If partially placed boards are removed from the SIPLACE machine, without specifying this
termination in the station software and removing them via the output conveyor, these boards will
not be recorded by the OIS and SIPLACE Explorer systems. In this case, the station software is
not able to generate the data set needed to record the boards. This restriction applies to all
available versions of the station software.
If you need to terminate board placement, always proceed as follows:
Terminate the board at the station software interface.
Remove the board from the output conveyor of the station and not by opening the hood and
taking it directly out of the placement area.
The following restrictions apply to the SMA pages listed below, if no boards are placed at the last
station in the production line:
Machine Navigator:
OLE value will not be shown (N/A).
OLE / OEE Overview:
Overall Line Efficiency diagram: Values for OLE, performance and availability will not be
shown correctly.
Overall Equipment Efficiency by station diagram: station data is not shown correctly for
stations which do not place boards.
OEE Analysis:
Table: Values for performance and availability will not be shown correctly for production lines
and stations which do not place boards.
Overall Equipment Efficiency diagram – comparison diagram: Values for OEE,
performance and availability will not be shown correctly for the production line.
When using MS Windows 2003 Server, the Webhost (Tomcat) must be configured accordingly.
For further details about the configuration process, refer to the document "SIPLACE Explorer 2.7
Installation and Configuration Manual", Item No.: 00196742-01.
Due to a restriction from the Microsoft DNS service, the name of the computer on which Tomcat
is installed must include no special characters, in particular no underscore (_). If the name does
include these characters, it will not be possible to display the website. For further details about
this restriction, see "http://support.microsoft.com/kb/275033".
Software Versionsbeschreibung Software Version Description SIPLACE Explorer V2.7
27 of 56
6 Installation
For detailed information about the installation and configuration process, refer to the document "SIPLACE
Explorer 2.7 Installation and Configuration Manual", Item No.: 00196742-01. This includes a description
of the installation process via the install shield wizard and details of manual configurations to be
performed.
Software Versionsbeschreibung Software Version Description SIPLACE Explorer V2.7
28 von 56
7 Corrected Errors
Error
number
Description of error
D1-48004067
Filtering by shifts was not done correctly on the Websites Performance and
Production Summary.
D1-50636301 Installing SIPLACE Explorer sporadically failed if the Microsoft Terminal
Service is installed on the same computer.
D1-53868284 The error that factory reports of individual lines did not show any data
occurred sporadically.
D1-54108389 If in subsequent job definitions components were to be placed on a station in
one definition and after that no more, the error could occur that 'N/A in SIS'
was displayed on the Website Reject Rate instead of the components and
component shape names.
D1-54152013 If in subsequent job definitions components were to be placed on a station in
one definition and after that no more, the error could occur that the E10 state
Scheduled Downtime Bypass repeatedly popped up while the state
Productive was displayed.
8 Known Problems
None
9 SIPLACE Error Reporting
SIPLACE Explorer V 2.7 provides SIPLACE Error Reporting, which can be used to record production line
errors which occur in SIPLACE Explorer and Tomcat. The files recorded can then be sent for error
analysis to the Siemens hotline or given to a Siemens service technician.
The following files are compiled by SIPLACE Error Reporting.