explorer Version 2.0 SP1, the station GEM interface will no longer be supported
i.e. data can not be recorded via the GEM interface with SIPLACE Explorer Version 2.5 or higher.
If you need support for the GEM interface, please contact the SIPLACE Hotline.
• The system time on the connected machines and that belonging to the SIPLACE Explorer must be
synchronized. SIPLACE machines require the installation of TimeSync, which is included on the
Support Media DVD provided with the delivery.
• The following restriction applies to platform I (S20, S23, F4, F5, F5HM) stations with dual
conveyors:
The page Production Summary will display Unknown in the Current Recipe List table for the
2nd conveyor lane.
Reason:
Platform I stations are unable to produce different recipes, even with dual conveyors. Therefore,
only one recipe will be loaded for the SIPLACE production line. This recipe will then only be
assigned to conveyor lane I by SIPLACE Explorer.
• When using the conveyor type "dual conveyor", the board counting function is subject to
limitations. It only records boards for conveyor lane 1. Boards produced on conveyor lane 2 are not
recorded.
SIPLACE Explorer and OIS only show the boards for conveyor lane 1.
The components placed on the boards on conveyor lane 2 are assigned to the boards recorded for
lane 1. This means that the number of consumed components shown is correct.
This restriction applies to the following software versions: 407, 408, 502, 503, 504, 505.01, 505.02.
The restriction ceases to apply for version 505.03 onwards.
Software Versionsbeschreibung Software Version Description SIPLACE Explorer V2.7
26 von 56
• If partially placed boards are removed from the SIPLACE machine, without specifying this
termination in the station software and removing them via the output conveyor, these boards will
not be recorded by the OIS and SIPLACE Explorer systems. In this case, the station software is
not able to generate the data set needed to record the boards. This restriction applies to all
available versions of the station software.
If you need to terminate board placement, always proceed as follows:
• Terminate the board at the station software interface.
• Remove the board from the output conveyor of the station and not by opening the hood and
taking it directly out of the placement area.
• The following restrictions apply to the SMA pages listed below, if no boards are placed at the last
station in the production line:
• Machine Navigator:
OLE value will not be shown (N/A).
• OLE / OEE Overview:
Overall Line Efficiency diagram: Values for OLE, performance and availability will not be
shown correctly.
Overall Equipment Efficiency by station diagram: station data is not shown correctly for
stations which do not place boards.
• OEE Analysis:
Table: Values for performance and availability will not be shown correctly for production lines
and stations which do not place boards.
Overall Equipment Efficiency diagram – comparison diagram: Values for OEE,
performance and availability will not be shown correctly for the production line.
• When using MS Windows 2003 Server, the Webhost (Tomcat) must be configured accordingly.
For further details about the configuration process, refer to the document "SIPLACE Explorer 2.7
Installation and Configuration Manual", Item No.: 00196742-01.
• Due to a restriction from the Microsoft DNS service, the name of the computer on which Tomcat
is installed must include no special characters, in particular no underscore (_). If the name does
include these characters, it will not be possible to display the website. For further details about