SOM-2079-001_w.pdf - 第126页
123 SOM-2079 異常 ID 異常名、説明、要因および復帰方法 4b2084 PCB Height Measurement The coordinate where the height measurement was impossible was appointed. Please appoint a coordinate in a measurable range. 4b2101 SSC network abnormal T…

122
SOM-2079
異常 ID 異常名、説明、要因および復帰方法
4b2004 PCB Height Measurement
The abnormality number of times of measured value was beyond a set point.
-----
4b2005 PCB Height Measurement
A measurement result is abnormal(measure in arbitrary position)
Check the measurement position.
4b2006 PCB Height Measurement
Surpass a measurement range. (+ direction)
-----
4b2007 PCB Height Measurement
Surpass a measurement range. (- direction)
-----
4b2008 PCB Height Measurement
Detected a curve more than permission values. (+ direction)
-----
4b2009 PCB Height Measurement
Detected a curve more than permission values. (- direction)
-----
4b200a PCB Height Measurement
Error of the result measured by a master jig (height)
Check if the master jig (height) has some dirt and foreign particles.
4b200b PCB Height Measurement
Failed in wearing height revision.
-----
4b200c PCB Height Measurement
An abnormal measurement was detected by the multipoint measurement.
Check the measurement position.
4b200d PCB Height Measurement
Recovery by the multipoint measurement failed because the measurement result
was insufficient.
Check the measurement position.
4b2011 PCB Height Measurement
Measurement time-out
-----
4b2081 PCB Height Measurement
Abnormality occurred for communication with a sensor
-----
4b2082 PCB Height Measurement
Failed in wearing height revision.
-----
4b2083 PCB Height Measurement
Measurement time-out
-----
1005-001
6.11 その他

123
SOM-2079
異常 ID 異常名、説明、要因および復帰方法
4b2084 PCB Height Measurement
The coordinate where the height measurement was impossible was appointed.
Please appoint a coordinate in a measurable range.
4b2101 SSC network abnormal
There is abnormal in SSC network.
Please confi
rm the cable of SSC network.
4b2102 SSC network abnormal
There is a problem with the connection between the position board MR-
MC10-U82 channel 1and amplifier.
(1)
Shut down the machine and check the connection between the position board
and amplifier.
(2) Check whether or not the multi-axis amplifier is damaged.
(3) Check whether or not the servo amplifiers are damaged.
4b2103 SSC network abnormal
There is a problem with the connection between the position board MR-
MC10-U82 channel 2and amplifier.
(1)
Shut down the machine and check the connection between the position board
and amplifier.
(2) Check whether or not the multi-axis amplifier is damaged.
(3) Check whether or not the servo amplifiers are damaged.
4b2104 SSC network abnormal
There is a problem with the connection between the position board MR-
MC10-U83 channel 1and amplifier.
(1)
Shut down the machine and check the connection between the position board
and amplifier.
(2) Check whether or not the multi-axis amplifier is damaged.
(3) Check whether or not the servo amplifiers are damaged.
4b2105 SSC network abnormal
There is a problem with the connection between the position board MR-
MC10-U83 channel 2 and amplifier.
(1)
Shut down the machine and check the connection between the position board
and amplifier.
(2) Check whether or not the multi-axis amplifier is damaged.
(3) Check whether or not the servo amplifiers are damaged.
4b2106 SSC network abnormal
There is a problem with the connection between the position board MR-
MC10-U84 channel 1 and amplifier.
(1)
Shut down the machine and check the connection between the position board
and amplifier.
(2) Check whether or not the multi-axis amplifier is damaged.
(3) Check whether or not the servo amplifiers are damaged.
1005-001
6.11 その他

124
SOM-2079
異常 ID 異常名、説明、要因および復帰方法
4b2107 SSC network abnormal
There is a problem with the connection between the position board MR-
MC10-U84 channel 2 and amplifier.
(1)
Shut down the machine and check the connection between the position board
and amplifier.
(2) Check whether or not the multi-axis amplifier is damaged.
(3) Check whether or not the servo amplifiers are damaged.
4b2108 SSC network abnormal
There is a problem with the connection between the position board MR-
MC10-U90 channel 1 and amplifier.
(1)
Shut down the machine and check the connection between the position board
and amplifier.
(2) Check whether or not the multi-axis amplifier is damaged.
(3) Check whether or not the servo amplifiers are damaged.
4b2109 SSC network abnormal
There is a problem with the connection between the position board MR-
MC10-U90 channel 2 and amplifier.
(1)
Shut down the machine and check the connection between the position board
and amplifier.
(2) Check whether or not the multi-axis amplifier is damaged.
(3) Check whether or not the servo amplifiers are damaged.
4b2201 Illegal Operation
There is no Pattern program file.
-----
4b2301 Feeder (Servo Error)
Alarm Code:A0 - Internal Parameter Error (Breakdown of Control PCB)
Please replace the feeder. (Do not disconnect the feeder in powering on,
otherwise it may cause the inside data broken.)
4b2302 Feeder (Servo Error)
Al
arm Code:A1 - Over Current Error (Foreign substances in the tape feeding drive
section)
Confirm whether or not the tape is being jammed on the path./ Confirm the reel to
operate smoothly./ Confirm whether or not some components and dust are being
caught in the sprocket./ Confirm whether or not some components and dust are
being caught in the
4b2303 Feeder (Servo Error)
Alarm Code:A2 - Others
-----
4b2304 Feeder (Servo Error)
Alarm Code:A3 - Others
-----
4b2305 Feeder (Servo Error)
Al
arm Code:A4 - Main Circuit Power Supply Error (Please check the power supply
voltage.) (G04)
Please check the power supply voltage.
1005-001