SOM-2079-001_w.pdf - 第124页
121 SOM-2079 異常 ID 異常名、説明、要因および復帰方法 4b1801 Flux spread error Component recognition is abnormal after flux spread. Since the picked-up components may have fallen on the turntable of flux spread equipment, please check it. 4…

120
SOM-2079
異常 ID 異常名、説明、要因および復帰方法
4b1103 Conveyance aging
Abnormalities occurred during backup base axis aging.
Please check motor, amplifier and unusual contents of servo. (NA-B axis, NC-B
axis).
4b1104 Conveyance aging
The timeout occurred in backup base axis operation during backup base axis
aging.
Please check motor, amplifier and unusual contents of servo. (NA-B axis, NC-B
axis).
4b1105 Conveyance aging
Abnormalities occurred during Y arrangement shuttle axis aging.
Please check motor, amplifier and unusual contents of servo. (NL-W1 axis,
NL-W2 axis, NR-W1 axis, NR-W2 axis).
4b1106 Conveyance aging
The timeout occurred in Y arrangement shuttle axis operation during Y
arrangement shuttle axis aging.
Please check motor, amplifier and unusual contents of servo. (NL-W1 axis,
NL-W2 axis, NR-W1 axis, NR-W2 axis).
4b1201 Press in error / Insertion error
There is an error with the component pressed in or Insertion
Open safety cover and confirm the component on P.C.B. Please remove it or
revise it
4b1301 Flux spread equipment error
Motor alarm was generated.
Please remove and check flux spread equipment.
4b1401 Flux auto reload timeout
Drum rotation movement was not completed within prescribed time.
-----
4b1402 Flux auto reload timeout
Flux automatic reload was not completed within prescribed time.
-----
4b1501 Flux shortage of supply
The number of dip times and the time of automatic running were beyond a set
value.
Please supply a flux.
4b1601 Flux auto reload error
There is an abnormality in the flux automatic reload.
-----
4b1701 Flux auto reload motion error
Flux automatic reload motion was not completed within prescribed number of
times.
(1) Please confirm flux in a syringe is not insuffi
ciency.
(2) Please confirm setting of the threshold of a flux residual quantity detection
sensor.
(3) Please confirm whether a flux is perfect to the tip of a tube.
1005-001
6.11 その他

121
SOM-2079
異常 ID 異常名、説明、要因および復帰方法
4b1801 Flux spread error
Component recognition is abnormal after flux spread.
Since the picked-up components may have fallen on the turntable of flux spread
equipment, please check it.
4b1802 Flux spread error
Component recognition is abnormal after flux spread.
(1) Please confi
rm whether a flux spread device is installed definitely.
(2) Please confirm whether there is a residual quantity of flux.
(3) Please confirm whether a film thickness of a flux is formed normally.
4b1803 Flux spread error
The abnormality that there is no component after flux spread.(Sensor)
Since the picked-up components may have fallen on the turntable of flux spread
equipment, please check it.
4b1901 Monoaxial zeroing is abnormal.
It detected abnormality during movement.
Please get rid of an abnormal factor
4b1902 Monoaxial zeroing is abnormal.
It is impossible of W2 axis zeroing.
Please perform W1 axis zeroing.
4b1a01 Process error
Failed in restoration of the Machine data.
Please execute restoration operation from NT again.
4b1a02 Process error
Failed in restoration of the Network data.
Please confi
rm the network setting.
4b1a03 Process error
Failed in data transfer.
Please reboot machine.
4b1a04 Process error
The machine operation has stopped after inside P.C.B.'s were transferred to the
out of the machine due to time-lag in the operation window process.
Reboot the machine. (Press the buttons of [Shutdown] →
[Reboot] in the login tab
sheet.)
4b2001 PCB Height Measurement
Abnormal measured value was detected.
Check the measurement position.
4b2002 PCB Height Measurement
Abnormality occurred for communication with a sensor
-----
4b2003 PCB Height Measurement
The abnormality number of times of measured value was beyond a set point.
Running is stopped.
-----
1005-001
6.11 その他

122
SOM-2079
異常 ID 異常名、説明、要因および復帰方法
4b2004 PCB Height Measurement
The abnormality number of times of measured value was beyond a set point.
-----
4b2005 PCB Height Measurement
A measurement result is abnormal(measure in arbitrary position)
Check the measurement position.
4b2006 PCB Height Measurement
Surpass a measurement range. (+ direction)
-----
4b2007 PCB Height Measurement
Surpass a measurement range. (- direction)
-----
4b2008 PCB Height Measurement
Detected a curve more than permission values. (+ direction)
-----
4b2009 PCB Height Measurement
Detected a curve more than permission values. (- direction)
-----
4b200a PCB Height Measurement
Error of the result measured by a master jig (height)
Check if the master jig (height) has some dirt and foreign particles.
4b200b PCB Height Measurement
Failed in wearing height revision.
-----
4b200c PCB Height Measurement
An abnormal measurement was detected by the multipoint measurement.
Check the measurement position.
4b200d PCB Height Measurement
Recovery by the multipoint measurement failed because the measurement result
was insufficient.
Check the measurement position.
4b2011 PCB Height Measurement
Measurement time-out
-----
4b2081 PCB Height Measurement
Abnormality occurred for communication with a sensor
-----
4b2082 PCB Height Measurement
Failed in wearing height revision.
-----
4b2083 PCB Height Measurement
Measurement time-out
-----
1005-001
6.11 その他