31 SOM-2079 1005-001 異常 ID 異常名、説明、要因および復帰方法 425201 Output Cnvr PCB Detection PCB's were at inlet and outlet of cnvr. Por favor, verifique posicionamento da PCB no conveyor e continue a operação 425202 Output Cnvr PCB…

100%1 / 179
30
SOM-2079
1005-001
異常 ID 異常名、説明、要因および復帰方法
424321 Cnvr Positioning2 Error
An error was detected in transferring the PCB.
Por favor, verifique posicionamento da PCB no conveyor e continue a operação
424322 Cnvr Positioning2 Error
Speed reduction was not performed during transferring operation.
Please return the P.C.B. to the proper position when it is sitting between the
conveyors otherwise, remove the P.C.B. And, the P.C.B. detection sensor might
have had a wrong detection, so please check it to make detections correctly
424323 Cnvr Positioning2 Error
A servo error was found in the movement that the backup base was rising. The
backup jig and pins may be left under the transfer rail.
Cancel the error and perform zeroing operation after that, open the cover to
remove the left backup jig and pins under the transfer rail. Perform the setup
operation again to set the backup jig and the pins to the proper positions.
424324 Cnvr Positioning2 Error
Support pins /Jig were detected before the backup base starts to rise.
Remove the support pins / jig from the backup base. If the removong operation is
diffi
cult, perform the function to move the support pin changing position.
424325 Cnvr Positioning2 Error
Error data was transferred in the process of the bad mark transfer.
Pl
ease check the conformance between the transfer data and the pattern program
data.
425101 Output Cnvr Overtime
The PCB transport (carry in) from Cnvr Positioning2 did not end in prescribed
time.
Por favor, verifique posicionamento da PCB no conveyor e continue a operação
425102 Output Cnvr Overtime
The PCB transport (exhaust) to output machine did not end in prescribed time.
Por favor, verifique posicionamento da PCB no conveyor e continue a operação
425103 Output Cnvr Overtime
The movement to PCB receiving position did not end in prescribed time.
-----
425104 Output Cnvr Overtime
The movement to the arrangement position did not end in prescribed time.
-----
425105 Output Cnvr Overtime
The PCB transport (carry in) from Cnvr Positioning1 did not end in prescribed
time.
Por favor, verifique posicionamento da PCB no conveyor e continue a operação
425106 Output Cnvr Overtime
The reversal positioning operation did not end in prescribed time.
Por favor, verifique posicionamento da PCB no conveyor e continue a operação
425107 Output Cnvr Overtime
The conveyor upper cover by output side has opened.
Please close the cover. Production can be continued.
6.3 コンベア
31
SOM-2079
1005-001
異常 ID 異常名、説明、要因および復帰方法
425201 Output Cnvr PCB Detection
PCB's were at inlet and outlet of cnvr.
Por favor, verifique posicionamento da PCB no conveyor e continue a operação
425202 Output Cnvr PCB Detection
There is no PCB on the Cnvr The PCB fell while moving to the receiving position.
Please continue production after checking whether the P.C.B has fallen around a
co
nveyor. Moreover, please execute the zeroing operation of a pertinent conveyer
from the screen of maintenance/unit adjustment/conveyer when the width of the
conveyer has changed.
425203 Output Cnvr PCB Detection
There is no PCB on the Cnvr The PCB was removed.
-----
425204 Output Cnvr PCB Detection
There is a PCB on the Cnvr The PCB could not be discharged.
Por favor, verifique posicionamento da PCB no conveyor e continue a operação
425205 Output Cnvr PCB Detection
There is no PCB on the conveyer. After the PCB carrying in ended, it can not able
to be detected.
Por favor, verifique posicionamento da PCB no conveyor e continue a operação
425206 Output Cnvr PCB Detection
The PCB was detected by the conveyer entrance sensor.
Por favor, verifique posicionamento da PCB no conveyor e continue a operação
425207 Output Cnvr PCB Detection
The PCB was detected with the conveyer exit sensor.
Please confirm the P.C.B on the conveyer.
425208 Output Cnvr PCB Detection
The exhaust end board sensor of a conveyor exit detected the PCB
Please check the P.C.B on a conveyor.
425209 Output Cnvr PCB Detection
The exhaust end board sensor of a conveyor exit did not detect PCB during
discharge operation.
Please check the sensor.
425210 Output Cnvr PCB Detection
Manual bypass of the PCB was carried out in the state where a PCB is on a
conveyor.
Please remove the P.C.B carried out manual bypass. Production can be
continued.
425211 Output Cnvr PCB Detection
The PCB was not found in the proper position.
Please remove the P.C.B on a conveyor. Production can be continued.
425212 Output Cnvr PCB Detection
Manual bypass of the PCB was carried out.
Please remove the P.C.B carried out manual bypass. Production can be
continued.
6.3 コンベア
32
SOM-2079
1005-001
異常 ID 異常名、説明、要因および復帰方法
425213 Output Cnvr PCB Detection
PCB on a conveyer was removed in output sync / alternation output process.
Please do reproduction after making the P.C.B return to original state.
425214 Output Cnvr PCB Detection
The state of a PCB on conveyer changed in output sync / alternation output
process.
Please do reproduction after making the P.C.B return to original state.
425215 Output Cnvr PCB Detection
The PCB was detected with the conveyer entrance sensor.
Please return the P.C.B. to the proper position when it is sitting between the
conveyors otherwise, remove the P.C.B. And, the P.C.B. detection sensor might
have had a wrong detection, so please check it to make detections correctly
425216 Output Cnvr PCB Detection
The PCB was detected before carrying-in operation.
Restart the product operation after removing the P.C.B. when it is on the
conveyor.
425217 Output Cnvr PCB Detection
A PCB was detected with the conveyor entrance sensor upon completion of the
output operation.
After checking the P.C.B. on the conveyor, continue the product operation. If no
P.C.B. is there, remove the factor why the sensor was detected upon completion
of the output operation.
425218 Output Cnvr PCB Detection
A PCB was detected with the conveyor exit sensor upon completion of the output
operation.
After checking the P.C.B. on the conveyor, continue the product operation. If no
P.C.B. is there, remove the factor why the sensor was detected upon completion
of the output operation.
425219 Output Cnvr PCB Detection
A PCB was detected with the both sensors of the conveyor entrance and exit
upon completion of the output operation.
After checking the P.C.B. on the conveyor, continue the product operation. If no
P.C.B. is there, remove the factor why the sensor was detected upon completion
of the output operation.
425220 Output Cnvr PCB Detection
The machine let the END PCB remove from the conveyor.
Put the P.C.B. on the output conveyor and perform the "START". The product
operation can be continued that why the machine considers as if the P.C.B. put
was the end P.C.B..
425301 Output Cnvr Error
The carrying in operation was not able to begin.
-----
425302 Output Cnvr Error
The error was detected while carrying in was operating.
Por favor, verifi
que posicionamento da PCB no conveyor e continue a operação
6.3 コンベア