Communication and Control
One Wire Bus Function Control and Troubleshooting for Service Work
Student Guide (FSE) SIPLACE X Series and X4I
Communication and Control Edition 01/2009 EN
146
4-49: Subsystem control
Select
Get Versions
.
All available subsystems will be shown with their firmware versions and their CAN ID.
Doubleclick on the IO SUB (PA1) directory to open the 1 wire subdirectory. The following dialog will
appear:
4-50: One wire sub query structure with example of X4I
X Select
Query objects
and all subsystems on
the one wire bus at PA 1 will be displayed.
X The function
Init 1-Wire
is not required, as the
one wire bus system is initialized when the
machine is switched on. One wire bus
initialization is required for test purposes or in
cases of errors e.g. after disconnecting a
node.
NOTE:
The next pages show the assignment
of the lines from the adjacent window
Query Structure
for the relevant
hardware components of the one wire
bus (HF/HF3, X series, X4I)
Communication and Control
Function Control and Troubleshooting for Service Work One Wire Bus
Student Guide (FSE) SIPLACE X Series and X4I
Edition 01/2009 EN Communication and Control
147
Allocation of Subsystems to the Hardware Components
Assignment HF/HF3 PA1
Subsystem Hardware components Comments
Temperature, 1, coupler, 00 PCB: 1 wire trailing interface Trailing interface gantry 1
Temperature, 4, coupler, 00 PCB: 1 wire trailing interface Trailing interface gantry 4
NC, 4, coupler, 00 1 wire hub for NC Hub for NC at location 4 for NC row 1/2
NC, 1, coupler, 00 1 wire hub for NC Hub for NC at location 1 for NC row 1/2
Mainpath, 0, IO_2C, 01
Mainpath, 0, E2_512B, 01
I/O submodule I/O module, the-1-Wire-CAT5 board interface
will be integrated later into the I/O module
Temperature, 1, E2_512B, 81
Temperature, 1, E2_32B, 01
Temperature, 1, E2_512B, 61
Temperature, 1, temperature, 10
Temperature, 1, temperature, 11
Temperature, 1, IO_2C,01
Temperature sensors
Gantry 1
The two temperature sensors form a unit and
can only be replaced as a set. The gantry
recognition part can not be replaced.
Temperature, 4, E2_512B, 81
Temperature, 4, E2_32B, 01
Temperature, 4, E2_512B, 61
Temperature, 4, temperature, 10
Temperature, 4, temperature, 11
Temperature, 4, IO_2C,01
Temperature sensors
Gantry 4
The two temperature sensors form a unit and
can only be replaced as a set. The gantry
recognition part can not be replaced.
NC, 4, E2 32B, 81
NC, 4, AD, 03
NC, 4, AD, 15
NC, 4, AD, 16
1 wire hub NC on location 4 Shows, that the 1 wire hub is connected.
NC, 4, E2_32, 01
NC, 4, AD, 01
NC, 4, IO_8C, 01
Control board in NC
Gantry 4, only for C&P20A
NC
Control board of NC row 1
(only for C&P20A NC).
NC, 4, E2_32, 02
NC, 4, AD, 02
NC, 4, IO_8C, 02
Control board in NC
Gantry 4, only for C&P20A
NC
Control board of NC row 2
(only for C&P20A NC).
NC, 1, E2_32B, 81
NC, 1, AD, 03
NC, 1, AD, 15
NC, 1, AD, 16
1 wire hub NC on location 1 Shows that the 1 wire hub is connected.
NC, 1, E2_32B, 01
NC, 1, AD, 01
NC, 1, IO_8C, 01
Control board in NC
Gantry 1, only for C&P20A
NC
Control board of NC row 1
(only for C&P20A NC).
NC, 1, E2_32B, 02
NC, 1, AD, 02
NC, 1, IO_8C, 02
Control board in NC
Gantry 1, only for C&P20A
NC
Control board of NC row 2
(only for C&P20A NC).
Communication and Control
One Wire Bus Function Control and Troubleshooting for Service Work
Student Guide (FSE) SIPLACE X Series and X4I
Communication and Control Edition 01/2009 EN
148
Assignment X Series (up to SW 60x) PA1
Subsystem Hardware components Comments
NC, 1, coupler, 00 1-Wire CAT5 interface on
the I/O module
Temperature, 20, coupler, 00 1-Wire CAT5 interface on
the I/O module
NC, 4, coupler, 00 1-Wire CAT5 interface on
the I/O module
Mainpath, 0, IO_2C, 01
Mainpath, 0, E2_512B, 01
1-Wire CAT5 interface on
the I/O module
1-Wire-CAT5 board interface will be
integrated later into the I/O module
Temperature, 20, E2_32B, 01
temperature, 20, E2_512B, 61
Temperature, 20, temperature, 10
Temperature, 20, temperature, 11
Temperature, 1, IO_2C,01
Temperature sensors
Gantry 1
The two temperature sensors form a unit and
can only be replaced as a set. The gantry
recognition part can not be replaced.
Temperature, 20, E2_32B, 81
Temperature, 20, E2_512B, e1
Temperature, 20, temperature, 90
Temperature, 20, temperature, 91
Temperature, 20, IO_2C,81
Temperature sensors
gantry 4
The two temperature sensors form a unit and
can only be replaced as a set. The gantry
recognition part can not be replaced.
NC, 4, AD, 03
NC, 4, AD, 01
NC, 4, AD, 81
1 wire hub NC on location
4
Shows, that the 1 wire hub is connected.
NC, 4, E2_32B, 01
NC, 4, IO_8C, 01
NC, 4, AD, 01
Control board in NC
Gantry 4, only for
C&P20A NC
Control board of NC row 1
(only for C&P20A NC).
NC, 4, E2_32B, 81
NC, 4, IO_8C, 81
NC, 4, AD, 97
Control board in NC
Gantry 4, only for
C&P20A NC
Control board of NC row 2
(only for C&P20A NC).
NC, 1, AD, 01
NC, 1, AD, 03
NC, 1, AD, 81
1 wire hub NC on location
1
Shows, that the 1 wire hub is connected.
NC, 1, E2_32B, 01
NC, 1, IO_8C, 01
NC,1 AD, 15
Control board in NC
Gantry 1, only for
C&P20A NC
Control board of NC row 1
(only for C&P20A NC).
NC, 1, E2_32B, 81
NC, 1, IO_8C, 81
NC, 1, AD, 97
Control board in NC
Gantry 1, only for
C&P20A NC
Control board of NC row 2
(only for C&P20A NC).