165 SOM-2079 装置情報コード 表示区分 A( 装置情報の概要 ) 表示区分 B( 装置情報の詳細 ) 800F06 Program Change Warning 800F07 Program Change Warning 800F81 Program Change Warning 800F82 Program Change Warning 800F83 Program Change Warning 800F84 Progra…

164
SOM-2079
装置情報コード 表示区分 A( 装置情報の概要 )
表示区分 B( 装置情報の詳細 )
800D05 Maintenance Warning
Keep the machine condition.(maintenance cycle time : Oil-Checkup/6-Monthlyy)
800D06 Maintenance Warning
Keep the machine condition.(maintenance cycle time : Oil-Checkup/Designate
#1)
800D07 Maintenance Warning
Keep the machine condition.(maintenance cycle time : Oil-Checkup/Designate
#2)
800D08 Maintenance Warning
Keep the machine condition.(maintenance cycle time : Upkeep-Checkup/Nozzle)
800D09 Maintenance Warning
Keep
t
he machine condition.(maintenance cycle time : Upkeep-Checkup/Filter #1)
800D0A Maintenance Warning
Keep t
he machine condition.(maintenance cycle time : Upkeep-Checkup/Filter #2)
800D0B Maintenance Warning
Keep the machine condition.(maintenance cycle time : Designate-Checkup/Item
#1)
800D0C Maintenance Warning
Keep the machine condition.(maintenance cycle time : Designate-Checkup/Item
#2)
800D0D Maintenance Warning
Keep the machine condition.(maintenance cycle time : Designate-Checkup/Item
#3)
800D0E Maintenance Warning
Component box fill up warning.(notice count over)
800D0F Maintenance Warning
It was the time of maintenance. [A flux unit] Please perform cleaning of a fl
ux
spin drum.
800E01 Program Change Warning
Check the set-up of machine.(program change completed)
800E02 Program Change Warning
Check the set-up of machine.(Program change completed. Run Mode changed to
"PASS".)
800F01 Program Change Warning
800F02 Program Change Warning
800F03 Program Change Warning
800F04 Program Change Warning
800F05 Program Change Warning
1005-001
6.19 装置情報

165
SOM-2079
装置情報コード 表示区分 A( 装置情報の概要 )
表示区分 B( 装置情報の詳細 )
800F06 Program Change Warning
800F07 Program Change Warning
800F81 Program Change Warning
800F82 Program Change Warning
800F83 Program Change Warning
800F84 Program Change Warning
801001 Auto Offset Teach Information
Tape pocket recog error(run continue)
801101 Nozzle diameter confi
rmation
The disagreement of the nozzle diameter was detected with the linear measure.
There is a possibility of the linear measure dirt and the nozzle dirt,please confirm
whether a different nozzle has adhered.
801201 Stat Auto Head Recovery
Cpu Communication error occurred.(CPU2-CPU3)
801202 Stat Auto Head Recovery
Head cam origin return action not complete.(Not CAM ORIGIN position)
801203 Stat Auto Head Recovery
Head Driver communication is time out.(from cpu3 job)
801204 Stat Auto Head Recovery
Nozzle change action not complete.(cam lock action NG)
801205 Stat Auto Head Recovery
Head cam position return action not complete.
801206 Stat Auto Head Recovery
Nozzle change action not complete.(cam free action NG)
801207 Stat Auto Head Recovery
Nozzle change action not complete.(Not CAM ORIGIN position)
801208 Stat Auto Head Recovery
Unselected Nozzle Drop.
801209 Stat Auto Head Recovery
Component output error(Pick-up error) is detected by nozzle level was position.
;Nozzle posture detection
80120a Stat Auto Head Recovery
The selected nozzle was not at position. ;Nozzle posture detection
80120b Stat Auto Head Recovery
Component
output error(Others) is detected by nozzle level was position. ;Nozzle
posture detection
801301 Pick-up Position Feedback
Feedback value out of range. Please check feeder.
1005-001
6.19 装置情報

166
SOM-2079
装置情報コード 表示区分 A( 装置情報の概要 )
表示区分 B( 装置情報の詳細 )
801401 Data Check
Pick-up Level Data(Calculated data) is out of range. Please check library data
and offset data.
801402 Data Check
Placement height Data(Calculated data) is out of range. Please check library data
and offset data.
801403 Data Check
The data out of the setting range is contained in the feeder offset B data of
system data. On edit screen, X/Y of the components (tape width 8mm / sending
pitch 2mm) should be set as more than -1.0mm and less than +1.0mm.
801404 Data Check
The data out of the setting range is contained in the placement level data of
component supply changed data. On edit screen, the place level of square shape
below 3216 should be set up less than +0.5mm. When the place level exceeding
0.5mm is required, please input H data of placement data (PP data).
801405 Data Check
Data other than 0 are input to H offset of the pattern program data (height data).
There is a possibility of the component damage when the component is placed.
Please confi
rm whether the input data is correct.
801501 Feeder Index Position
Production operation was interrupted in the middle of feeder index operation.
Please check a position.
801502 Feeder Index Position
The feeder carriage was returned to the home position in the middle of feeder
index operation. Please check a feeder index position.
801601 Product Restart
Restart production with semi-auto(after specified step) mode.
801602 Product Restart
Restart production with warm start mode.
801603 Product Restart
Restart production with warm start mode. Machine will stop after placement
complete. Please confirm PCB afterward.
801701 Teach Nozzle Bypass
Nozzle Down Error.(L)
801702 Teach Nozzle Bypass
Nozzle Down Error.(H)
801703 Teach Nozzle Bypass
Recognition Teach Error.
801704 Teach Nozzle Bypass
Teach Error Data.
801705 Teach Nozzle Bypass
Lighting Check.
801706 Teach Nozzle Bypass
Nozzle Level.
1005-001