SOM-2079-001_w.pdf - 第178页

175 SOM-2079 6.20 システム異常 Table 22 異常 ID 異常名、説明、要因および復帰方法 FE0101 Auto Control Error In auto control the operation can't be continued Error(Refer to syslog) ----- 1005-001 6.20 システム異常

100%1 / 179
174
SOM-2079
装置情報コード 表示区分 A( 装置情報の概要 )
表示区分 B( 装置情報の詳細 )
809a01 Tray Resupply
Release the lock of the safety cover in the tray resupply section and change the
tray.
After change, lock the cover and press the Resupply button.
809b01 P.C.B. height measure
The measurement had an error but it has been recovered by measuring the
multiple points.
809b02 P.C.B. height measure
Abnormal measured value was found but it has been recovered by measuring the
multiple points.
809C01 Library Bulk Feeder Check
The bulk feeder of library is not in agreement. Please check the library and bulk
feeder.
809d01 Cutter auto return
The cutter auto return mode was performed.
809e01 Shuttle Tray Pickup Loc
The P&P X axis position is limit over(+). Please check the comp position.
809e02 Shuttle Tray Pickup Loc
The P&P X axis position is limit over(-). Please check the comp position.
809e03 Shuttle Tray Pickup Loc
The traverse axis position is limit over(+). Please check the comp position.
809e04 Shuttle Tray Pickup Loc
The traverse axis position is limit over(-). Please check the comp position.
809e05 Shuttle Tray Pickup Loc
The shuttle axis position is limit over(+). Please check the comp position.
809e06 Shuttle Tray Pickup Loc
The shuttle axis position is limit over(-). Please check the comp position.
1005-001
6.19 装置情報
175
SOM-2079
6.20 システム異常
Table 22
異常 ID 異常名、説明、要因および復帰方法
FE0101 Auto Control Error
In auto control the operation can't be continued Error(Refer to syslog)
-----
1005-001
6.20 システム異常
不許複製
2010 5 初版発行
編集および発行所
1005-001
SOM-2079
360-0238 埼玉県熊谷市妻沼西一丁目 6 番地
TEL:(048)506-6086 FAX:(048)567-0084